Overview
Siemens · SIMATIC Bus Links
6ES7157-0AC82-0XA0 DP/PA Coupler
Siemens 6ES7157-0AC82-0XA0 is the standard non-Ex SIMATIC DP/PA Coupler for linking a PROFIBUS DP segment to PROFIBUS PA and supplying the connected PA fieldbus segment.
At a Glance
| Brand | Siemens |
|---|---|
| Model | 6ES7157-0AC82-0XA0 |
| Product Type | Standard non-Ex DP/PA coupler |
| Core Function | Couples PROFIBUS DP and PA physical layers while powering the PA segment |
| Application or Compatible Series | SIMATIC DP/PA Link systems |
Area Classification
Use this non-Ex version only where the connected PA equipment is installed outside hazardous areas.
Segment Load
Total all PA device currents and keep the segment within the one-ampere output limit.
Termination Setup
Set the internal PA termination according to whether the segment ends or continues at the coupler.
Product Overview
Siemens 6ES7157-0AC82-0XA0 is the standard non-Ex SIMATIC DP/PA Coupler for linking a PROFIBUS DP segment to PROFIBUS PA and supplying the connected PA fieldbus segment.
The coupler translates between the 45.45 kbaud DP physical layer and the 31.25 kbaud PA physical layer. A regulated thirty-one-volt output supplies the PROFIBUS PA segment with up to one ampere. Up to thirty-one certified PA devices can share the segment when the total current remains within the output budget.
Key Functions
DP-to-PA Physical Coupling
The coupler translates between the 45.45 kbaud DP physical layer and the 31.25 kbaud PA physical layer.
Integrated PA Power
A regulated thirty-one-volt output supplies the PROFIBUS PA segment with up to one ampere.
Transparent Segment Operation
Up to thirty-one certified PA devices can share the segment when the total current remains within the output budget.
Official Specifications
| PROFIBUS DP Rate | 45.45 kbaud |
|---|---|
| PROFIBUS PA Rate | 31.25 kbaud |
| Rated Supply Voltage | 24 V DC |
| Permitted Supply Range | 20.4 to 28.8 V DC |
| Supply Polarity Protection | Reverse-polarity protected |
| PA Output Voltage | 31 V DC ±1 V |
| PA Output Current | 1 A |
| Minimum Supply Hold-Up Time | 5 ms |
| Isolation from PROFIBUS DP | Galvanically isolated from the 24 V supply |
| Isolation from PROFIBUS PA | Galvanically isolated from the 24 V supply |
| Insulation Test Voltage | 500 V DC |
| Maximum Coupler Current at 24 V | 1.8 A |
| Typical Power Loss | 12 W |
| Maximum PA Devices | 31 |
| Status Indication | Yellow DP and PA LEDs with green ON LED |
| Enclosure Protection | IP20 |
| Horizontal Operating Temperature | -25 to 60 °C |
| Vertical Operating Temperature | -25 to 40 °C |
| Dimensions | 80 × 125 × 130 mm |
| Approximate Weight | 515 g |
Frequently Asked Questions
What fieldbus segment does 6ES7157-0AC82-0XA0 create?
The coupler links a PROFIBUS DP segment to a powered PROFIBUS PA segment.
Which bus rates must I use with 6ES7157-0AC82-0XA0?
Use 45.45 kbaud on the DP side and 31.25 kbaud on the PA side.
How many PA devices can I connect to 6ES7157-0AC82-0XA0?
Connect no more than thirty-one certified PA devices and keep their combined current at or below one ampere.
Can I use 6ES7157-0AC82-0XA0 for intrinsically safe field devices?
No, this standard non-Ex version is intended for PA equipment outside hazardous areas.
How should I terminate the PA cable at 6ES7157-0AC82-0XA0?
Enable the internal terminator only when the PA segment ends at the coupler and use external end termination when the cable continues.
Which Siemens replacement is specified for 6ES7157-0AC82-0XA0?
The compatible successor is the 0AC85 coupler, which can retain the existing bus module in the documented replacement arrangement.
How can I enable diagnostics after replacing 6ES7157-0AC82-0XA0 with the successor?
Assign the same PROFIBUS address above zero in both the replacement coupler and the engineering configuration.
Compatibility & Ordering Notes
Compatibility Checklist
- Use the non-Ex version only with PA field equipment located outside hazardous areas.
- Keep the PA device count at thirty-one or fewer and the total segment current at one ampere or less.
- The documented 0AC85 successor can retain the original bus module when used in the specified transparent replacement mode.