Siemens SIMATIC 6ES7157-0AC82-0XA0 DP/PA Coupler
Fabricator: Siemens
Condición: Nuevo
Plazo de Entrega: En Stock
Origo: Germania
Garantía: 12 Meses
Inscriptio electronica: [email protected]
whatsapp: +86-18150117685
- Conspectus
- Product Overview
- Key Functions
- Official Specifications
- Quaestiones Frequenter Rogatae
- Compatibility & Ordering Notes
- Hot Selling Models
- Producta commendata
Conspectus
Siemens · SIMATIC Bus Links
6ES7157-0AC82-0XA0 DP/PA Coupler
Siemens 6ES7157-0AC82-0XA0 est coupler DP/PA SIMATIC standard non-Ex pour relier un segment PROFIBUS DP à PROFIBUS PA et alimenter le segment de bus de terrain PA connecté.
Ad Primum Aspectum
| Nota | Siemens |
|---|---|
| Modellum | 6ES7157-0AC82-0XA0 |
| Typus Producti | Coupler DP/PA standard non-Ex |
| Functio principalis | Relie les couches physiques PROFIBUS DP et PA tout en alimentant le segment PA |
| Applicatio vel series compatibiles | Systèmes SIMATIC DP/PA Link |
Classification des zones
Utiliser cette version non-Ex uniquement là où les équipements PA connectés sont installés à l’extérieur des zones dangereuses.
Charge du segment
Sum all PA device currents and maintain the segment within the one-ampere output limit.
Termination Setup
Set the internal PA termination based on whether the segment ends or continues at the coupler.
Product Overview
Siemens 6ES7157-0AC82-0XA0 est coupler DP/PA SIMATIC standard non-Ex pour relier un segment PROFIBUS DP à PROFIBUS PA et alimenter le segment de bus de terrain PA connecté.
The coupler translates between the 45.45 kbaud DP physical layer and the 31.25 kbaud PA physical layer. A regulated thirty-one-volt output supplies the PROFIBUS PA segment with up to one ampere. Up to thirty-one certified PA devices can share the segment when the total current remains within the output budget.
Key Functions
DP-to-PA Physical Coupling
The coupler translates between the 45.45 kbaud DP physical layer and the 31.25 kbaud PA physical layer.
Integrated PA Power
A regulated thirty-one-volt output supplies the PROFIBUS PA segment with up to one ampere.
Transparent Segment Operation
Usque ad trīgintā ūnus certificātōs dispositīvōs PA permissum est segmentum cōnnectere dum summa cūrrentia intra finēs praebendae cūrrentiae manet.
Official Specifications
| Velocitas PROFIBUS DP | 45,45 kBaud |
|---|---|
| Velocitas PROFIBUS PA | 31,25 kBaud |
| Tensio nominalis supplicii | 24 V DC |
| Permissum Supplicationis Intervallum | 20,4 ad 28,8 V DC |
| Protectiō polaritātis suppliciōnis | Protectus contrā inversam polaritātem |
| Tensio exirens PA | 31 V DC ±1 V |
| Currente de output PA | 1 A |
| Tempus minimum tenendī suppliciōnis | 5 ms |
| Isolātiō ā PROFIBUS DP | Isolātiō galvānica ā suppliciōne 24 V |
| Isolātiō ā PROFIBUS PA | Isolātiō galvānica ā suppliciōne 24 V |
| Testis voltagii isolationis | 500 V DC |
| Cūrrens maximus accuplātoris ad 24 V | 1,8 A |
| Perditio potentiæ typica | 12 W |
| Dispositīvōs PA maximōs | 31 |
| Indicatio status | Flavus DP et PA LED cum viridi ON LED |
| Protectio Inclusis | IP20 |
| Temperatura operativa horizontalis | −25 ad 60 °C |
| Temperatura operativa verticalis | -25 ad 40 °C |
| Dimensiones | 80 × 125 × 130 mm |
| Pondus Approximatum | 515 g |
Quaestiones Frequenter Rogatae
Quod segmentum fieldbus creat 6ES7157-0AC82-0XA0?
Coupler coniungit segmentum PROFIBUS DP ad segmentum PROFIBUS PA alimentatum.
Quas velocitates bus debes uti cum 6ES7157-0AC82-0XA0?
Utere 45,45 kbaud in parte DP et 31,25 kbaud in parte PA.
Quot dispositiva PA ad 6ES7157-0AC82-0XA0 conectere possis?
Conecte non plus quam triginta unum certificata dispositiva PA et cura ut eorum currentis summa aequalis sit aut infra unum amperem.
Possumne uti 6ES7157-0AC82-0XA0 pro dispositivis campi intrinsece securis?
Non, haec versio standard non-Ex destinata est ad apparatus PA extra zonas periculosas.
Quomodo terminare debetis cationem PA ad 6ES7157-0AC82-0XA0?
Activare terminator internus solummodo cum segmentum PA finit ad coupler et uti terminationem externam extremam cum catio continuat.
Quod substitutum Siemens specificatur pro 6ES7157-0AC82-0XA0?
Successor compatibilis est coupler 0AC85, qui potest retinere modulum bus iam existentem in ordine substitutionis documentato.
Quomodo activare possum diagnosticos post substitutionem 6ES7157-0AC82-0XA0 per successor?
Attribuere eandem adressem PROFIBUS supra zero tam in coupler substitutionis quam in configuratione engineering.
Compatibility & Ordering Notes
Index Compatibilitatis
- Uti versionem non-Ex solummodo cum apparatus PA campi situatis extra zonas periculosas.
- Tenere il numero di dispositivi PA a trentuno o meno e la corrente totale del segmento a un ampere o meno.
- Il successore documentato 0AC85 può mantenere il modulo bus originale quando utilizzato nella specificata modalità di sostituzione trasparente.