Overview
- Use the selected RJ45, FastConnect or M12 BusAdapter and the corresponding network cabling.
- Configure from TIA Portal V14 or STEP 7 V5.5 SP4, or use the applicable GSDML description.
- Keep the 32-plus-16 module arrangement and address allocation within their individual limits.
- Observe the non-condensing environment, orientation limits and special altitude restrictions.
6ES7155-6AU01-0BN0 SIMATIC ET 200SP IM155-6 PN Standard Interface Module
A Standard PROFINET head module with 32 local I/O positions, ET-Connection expansion and support for three BusAdapter formats.
At a Glance
| Brand | Siemens |
|---|---|
| Model | 6ES7155-6AU01-0BN0 |
| Product Type | Distributed station head module |
| Core Function | Managing field I/O exchange on Industrial Ethernet |
| Application | ET 200SP modular stations |
Flexible cable connection
RJ45, FastConnect and M12 BusAdapter choices adapt the two-port network connection.
Extended installation environment
The non-condensing operating range extends down to −30 °C with the stated installation-orientation limits.
Modular station management
Configuration datasets and single hot swapping support the chosen combination of local and remote I/O.
Product Overview
6ES7155-6AU01-0BN0 forms the PROFINET head of an ET 200SP station.
The FS03 and V4.2 hardware/firmware arrangement provides configuration control, single hot swapping and Shared Device services, with an extended low-temperature installation range under non-condensing conditions.
Key Functions
Flexible cable connection
RJ45, FastConnect and M12 BusAdapter choices adapt the two-port network connection.
Extended installation environment
The non-condensing operating range extends down to −30 °C with the stated installation-orientation limits.
Modular station management
Configuration datasets and single hot swapping support the chosen combination of local and remote I/O.
Official Specifications
| Rated supply and range | 24 V DC; 19.2–28.8 V |
|---|---|
| Supply current | 450 mA rated; 550 mA maximum |
| Maximum inrush | 3.7 A with I²t of 0.09 A²s |
| Typical dissipation | 1.9 W |
| Power interruption bridging | 10 ms |
| Supported field modules | 32 ET 200SP modules and 16 ET 200AL modules maximum |
| Address capacity | 256 bytes per module in each direction; 512 bytes per station maximum |
| Maximum submodule count | 256 |
| Network ports | Two switched 100BASE-TX ports via BusAdapter |
| BusAdapter variants | BA 2x RJ45, BA 2x FC and BA 2x M12 |
| IRT send cycle | 250 µs to 4 ms on a 125 µs frame |
| Shared Device controllers | 2 maximum |
| Ring redundancy | MRP client; MRPD and S2 are not available |
| Supply protection | Reverse-polarity and short-circuit protection |
| Ethernet electrical separation | Isolated from other circuits; 1,500 V AC type test |
| Additional isolation type test | 707 V DC |
| Horizontal operating temperature | −30 to +60 °C, without condensation |
| Vertical operating temperature | −30 to +50 °C, without condensation |
| Maximum installation altitude | 5,000 m; installation restrictions apply above 2,000 m |
| Dimensions and weight | 50 × 117 × 74 mm; approximately 147 g excluding BusAdapter |
Frequently Asked Questions
Can I use GSDML engineering for 6ES7155-6AU01-0BN0?
The applicable device-description version is GSDML V2.35.
Can I fit an M12 network BusAdapter to 6ES7155-6AU01-0BN0?
BA 2x M12 is included among the supported BusAdapter options.
How much maximum supply current should I allow for 6ES7155-6AU01-0BN0?
Allow for the specified maximum supply current of 550 mA.
Can 6ES7155-6AU01-0BN0 bridge a ten-millisecond supply interruption?
The specified stored-energy bridging time is 10 ms.
Can I install 6ES7155-6AU01-0BN0 below freezing in a dry cabinet?
Operation down to −30 °C is permitted provided that no condensation occurs.
Can I apply the ordinary installation conditions to 6ES7155-6AU01-0BN0 at 4,000 m altitude?
Installations above 2,000 m are subject to the additional altitude restrictions.
Can I exchange station data with 6ES7155-6AU01-0BN0 using Modbus TCP?
The interface does not support Modbus TCP.