Siemens 6ES7151-7AA00-0AB0 SIMATIC ET 200S IM151-7 CPU Interface Module
Manufacturer: Siemens
Condition: Brand New
Lead Time: In Stock
Origin: Germany
Warranty: 12 Months
Email: [email protected]
whatsApp: +86-18150117685
- Overview
- Hot Selling Models
- Recommended Products
Overview
- Use STEP 7 V5.1 or later and retain the original station hardware configuration.
- Configure the PROFIBUS interface as a DP slave rather than an MPI connection.
- Keep local I/O addressing within the 1,536-byte input and output address areas.
- Size the connected backplane load within the 700 mA limit.
6ES7151-7AA00-0AB0 SIMATIC ET 200S IM151-7 CPU Interface Module
An IM151-7 CPU with 24 kB work memory, an integrated PROFIBUS DP slave interface and support for up to 63 station modules.
At a Glance
| Brand | Siemens |
|---|---|
| Model | 6ES7151-7AA00-0AB0 |
| Product Type | CPU interface module |
| Core Function | Executing local control programs and exchanging distributed I/O data |
| Application | ET 200S stations |
Run control close to the I/O
The integrated CPU executes bit, word, integer and floating-point instructions independently of cyclic master data exchange.
Integrate with a PROFIBUS master
The isolated RS485 port supports DP slave operation, S7 communication and direct slave-to-slave exchange at rates up to 12 Mbit/s.
Build a modular station
Up to 63 modules can be connected in one station, with separate process images for inputs and outputs.
Product Overview
6ES7151-7AA00-0AB0 combines a local programmable controller with the head interface of an ET 200S station. Its integrated RS485 PROFIBUS interface operates as a DP slave while the CPU executes the station program.
The controller provides fixed-size input and output process images, retentive data and S7 programming resources for distributed control. STEP 7 engineering connects through the PROFIBUS interface.
Key Functions
Run control close to the I/O
The integrated CPU executes bit, word, integer and floating-point instructions independently of cyclic master data exchange.
Integrate with a PROFIBUS master
The isolated RS485 port supports DP slave operation, S7 communication and direct slave-to-slave exchange at rates up to 12 Mbit/s.
Build a modular station
Up to 63 modules can be connected in one station, with separate process images for inputs and outputs.
Official Specifications
| Rated supply and operating range | 24 V DC; 20.4–28.8 V DC |
|---|---|
| Maximum supply current | Approximately 250 mA from 1L+ |
| Maximum inrush current | 3.5 A |
| Backplane power capacity | 5 V DC, maximum 700 mA |
| Typical power loss | 3.3 W |
| Integrated work memory | 24 kB, non-expandable |
| Bit and word instruction times | 0.3 µs for bit operations; 1 µs for word operations |
| Arithmetic execution times | 2 µs for fixed-point operations; 50 µs for floating-point operations |
| Timer and counter instruction time | 12 µs typical |
| Function block resources | 128 FBs and 128 FCs; maximum 8 kB per block |
| Data block resources | 127 DBs; DB0 reserved; maximum 8 kB per block |
| S7 timer and counter resources | 128 timers and 64 counters |
| Maximum retentive data | 4,736 bytes including timers, counters and flags |
| Flag memory | 256 bytes |
| Input and output address areas | 1,536 bytes each |
| Fixed process images | 128 input bytes and 128 output bytes |
| DP transfer memory | 64 input bytes and 64 output bytes |
| Maximum bus rate | 12 Mbit/s |
| Operating temperature | 0–60 °C |
| Dimensions and approximate weight | 60 × 119.5 × 75 mm; 200 g |
Frequently Asked Questions
Can 6ES7151-7AA00-0AB0 execute a local program while connected to a DP master?
The integrated CPU runs the local station program while its PROFIBUS interface operates as a DP slave.
Which STEP 7 release can configure 6ES7151-7AA00-0AB0?
Engineering requires STEP 7 V5.1 or later.
How many modules can follow 6ES7151-7AA00-0AB0 in an ET 200S station?
The station supports up to 63 modules.
Can I enlarge the integrated work memory in 6ES7151-7AA00-0AB0?
The integrated 24 kB work memory cannot be expanded.
How much cyclic transfer memory is available at the DP interface of 6ES7151-7AA00-0AB0?
The DP interface provides 64 bytes for inputs and 64 bytes for outputs.
Can I adjust the input process image size on 6ES7151-7AA00-0AB0?
The input process image is fixed at 128 bytes.
Can 6ES7151-7AA00-0AB0 communicate directly with another DP slave?
The PROFIBUS interface supports direct slave-to-slave data exchange.