Get a Free Quote

Our representative will contact you soon.
Email
Name
Company Name
Message
0/1000
siemens 6es7147 5jd00 0ba0 simatic et 200al cm 4xio link 4xm12-0

For SIEMENS

Home >  Products >  For SIEMENS

Siemens 6ES7147-5JD00-0BA0 SIMATIC ET 200AL CM 4xIO-Link 4xM12

Manufacturer: Siemens
Condition: Brand New
Lead Time: In Stock
Origin: Germany
Warranty: 12 Months

  • Overview
  • Hot Selling Models
  • Recommended Products
Overview

SIEMENS SIMATIC ET 200AL

6ES7147-5JD00-0BA0 SIMATIC ET 200AL CM 4xIO-Link 4xM12

Connect four IO-Link devices through M12 ports and integrate their process data, parameters and diagnostics into an ET 200AL station.

At a Glance

Brand Siemens
Model 6ES7147-5JD00-0BA0
Product Type IO-Link communication module
Core Function Connect intelligent field devices
Application ET 200AL distributed I/O stations

Four field-device ports

Each M12 port supports IO-Link operation and configurable standard I/O modes.

Separate supply groups

1L+ powers the electronics and sensors, while 2L+ supplies the additional device circuit.

Device parameter storage

Parameter memory and master backup support device and module replacement.

Product Overview

6ES7147-5JD00-0BA0 expands an ET 200AL station with four IO-Link master ports for intelligent sensors and actuators. IO-Link V1.0 and V1.1 devices communicate at COM1, COM2 or COM3 speeds through the same field connection format.

The module exchanges up to 32 bytes of input and 32 bytes of output process data per port, stores device parameters and provides configurable diagnostics for the supply and field connections.

Ordering focus: Check each device port type, process-data length and supply-current requirement before assigning the IO-Link ports.
Key Functions

Integrate IO-Link process and diagnostic data

Four simultaneously controllable ports support IO-Link communications and configurable digital input or output operation.

Restore field-device parameters

Device parameter memory of 2 kbytes per port and the IO_LINK_MASTER function block support parameter backup for service tasks.

Build distributed field wiring

M12 field sockets and M8 supply and ET-Connection interfaces suit compact station wiring with an unshielded IO-Link cable length up to 20 m.

Official Specifications
IO-Link Port Capacity 4 simultaneously controllable ports; IO-Link V1.0 and V1.1
Communication Speeds 4.8 kbaud COM1; 38.4 kbaud COM2; 230 kbaud COM3
Process Data per Port 32 bytes input and 32 bytes output
Module Process-Data Size 132 bytes input and 128 bytes output
Device Parameter Memory 2 kbytes per port
Nominal Supply and Permitted Range 1L+ and 2L+: 24 V DC, 20.4 to 28.8 V DC
No-Load Current 40 mA
Maximum Supply Current 4 A from 1L+ and 4 A from 2L+
Sensor-Supply Current Maximum 1.4 A total across all ports
Port B Additional Supply Maximum 1.6 A total across all ports
Standard Digital Output Rating Maximum 100 mA per configured DQ
Typical Power Dissipation 2.6 W
Maximum IO-Link Cable Length 20 m, unshielded
Field and Supply Connections 5-pole M12 I/O; 4-pole M8 supply; shielded 4-pin M8 ET-Connection
Operating Ambient Temperature −30 to +55 °C
Isolation Type-Test Voltage 707 V DC
Housing Dimensions 30 × 159 × 40 mm (W × H × D)
Approximate Weight 145 g
Frequently Asked Questions

Can 6ES7147-5JD00-0BA0 connect IO-Link V1.0 and V1.1 sensors in one station?

Yes, the master supports both protocol versions and provides four independently usable ports.

Does 6ES7147-5JD00-0BA0 support Separate supply groups for mobile equipment?

The maximum permitted unshielded cable length between the module and an IO-Link device is 20 m.

Can I configure a port of 6ES7147-5JD00-0BA0 as an ordinary digital output?

Yes, a port can operate in DQ mode with a maximum output current of 100 mA.

How much process data should I reserve per port on 6ES7147-5JD00-0BA0?

Each port supports up to 32 bytes of input and 32 bytes of output process data.

Which STEP 7 versions can configure 6ES7147-5JD00-0BA0?

Configuration is available from TIA Portal V13 SP1 or STEP 7 V5.5 SP4 Hotfix 3.

How can I back up the master configuration before replacing 6ES7147-5JD00-0BA0?

Use the IO_LINK_MASTER function block to back up the master parameters.

What supply limit applies when connecting Port B devices to 6ES7147-5JD00-0BA0?

The additional device supply for Port B connections is limited to a total current of 1.6 A across all ports.

Compatibility & Ordering Notes
Before ordering 6ES7147-5JD00-0BA0: Select IO-Link devices and M12 cables for the required Port A or Port B wiring, then check both supply groups and the controller process-data allocation.

Compatibility Checklist for 6ES7147-5JD00-0BA0

  • Allocate 132 input bytes and 128 output bytes when using the full module data range.
  • Keep sensor and additional-device currents within their separate total limits.
  • Use the required GSD revision 5 or GSDML V2.3.1 where GSD engineering is used.
  • Plan master backup and device parameter handling before replacing the module.
Hot Selling Models
3RV2011-0EA25
CPE10-M1BH-3GLS-M5
45-02 996-09396
MRR90107
NZM1/2-XAGK
BCS0099 BCS S42SS02-GPCFAG-S49G
CP6206.500
EL1004
EL1014
M22-PV/KC02/IY
4K.10 E-No910-304-105- + HS E-No910-304-551-00
PN-98098-2
BOS00WF BOS 12M-PA-LE10-S4
CSJ055A-L
46/4.6-S12 50102421

Get a Free Quote

Our representative will contact you soon.
Email
Name
Company Name
Message
0/1000
email goToTop

Evolo Automation is not an authorized distributor unless otherwise specified, representative, or affiliate of the manufacturer of this product. All trademarks and documents are the property of their respective owners and are provided for identification and informational.