- Use a supported 30 mm ET 200S terminal module.
- Supply the control input from the appropriate fail-safe output.
- Apply the contact voltage, current and switching-frequency limits to the connected load.
- Include the required process feedback and safety logic for standard load-group shutdown.
- Use the status LED only as local indication.
6ES7138-4FR00-0AA0 SIMATIC ET 200S 1F-RO Safety Relay Module
A 30 mm-wide 1F-RO module with one relay output, two normally open contacts and a 5 A rated output current for 24 V DC or 24–230 V AC loads.
At a Glance
| Brand | Siemens |
|---|---|
| Model | 6ES7138-4FR00-0AA0 |
| Product Type | Fail-safe relay electronics module |
| Core Function | Safety-related switching through relay contacts |
| Application | ET 200S safety I/O assemblies |
Relay load switching
The output combines two normally open contacts with electrical separation from the control circuit.
Fail-safe control
An appropriate fail-safe output drives the relay module for the required safety architecture.
Terminal-module selection
The supported bases include TM-E30S44-01, TM-E30C44-01, TM-E30S46-A1 and TM-E30C46-A1.
Product Overview
6ES7138-4FR00-0AA0 provides relay switching within an ET 200S station, separating the field load circuit from its 24 V DC control supply.
Category 4, SIL 3 and PL e can be achieved when the module is controlled by an appropriate fail-safe output and incorporated into the required safety system.
Key Functions
Switch separate load circuits
The relay output provides two normally open contacts for DC or AC loads within the stated switching ratings.
Integrate safety-related shutdown
The module can be combined with an ET 200S F-DO output for safety-related shutdown of standard load groups.
Observe output indication
A green output-status LED provides local indication; it must not be evaluated as a safety-related signal.
Official Specifications
| Control Voltage | 24 V DC, supplied from a fail-safe output |
|---|---|
| Load-Voltage Range | 24 V DC or 24–230 V AC |
| Relay Contact Arrangement | 1 output with 2 normally open contacts |
| Rated Output Current | 5 A |
| Minimum Load Current | 5 mA |
| Maximum Control-Supply Current | 100 mA without load |
| Maximum Backplane-Bus Current | 10 mA from 3.3 V DC |
| Typical Power Dissipation | 2.1 W |
| Maximum Address Space | 1 byte; 2 bits with packing |
| Maximum Switching Frequency | 2 Hz for resistive loads; 0.1 Hz for inductive loads |
| Maximum Field-Cable Length | 200 m, shielded or unshielded |
| Isolation Arrangement | Output contacts isolated from the backplane bus and control supply |
| Integrated Short-Circuit Protection | None |
| Dimensions | 30 × 81 × 52 mm (W × H × D) |
| Approximate Weight | 90 g |
Frequently Asked Questions
Which base can I use beneath 6ES7138-4FR00-0AA0?
The supported terminal modules are TM-E30S44-01, TM-E30C44-01, TM-E30S46-A1 and TM-E30C46-A1.
Can 6ES7138-4FR00-0AA0 disconnect an AC load as well as a DC load?
The relay contacts accommodate 24 V DC or 24 to 230 V AC loads within their specified current limits.
Does fitting 6ES7138-4FR00-0AA0 alone create a SIL 3 safety circuit?
Achieving SIL 3 requires control by an appropriate fail-safe output and the corresponding complete safety architecture.
May I use the green output LED on 6ES7138-4FR00-0AA0 as a safety feedback signal?
The status LED is not designed for safety-related evaluation.
How quickly may 6ES7138-4FR00-0AA0 cycle an inductive load?
The maximum switching frequency for an inductive load is 0.1 Hz.
Can 6ES7138-4FR00-0AA0 protect its load circuit against a short circuit?
The relay output does not include short-circuit protection.
How far can I run the output wiring from 6ES7138-4FR00-0AA0?
The maximum cable length is 200 m for either shielded or unshielded wiring.