Get a Free Quote

Our representative will contact you soon.
Email
Name
Company Name
Message
0/1000
siemens 6es7134 7sd00 0ab0 simatic et 200isp 4 ai tc analog input module-0

For SIEMENS

Home >  Products >  For SIEMENS

Siemens SIMATIC ET 200iSP 4 AI TC Analog Input Module 6ES7134-7SD00-0AB0

Manufacturer: Siemens
Condition: Brand New
Lead Time: In Stock
Origin: Germany
Warranty: 12 Months

  • Overview
  • Product Overview
  • Key Functions
  • Official Specifications
  • Frequently Asked Questions
  • Compatibility & Ordering Notes
  • Hot Selling Models
  • Recommended Products
Overview

Siemens • SIMATIC ET 200iSP

6ES7134-7SD00-0AB0 SIMATIC ET 200iSP 4 AI TC Analog Input Module

The SIMATIC ET 200iSP 4 AI TC module provides four intrinsically safe analog inputs for thermocouple and voltage measurement with configurable linearization and diagnostics.

At a Glance

Brand Siemens
Model 6ES7134-7SD00-0AB0
Product Type Four-channel intrinsically safe thermocouple input module
Core Function Measures thermocouple and voltage signals in hazardous-area process systems
Application or Compatible Series ET 200iSP installations requiring intrinsically safe temperature measurement

Exact Identification

Match 6ES7134-7SD00-0AB0 character by character and confirm the complete SIMATIC ET 200iSP 4 AI TC Analog Input Module designation.

Interface Arrangement

Confirm the installed supply, ports, field connections and required accessories before wiring the replacement.

Configuration Check

Preserve the approved engineering project, network parameters and application data used by the installed system.

Product Overview

The SIMATIC ET 200iSP 4 AI TC module provides four intrinsically safe analog inputs for thermocouple and voltage measurement with configurable linearization and diagnostics.

Four channels acquire thermocouple or voltage signals in the ET 200iSP station. Configured linearization supports common E, N, J, K, L, S, R, B, T and U thermocouples. Intrinsically safe circuits support the certified Ex installation when all associated conditions are met.

Ordering focus: confirm the exact 4 AI TC article number, ET 200iSP station, thermocouple types, compensation method, Ex certificate conditions, terminal assignments, loop parameters and diagnostics.
Key Functions

Four Temperature Inputs

Four channels acquire thermocouple or voltage signals in the ET 200iSP station.

Broad Thermocouple Support

Configured linearization supports common E, N, J, K, L, S, R, B, T and U thermocouples.

Hazardous-Area Capability

Intrinsically safe circuits support the certified Ex installation when all associated conditions are met.

Official Specifications
Analog Inputs 4
Supported Sensors Thermocouples and voltage signals
Thermocouple Types E, N, J, K, L, S, R, B, T and U
Characteristic Linearization Provided
Diagnostic Alarm Parameterizable
Limit Alarm Parameterizable
Wire-Break Detection R greater than 1.7 kohm
Open-Circuit Voltage Uo 5.9 V maximum
Short-Circuit Current Io 15 mA maximum
Output Power Po 23 mW maximum
External Capacitance Co, IIC 43 uF maximum
External Inductance Lo, IIC 100 mH maximum
Channel-to-Power-Bus Isolation Provided
Channel-to-Backplane Isolation Provided
Degree of Protection IP30
Electrical Connection Screw or spring terminal
Dimensions W x H x D 30 x 129 x 136.5 mm
Approximate Weight 230 g
ATEX Certificate KEMA 04 ATEX 1246
IECEx Certificate IECEx KEM 05.0008
Frequently Asked Questions

How many thermocouples can connect to 6ES7134-7SD00-0AB0?

The module provides four analog input channels for thermocouple or voltage measurement.

Which thermocouple types are supported by 6ES7134-7SD00-0AB0?

Configure the required E, N, J, K, L, S, R, B, T or U characteristic.

Can 6ES7134-7SD00-0AB0 be installed in an intrinsically safe circuit?

Yes; the complete loop, enclosure and associated apparatus must comply with the certified Ex parameters.

How does 6ES7134-7SD00-0AB0 detect an open sensor circuit?

Wire-break diagnostics operate when the configured circuit resistance exceeds the stated threshold.

What should be checked before changing 6ES7134-7SD00-0AB0?

Verify the Ex documentation, terminal assignment, thermocouple type, compensation method, barriers and grounding.

Can limit alarms be configured on 6ES7134-7SD00-0AB0?

Yes; parameterizable limit alarms are available for the measured channels.

What must be tested after installing 6ES7134-7SD00-0AB0?

Validate all four channels with known temperature signals and confirm compensation, diagnostics, alarms and intrinsic-safety records.

Compatibility & Ordering Notes
Before ordering 6ES7134-7SD00-0AB0: confirm the exact 4 AI TC article number, ET 200iSP station, thermocouple types, compensation method, Ex certificate conditions, terminal assignments, loop parameters and diagnostics.

Compatibility Checklist

  • Use only within the certified ET 200iSP and Ex installation design.
  • Match thermocouple type, polarity and compensation settings per channel.
  • Verify Uo, Io, Po, Co and Lo against every connected intrinsically safe loop.
Hot Selling Models
1281BIL224
3SU1106-6AA60-1AA0
3SB3 244-6AA50-0CC0
7000-17041-2920150
GWB44
ETD-BL-1T-OFF-CC-10S
ABB ESB25-40N
FAZ-C2/2
CA3KN223BD
efector100 IF5539 ​​IFB3004-BPKG/US-100-DPS
70/00442789
WAGO 750-600
100KMCH
AXLSESC-A 1088134
LA1LB001

Get a Free Quote

Our representative will contact you soon.
Email
Name
Company Name
Message
0/1000
email goToTop