Overview
SIMATIC ET 200S

6ES7134-4NB01-0AB0 SIMATIC ET 200S Two-Channel Thermocouple High Feature Module

A narrow 2AI TC High Feature module with internal or external cold-junction compensation, integrating conversion and selectable smoothing.

At a Glance

Brand Siemens
Model 6ES7134-4NB01-0AB0
Product Type Thermocouple analog input module
Core Function Converting temperature-sensor signals
Application Modular ET 200S I/O stations

Selectable thermocouple acquisition

Ten thermocouple types and a bipolar millivolt range support different field sensors.

Cold-junction compensation

Internal compensation uses the designated AT terminal modules, while external compensation uses one compensating box per channel.

Configurable measurement filtering

Four smoothing stages trade response time for the selected level of digital filtering.

Product Overview

6ES7134-4NB01-0AB0 acquires thermocouple or low-level voltage measurements in an ET 200S station.

Configurable sensor linearization, temperature units and digital smoothing adapt the two-channel module to the field measurement, while diagnostic functions cover sensor wire breaks and range violations.

Ordering focus: Match the thermocouple type, cold-junction compensation terminal module, signal wiring and required update response.
Key Functions

Selectable thermocouple acquisition

Ten thermocouple types and a bipolar millivolt range support different field sensors.

Cold-junction compensation

Internal compensation uses the designated AT terminal modules, while external compensation uses one compensating box per channel.

Configurable measurement filtering

Four smoothing stages trade response time for the selected level of digital filtering.

Official Specifications
Analog input count 2
Input voltage range −80 to +80 mV
Thermocouple types B, C, E, J, K, L, N, R, S and T
Input resistance 1 MΩ for the voltage and thermocouple ranges
Conversion resolution 15 bits plus sign; 16 bits including sign with overrange
Integrating conversion 16.7 or 20 ms integration for 60 or 50 Hz interference suppression
Basic conversion time 66 or 80 ms per channel; wire-break testing adds conversion time
Module cycle time Number of active channels multiplied by the basic conversion time
Digital smoothing None: 1× cycle; low: 4×; medium: 32×; high: 64×
Temperature engineering units Celsius or Fahrenheit
Supply 24 V DC from the power module
Maximum current demand 30 mA from L+ and 10 mA from the 3.3 V backplane
Typical dissipation 0.6 W
Input address space 4 bytes
Maximum shielded signal cable 50 m
Voltage error limits ±0.05% basic at 25 °C; ±0.1% operational over the temperature range
Diagnostics Thermocouple wire break, group error and overflow/underflow; red SF indicator
Input isolation Channels isolated from the backplane and L+; no channel-to-channel isolation
Isolation test voltage 500 V DC
Dimensions and approximate mass 15 × 81 × 52 mm (W × H × D); 40 g
Frequently Asked Questions

Which terminal modules enable internal cold-junction compensation for 6ES7134-4NB01-0AB0?

Use a TM-E15S24-AT or TM-E15C24-AT terminal module for internal compensation.

Can I share one external compensating box between both channels of 6ES7134-4NB01-0AB0?

External cold-junction compensation requires one compensating box per channel.

Can 6ES7134-4NB01-0AB0 measure a low-level voltage instead of a thermocouple?

The module includes a −80 to +80 mV input range.

Can I display temperatures from 6ES7134-4NB01-0AB0 in Fahrenheit?

The temperature engineering unit can be configured as Celsius or Fahrenheit.

How much response delay does the high smoothing setting add on 6ES7134-4NB01-0AB0?

The high smoothing setting corresponds to 64 times the module cycle time.

Are the two sensor channels of 6ES7134-4NB01-0AB0 isolated from one another?

The channels are not isolated from each other, although they are isolated from the backplane and load supply.

How far may I run a shielded thermocouple cable to 6ES7134-4NB01-0AB0?

The specified maximum shielded signal-cable length is 50 m.

Compatibility & Ordering Notes
Before ordering 6ES7134-4NB01-0AB0: Match the thermocouple type, cold-junction compensation terminal module, signal wiring and required update response.

Before installation

  • Select the thermocouple characteristic or millivolt range to match the connected sensor.
  • Use the designated AT terminal module for internal compensation or separate external compensating boxes.
  • Include active-channel count, filtering and wire-break diagnostics in the update-time calculation.
  • Use shielded signal wiring and retain the correct ET 200S power-module arrangement.
Hot Selling Models
PZE /5 24VDC 4S 1Ö 474910
DFSP-20-20-PS-PA
6ES5308-3UA12 6ES5376-1AA11
Allen Bradley 1771-OBD
PC71UD13C315TF
75-112
6ES5497-4UA12
NG1000-2-0
6ES5927-3SA12
E1501W2 BR834/2
FRBmM-C13 170618
3011365-0-2130000
6ES5465-3AA13
6ES5470-4UA11
3RV2021-1BA10

Get a Free Quote

Our representative will contact you soon.
Email
Name
Company Name
Message
0/1000
email goToTop

Evolo Automation is not an authorized distributor unless otherwise specified, representative, or affiliate of the manufacturer of this product. All trademarks and documents are the property of their respective owners and are provided for identification and informational.