Siemens 6ES7132-7RD22-0AB0 SIMATIC ET 200iSP 4 DO 17.4 V/40 mA Shutdown H Module
Manufacturer: Siemens
Condition: Brand New
Lead Time: In Stock
Origin: Germany
Warranty: 12 Months
Email: [email protected]
whatsApp: +86-18150117685
- Overview
- Hot Selling Models
- Recommended Products
Overview
- Keep the shutdown-signal circuits for H and L variants separate.
- Use only the specified same-module channel pairs for parallel output operation.
- Connect each module directly to the shutdown source when hot swapping with actuator shutdown enabled.
- When replacing an earlier 7RD21 version, change the terminal coding element to the correct successor coding.
SIEMENS SIMATIC ET 200iSP
6ES7132-7RD22-0AB0 SIMATIC ET 200iSP 4 DO 17.4 V/40 mA Shutdown H Module
Operate four intrinsically safe field outputs with a high-active shutdown input that deactivates all channels independently of the output process image.
At a Glance
| Brand | Siemens |
|---|---|
| Model | 6ES7132-7RD22-0AB0 |
| Product Type | Intrinsically safe digital output electronics |
| Core Function | Operate field actuators with group shutdown |
| Application | ET 200iSP distributed process I/O |
Field actuator outputs
Four outputs serve suitable Ex i solenoid valves, DC relays and actuators.
High-active group shutdown
An intrinsically safe HIGH signal deactivates all four outputs together.
Paired output loading
Approved channel pairs can be connected in parallel on the same module for increased actuator current.
Product Overview
6ES7132-7RD22-0AB0 is a four-channel ET 200iSP output module with the SHUT DOWN H function. The 17.4 V/40 mA output characteristic supports compatible intrinsically safe field actuators, with an additional input for simultaneous actuator shutdown.
The shutdown function acts on all output channels without changing the output process image, and configurable diagnostics report channel faults; two approved outputs on the same module can be paralleled for a higher-current actuator.
Key Functions
Switch intrinsically safe actuator circuits
Four digital outputs control compatible Ex i solenoid valves, relays and actuators within the output characteristic and circuit limits.
Deactivate every output through one signal
The high-active intrinsically safe shutdown input disables channels 0 through 3 independently of the output process image.
Increase available actuator current with approved pairs
Channels 0 and 1 or channels 2 and 3 can be connected in parallel on the same module using the specified jumper and load terminals.
Official Specifications
| Output Arrangement | 4 transistor output channels plus 1 intrinsically safe high-active shutdown input |
|---|---|
| No-Load Output Voltage | 17.4 V DC |
| Output Characteristic Break Point | 10.7 V at 40 mA for one output; 80 mA with an approved parallel pair |
| Internal Output Resistance | 167 Ω |
| Power-Bus Current Consumption | Typical 380 mA; maximum 400 mA |
| Module Power Dissipation | 2.8 W |
| Maximum Field Cable Length | 500 m, shielded or unshielded |
| Electrical Isolation | Outputs isolated from backplane, power bus and shutdown input; no isolation between output channels |
| Permitted Circuit Potential Difference | 60 V DC or 30 V AC |
| Short-Circuit Detection Threshold | Load plus line resistance below 80 Ω for one output or below 40 Ω for a parallel pair |
| Wire-Break Detection | Load plus line resistance above 10 kΩ and current below 100 µA |
| Maximum Output Residual Current | 25 µA |
| Maximum Switching Frequency | 100 Hz with resistive loads; 2 Hz with inductive loads |
| Shutdown Input Intrinsic-Safety Limits | Ui 28 V; Pi 1.2 W; Ci 3 nF; Li 0 mH |
| Minimum Shutdown Switching Signal | 10.5 V and 2 mA |
| Maximum Shutdown-Signal Current | 8 mA per module when supplied through a safety barrier |
| Local Status Indicators | Green output LED per channel and red SF group-fault LED |
| Dimensions and Approximate Weight | 30 × 129 × 136.5 mm (W × H × D); 255 g |
Frequently Asked Questions
Can I shut down every channel of 6ES7132-7RD22-0AB0 through one field signal?
Yes, a high-active intrinsically safe switching signal at the shutdown input deactivates all four outputs.
Does 6ES7132-7RD22-0AB0 support High-active group shutdown for mobile equipment?
No, actuator shutdown does not affect the output process image.
Which channels can I parallel on 6ES7132-7RD22-0AB0 for a higher-current actuator?
Only channels 0 and 1 or channels 2 and 3 on the same module may be connected in parallel using the specified terminal arrangement.
Which terminal modules can carry 6ES7132-7RD22-0AB0?
The electronics can be mounted on TM-IM/EM 60S, TM-IM/EM 60C, TM-EM/EM 60S or TM-EM/EM 60C terminal modules.
Will 6ES7132-7RD22-0AB0 operate if no intrinsically safe shutdown signal is applied?
Yes, the H-shutdown module operates with its normal functionality when no shutdown signal is applied.
How should I wire the shutdown signal if I plan to hot-swap 6ES7132-7RD22-0AB0?
Connect each module directly to the shutdown-signal source because a daisy-chained signal path through the terminals is interrupted when a module is removed.
Is the no-load voltage of 6ES7132-7RD22-0AB0 also available at the rated 40 mA operating point?
No, the output characteristic has its 40 mA break point at 10.7 V rather than the 17.4 V no-load voltage.