Get a Free Quote

Our representative will contact you soon.
Email
Name
Company Name
Message
0/1000
siemens 6es7132 6gd51 0ba0 et 200sp rq co 4 channel signal relay module-0

For SIEMENS

Home >  Products >  For SIEMENS

Siemens 6ES7132-6GD51-0BA0 ET 200SP RQ CO 4-Channel Signal Relay Module

Manufacturer: Siemens
Condition: Brand New
Lead Time: In Stock
Origin: Germany
Warranty: 12 Months

  • Overview
  • Hot Selling Models
  • Recommended Products
Overview
SIMATIC ET 200SP

6ES7132-6GD51-0BA0 ET 200SP RQ CO 4-Channel Signal Relay Module

A four-channel changeover-relay module for 24 V AC/DC signals up to 2 A per channel, with supply-voltage diagnostics and substitute-value output.

At a Glance

Brand Siemens
Model 6ES7132-6GD51-0BA0
Product Type Signal relay output module
Core Function Galvanically isolated signal switching
Application ET 200SP BaseUnit type A0

Four isolated changeover contacts

Each relay channel provides a changeover contact for low-voltage signal circuits with up to 2 A per channel.

Defined fault response

Configurable substitute values define the requested output behavior when the station applies a substitute state.

Supply and module diagnostics

The PWR and DIAG indicators support supply and module checks, while channel LEDs show output status.

Product Overview

6ES7132-6GD51-0BA0 switches low-voltage signals through four isolated changeover contacts in an ET 200SP station.

The module provides supply-voltage monitoring, channel status indication and configurable substitute values; the permitted combined output current depends on mounting orientation and ambient temperature.

Ordering focus: Match BaseUnit type A0, the 24 V signal-switching limit and the temperature-dependent total relay current.
Key Functions

Four isolated changeover contacts

Each relay channel provides a changeover contact for low-voltage signal circuits with up to 2 A per channel.

Defined fault response

Configurable substitute values define the requested output behavior when the station applies a substitute state.

Supply and module diagnostics

The PWR and DIAG indicators support supply and module checks, while channel LEDs show output status.

Official Specifications
Relay arrangement 4 isolated changeover contacts
Contact switching voltage 24 V AC or 24 V DC, rated
Maximum channel current 2 A
Minimum switching load 1 mA at 5 V DC
Maximum switching frequency 2 Hz with resistive load
Combined current, horizontal 8 A up to 40 °C; 6 A up to 50 °C; 4 A up to 60 °C
Combined current, vertical 8 A up to 30 °C; 6 A up to 40 °C; 4 A up to 50 °C
Module supply 24 V DC; permitted 19.2–28.8 V DC
Rated module consumption 50 mA
Typical power loss 1.2 W
Relay endurance Maximum 500,000 operating cycles
Output short-circuit protection Not integrated
Maximum cable lengths 1,000 m shielded; 200 m unshielded
Address space 1 output byte; an additional input byte for QI information
Isolation test 707 V DC, type test
Operating temperature −30 to +60 °C horizontal; −30 to +50 °C vertical
Module width 15 mm
Height and depth 73 × 58 mm
Approximate weight 30 g
Frequently Asked Questions

Can 6ES7132-6GD51-0BA0 switch a 230 V AC signal?

The rated contact-switching voltage is 24 V AC or 24 V DC.

Which BaseUnit do I need beneath 6ES7132-6GD51-0BA0?

Use an ET 200SP BaseUnit of type A0 with the CC00 color-code arrangement.

Can I switch 2 A on all channels of 6ES7132-6GD51-0BA0 at 60 degrees Celsius?

At 60 °C in horizontal installation, the module’s total output current is limited to 4 A.

Can I parallel the outputs of 6ES7132-6GD51-0BA0 to increase current capacity?

Parallel outputs are not permitted for current uprating.

Does 6ES7132-6GD51-0BA0 detect a short circuit or broken load wire?

The module provides supply-voltage diagnostics but no short-circuit or wire-break diagnostics.

What PLC address space is needed for 6ES7132-6GD51-0BA0?

The module uses one output byte and an additional input byte when QI information is used.

Can I assign 6ES7132-6GD51-0BA0 to a safety shutdown function?

The module is not suitable for safety functions.

Compatibility & Ordering Notes
Before ordering 6ES7132-6GD51-0BA0: Match BaseUnit type A0, the 24 V signal-switching limit and the temperature-dependent total relay current.

Before installation

  • Use BaseUnit type A0 and the CC00 identification arrangement.
  • Keep switched signals within the 24 V AC/DC contact rating.
  • Apply the total-current limit for the selected orientation and cabinet temperature.
  • Provide external output protection and do not parallel channels to increase current capacity.
Hot Selling Models
5714AAL
3RV2011-1JA25
DNC-32-80-PPV-A-S2
VP342-5DZ1-02A
342583 M12
TS500-00-2R-5
F117x1 07400015
SZ4139.140
CXSM10-10
VSVA-B-P53ED-ZD-A2-1T1L-SA SA-244020A B720
T3C 235-11z-M20
NJ20 + E2
VABV-S4-1HS-G14-2T2
NBC-MSD/10.0-93G/R4AC
PLC-BSC-120UC/21

Get a Free Quote

Our representative will contact you soon.
Email
Name
Company Name
Message
0/1000
email goToTop

Evolo Automation is not an authorized distributor unless otherwise specified, representative, or affiliate of the manufacturer of this product. All trademarks and documents are the property of their respective owners and are provided for identification and informational.