siemens 6es7132 6bf00 0ca0 et 200sp dq 8x24vdc 0 5a hf output module-0

For SIEMENS

Home >  Products >  For SIEMENS

Siemens 6ES7132-6BF00-0CA0 ET 200SP DQ 8x24VDC/0.5A HF Output Module

Manufacturer: Siemens
Condition: Brand New
Lead Time: In Stock
Origin: Germany
Warranty: 12 Months

  • Overview
  • Hot Selling Models
  • Recommended Products
Overview
SIEMENS SIMATIC ET 200SP

6ES7132-6BF00-0CA0 ET 200SP DQ 8x24VDC/0.5A HF Output Module

Eight PNP source outputs with 0.5 A per channel, 4 A module capacity and channel-level wire-break and short-circuit diagnostics.

At a Glance

Brand Siemens
Model 6ES7132-6BF00-0CA0
Product Type High Feature digital output module
Core Function Switching field loads with channel fault reporting
Application A0 BaseUnits in ET 200SP stations

Eight source outputs

Each channel switches up to 0.5 A from the 24 V load supply.

Individual diagnostics

Red channel LEDs distinguish channel faults from ordinary output states.

Flexible data ownership

MSO mode and quality information support subdivided output assignments.

Product Overview

6ES7132-6BF00-0CA0 switches eight 24 V DC loads using PNP current-sourcing outputs. The High Feature module combines individual output parameters with channel-level short-circuit and wire-break diagnostics, supply monitoring and selectable substitute values.

The A0 module uses the CC02 color assignment and occupies a 15 mm station position. Its maximum address allocation depends on the submodule and quality-information arrangement, while its total output current remains limited to 4 A.

Ordering focus: Match the A0 BaseUnit and CC02 assignment, then check output loading, channel diagnostics and the selected data layout.
Key Functions

Drive DC actuators

Eight PNP source outputs provide a rated 0.5 A per channel and up to 4 A for the module.

Locate channel faults

Wire-break and short-circuit diagnostics operate channel by channel, with red channel LEDs and module DIAG indication.

Integrate timed and shared output data

The module supports isochronous operation, MSO and quality information for the configured submodules.

Official Specifications
Output channels 8 PNP current-sourcing outputs
Load supply 24 V DC rated; permissible range 19.2–28.8 V; reverse-polarity protection
Rated current consumption 28 mA
Typical power loss 1 W
Output loading 0.5 A per channel; 4 A per module up to 60 °C horizontally or 50 °C vertically
Maximum off-state residual current 0.1 mA
Typical resistive-load delay 50 µs on; 100 µs off
Short-circuit response threshold Typically 0.7–1.3 A
Inductive shutdown-voltage limit Typically L+ minus 50 V
Load resistance 48 Ω to 12 kΩ
Maximum lamp load 5 W
Maximum switching rates Resistive: 100 Hz; inductive: 2 Hz; lamps: 10 Hz
Maximum field-cable length 1,000 m shielded; 600 m unshielded
Maximum address allocation 8 bytes with two channels per submodule and quality information
Isochronous timing Minimum TCO 48 µs; minimum TDP 500 µs
Diagnostic indicators Green PWR and channel state; red channel fault; green/red DIAG
Isolation Channels isolated from backplane, not from each other; 707 V DC type test
Operating temperature Horizontal: −30 to +60 °C; vertical: −30 to +50 °C; below 0 °C from FS07
Dimensions and approximate weight 15 × 73 × 58 mm (W × H × D); 30 g
Frequently Asked Questions

Can I parallel outputs of 6ES7132-6BF00-0CA0 to supply a higher load current?

Parallel output switching is not permitted for increasing the current rating.

How can I identify an individual wiring fault on 6ES7132-6BF00-0CA0?

The module provides channel-level wire-break and short-circuit diagnostics with a red fault LED for the affected channel.

Does 6ES7132-6BF00-0CA0 support a current-sinking actuator circuit?

The outputs are PNP current-sourcing outputs and do not provide current sinking.

How fast can 6ES7132-6BF00-0CA0 repeatedly switch an inductive load?

The maximum inductive-load switching rate is 2 Hz.

What BaseUnit arrangement is needed for a three-wire load on 6ES7132-6BF00-0CA0?

Use an A0 BaseUnit with AUX terminals or an A0 base with a potential distributor module.

Can 6ES7132-6BF00-0CA0 continue with selected output values during a fault condition?

Substitute values can be enabled for the configured outputs.

Which engineering versions can configure 6ES7132-6BF00-0CA0?

The module is configurable with TIA Portal V13 SP1, STEP 7 V5.5 or PCS 7 V8.1 SP1 and later supported versions.

Compatibility & Ordering Notes
Before ordering 6ES7132-6BF00-0CA0: Select the A0 BaseUnit and CC02 terminal identification, then match the wiring variant, diagnostic needs and output data layout.

Compatibility Checklist for 6ES7132-6BF00-0CA0

  • Use an A0 base with the AUX or potential-distributor arrangement required by the load wiring.
  • Limit each channel to 0.5 A and the module to 4 A.
  • Do not parallel outputs to increase current rating.
  • Select the intended submodule, quality-information and substitute-value configuration in the engineering project.
Hot Selling Models
AR60F10
6ES7590-1AJ30-0AA0
258-30-33
OBD300-12GM40-E5-V1
85071 MCS10-3x400-500/24
6ES5377-0AA21
3VU1600-1MN00
R64G-NNK-RMN
3VF1231-1FC41-0AB4
WS-C2950SX-24
DN32 PN10
6ES5740-0AA11
5.08/17 SN OR 1709520000
8143455
3RM1302-1AA04

Get a Free Quote

Our representative will contact you soon.
Email
Name
Company Name
Message
0/1000
email goToTop

Evolo Automation is not an authorized distributor unless otherwise specified, representative, or affiliate of the manufacturer of this product. All trademarks and documents are the property of their respective owners and are provided for identification and informational.