siemens 6es5482 4ua20 simatic s5 di dq 482 digital i o module-0

For SIEMENS

Home >  Products >  For SIEMENS

Siemens 6ES5482-4UA20 SIMATIC S5 DI/DQ 482 Digital I/O Module

Manufacturer: Siemens
Condition: Brand New
Lead Time: In Stock
Origin: Germany
Warranty: 12 Months

  • Overview
  • Hot Selling Models
  • Recommended Products
Overview
SIEMENS SIMATIC S5

6ES5482-4UA20 SIMATIC S5 DI/DQ 482 Digital I/O Module

DI/DQ 482 combines fixed and configurable 24 V DC channels, providing 16 to 24 inputs and 8 to 16 outputs within a 32-channel isolated group.

At a Glance

Brand Siemens
Model 6ES5482-4UA20
Product Type Configurable digital I/O module
Core Function Discrete process-signal exchange
Application S5-135U, S5-155U and EU 185U systems

Configurable middle byte

Eight channels can be assigned individually as inputs or outputs.

24 V DC signals

The output switching range is 5 mA to 0.5 A.

S5 system integration

The 4UA20 version operates without the IP 257 interface.

Product Overview

6ES5482-4UA20 is a SIMATIC S5 DI/DQ 482 module with 16 fixed inputs, eight fixed outputs and eight individually configurable channels. All 32 channels share one isolated group rather than separate input and output potential groups.

The user program determines how the configurable byte is used, allowing the channel allocation to follow the installed process wiring within the supported input and output totals.

Ordering focus: Match the channel assignment, common potential group and S5 rack configuration, and retain the distinction between the 4UA20 and the IP 257-capable 4UA11 version.
Key Functions

Flexible channel allocation

Channels 0.0 to 0.7 are fixed outputs, channels 2.0 to 3.7 are fixed inputs, and channels 1.0 to 1.7 can each operate as an input or output.

Process output switching

The 24 V DC outputs switch resistive and inductive loads within the individual-channel and eight-output group limits.

Program-controlled use

Input access and output assignment determine use of the configurable channels, while an input-designated channel must retain a zero in its output register bit.

Official Specifications
Input capacity 16 fixed inputs plus up to 8 configurable inputs
Output capacity 8 fixed outputs plus up to 8 configurable outputs
Rated field supply 24 V DC
Input thresholds Logic 0: −33 to +7 V; logic 1: 13 to 33 V
Typical input current 7 mA
Input delay Typically 0.3 ms; range 0.15 to 0.5 ms
Typical input resistance 3.3 kΩ
Maximum unshielded input line 50 m
Output switching current 5 mA to 0.5 A
Output-group total current Maximum 4 A per 8 outputs
Maximum resistive switching frequency 100 Hz
Maximum inductive switching frequency 2 Hz at 0.3 A; 0.5 Hz at 0.5 A
Output fuse 7 A fast-acting; one fuse per 8 outputs
Maximum unshielded output line 400 m
Typical backplane consumption 80 mA at 5 V
Typical field-supply consumption 220 mA at 24 V
Nominal power loss 8 W
Isolation arrangement One common group for all 32 inputs and outputs
Dimensions (W × H × D) 20 × 255 × 195 mm
Approximate weight 0.4 kg
Frequently Asked Questions

Can I use 6ES5482-4UA20 with an IP 257 interface?

The 4UA20 version does not provide the IP 257 interface.

Which channels can I change between input and output on 6ES5482-4UA20?

The eight channels addressed as 1.0 to 1.7 can each be assigned as an input or an output.

Are the input and output groups of 6ES5482-4UA20 isolated separately?

All 32 input and output channels form one common isolated group.

What must I do with the output bit when a configurable channel on 6ES5482-4UA20 is an input?

The corresponding output register bit must remain zero when that channel is used as an input.

Can I connect different sensor and 1L+ supplies to 6ES5482-4UA20?

When any configurable channel is used as an input, its sensors and the 1L+ connection must use the same power supply.

How much current can eight outputs of 6ES5482-4UA20 carry together?

An eight-output group has a maximum total switching current of 4 A, subject to the ventilation and temperature conditions.

Can 6ES5482-4UA20 switch a 0.5 A inductive load twice per second?

At 0.5 A the maximum inductive switching frequency is 0.5 Hz, while 2 Hz applies at 0.3 A.

Compatibility & Ordering Notes
Before ordering 6ES5482-4UA20: Preserve the installed fixed and configurable byte assignments, the shared potential group and the output fusing arrangement when replacing an existing DI/DQ 482.

Compatibility Checklist for 6ES5482-4UA20

  • Use the module in a supported S5-135U, S5-155U or EU 185U system.
  • Keep unused channels unwired and unaddressed.
  • Supply configurable input sensors and 1L+ from the same source.
  • Respect 4 A per eight outputs and the ventilation-dependent total-load limit.
Hot Selling Models
EGT005194
OJ5063 OJP-FPKG/FO/0.15M/US
3110022
CONDSUB4490°PVC03
VKP-1035R250
CPE14-M1BH-3GLS-QS-6
D040009DWG
DNCB-32-50-PPV-A
12T-0.5-RSM 50/S1587/S3254 UX01211
3RV2011-0DA25
VUVG-L14-T32U-AT-G18-1P3
LV-21AP
CPE14M1BH3GLQS6
M22DRLY
GLV12-6/36/40b/115

Get a Free Quote

Our representative will contact you soon.
Email
Name
Company Name
Message
0/1000
email goToTop

Evolo Automation is not an authorized distributor unless otherwise specified, representative, or affiliate of the manufacturer of this product. All trademarks and documents are the property of their respective owners and are provided for identification and informational.