6ES5451-7LA11 SIMATIC S5 32-Channel Digital Output Module

32 optocoupled 24 V DC outputs in groups of eight, with 0.5 A rated channel current and electronic short-circuit protection.

At a Glance

Brand Siemens
Model 6ES5451-7LA11
Product Type Floating digital output module
Core Function Switching of DC field loads
Application SIMATIC S5-115H I/O systems

Four isolated output groups

The 32 outputs are optocoupled in groups of eight for separate field-potential organization.

Electronic load protection

Electronic short-circuit protection and inductive switch-off voltage limiting support direct connection of suitable DC loads.

Long field wiring reach

Output wiring can extend to 1000 m with shielding or 600 m without shielding within the specified installation conditions.

Product Overview

6ES5451-7LA11 switches 32 DC output circuits in a SIMATIC S5 installation, using optocouplers to isolate the field output groups.

Four groups of eight outputs provide 0.5 A per channel at a nominal 24 V DC load supply, with electronic short-circuit protection and defined switching limits for resistive and inductive loads.

Ordering focus: Match the S5 rack and front-connector wiring to the 32-channel grouped output arrangement, and apply the aggregate-current derating at elevated temperature.
Key Functions

Four isolated output groups

The 32 outputs are optocoupled in groups of eight for separate field-potential organization.

Electronic load protection

Electronic short-circuit protection and inductive switch-off voltage limiting support direct connection of suitable DC loads.

Long field wiring reach

Output wiring can extend to 1000 m with shielding or 600 m without shielding within the specified installation conditions.

Official Specifications
Output count and grouping 32 digital outputs in groups of 8
Output isolation Optocoupler isolation
Load supply voltage 24 V DC nominal; 20–30 V permissible
Permitted supply surge 35 V for 0.5 s
Minimum signal-high voltage L+ minus 2.5 V
Rated channel current 0.5 A
Maximum lamp load 5 W
Signal-low leakage current 1 mA maximum
Parallel output connection Not permitted
Aggregate output-current derating 100% at 25°C; 50% at 55°C
Short-circuit protection Electronic
Inductive switch-off voltage limit −15 V
Maximum switching frequency 100 Hz resistive; 0.5 Hz inductive
Maximum output cable length 1000 m shielded; 600 m unshielded
Intergroup insulation 30 V DC rated; 500 V AC test
Internal 5 V current consumption 100 mA
No-load L+ current 17 mA per group
Typical module power loss 20 W
Approximate mass 0.7 kg
Frequently Asked Questions

How are the outputs of 6ES5451-7LA11 separated into potential groups?

The 32 optocoupled outputs are arranged in four groups of eight.

Can I parallel two channels of 6ES5451-7LA11 for a larger load?

Parallel connection of outputs is not permitted.

How much current can one channel of 6ES5451-7LA11 switch?

Each channel is rated for 0.5 A with a maximum lamp load of 5 W.

Must I reduce the total loading of 6ES5451-7LA11 at 55°C?

The permissible sum of output currents is reduced to 50% at 55°C compared with 100% at 25°C.

How fast can 6ES5451-7LA11 switch inductive loads?

Inductive switching is limited to 0.5 Hz, while resistive switching can reach 100 Hz.

What is the wiring-distance limit for 6ES5451-7LA11?

Output cable length is limited to 1000 m when shielded or 600 m when unshielded.

Does 6ES5451-7LA11 provide short-circuit protection for its outputs?

The output circuits have electronic short-circuit protection.

Compatibility & Ordering Notes
Before ordering 6ES5451-7LA11: Match the S5 rack and front-connector wiring to the 32-channel grouped output arrangement, and apply the aggregate-current derating at elevated temperature.

Before installation

  • Use the S5-115H front-connector assignment for the four groups of eight output circuits.
  • Keep the load supply within 20–30 V DC during normal operation.
  • Do not parallel output channels to increase load current.
  • Apply the total-current temperature derating and the 5 W lamp-load limit when allocating field loads.
Hot Selling Models
Allen-Bradley 1734-IJ
859-801
12M06 PSK-IBSL 200299
1739630000
120-001-02
DNC-40-50-PPV
Allen-Bradley 1734-IB8
506308
M08MG1-NSC60F-S04G
LB66PC7K
1734IB8 PN-130651
Allen-Bradley 1734-OB8E
33-11ZG-ST
G3K-TSSL
WT100-P1432S02 6033003

Get a Free Quote

Our representative will contact you soon.
Email
Name
Company Name
Message
0/1000
email goToTop

Evolo Automation is not an authorized distributor unless otherwise specified, representative, or affiliate of the manufacturer of this product. All trademarks and documents are the property of their respective owners and are provided for identification and informational.