Overview
SITOP PSU6200

6EP3321-7SB00-0AX0 SITOP PSU6200 12 V 2 A Power Supply

A narrow 12 V, 2 A supply with AC/DC input, push-in terminals and 24 W nominal output.

At a Glance

Brand Siemens
Model 6EP3321-7SB00-0AX0
Product Type Stabilized DC power supply
Core Function Providing regulated low-voltage power
Application DIN-rail control-panel supplies

Wide-range AC/DC input

The supply accommodates a single-phase AC source or a DC source within its specified input ranges.

Adjustable regulated output

A potentiometer adjusts the output from 10.5 to 12.9 V.

Narrow push-in construction

The compact rail housing uses push-in power terminals and permits adjacent housings to be lined up.

Product Overview

6EP3321-7SB00-0AX0 provides a regulated 12 V supply for control-panel loads.

The 25 mm-wide PSU6200 accepts single-phase AC or DC input and combines an adjustable output with periodic-restart short-circuit protection.

Ordering focus: Match the AC/DC source, 24 W load budget, protective-earth connection and rail clearances.
Key Functions

Wide-range AC/DC input

The supply accommodates a single-phase AC source or a DC source within its specified input ranges.

Adjustable regulated output

A potentiometer adjusts the output from 10.5 to 12.9 V.

Narrow push-in construction

The compact rail housing uses push-in power terminals and permits adjacent housings to be lined up.

Official Specifications
Permitted AC input 85–264 V AC; 47–63 Hz; nominal 120–240 V
Permitted DC input 110–275 V DC; nominal 120–240 V
Rated output 12 V DC, 2 A; 24 W
Output adjustment 10.5–12.9 V via potentiometer
Maximum input current by nominal voltage 0.45 A at 120 V; 0.25 A at 240 V
Maximum inrush current 32 A at 25 °C
Mains buffering At least 150 ms at 240 V input and rated output current
Maximum residual ripple 30 mV; 20 mV typical
Static regulation 0.3% for slow input-voltage changes and slow resistive-load changes
Startup behavior Maximum delay 1 s; typical output rise time 50 ms
Efficiency and typical loaded loss 83.3%; 5 W at rated output
Maximum no-load loss 0.8 W
Short-circuit response Electronic shutdown with periodic restart attempts; typical limiting current 2.8 A
Electrical protection Class I; isolated SELV output; IP20
Operating ambient −25 to +70 °C with natural convection
Transport and storage ambient −40 to +85 °C
Power terminals Push-in connections for 0.5–2.5 mm² conductors
Mounting and clearance 35 mm DIN rail; 50 mm above and below, 0 mm at sides
Dimensions and net mass 25 × 100 × 88 mm (W × H × D); 0.2 kg
Frequently Asked Questions

How long can 6EP3321-7SB00-0AX0 buffer a mains interruption at rated load?

At 240 V input and rated output current, the specified minimum buffering time is 150 ms.

Can 6EP3321-7SB00-0AX0 operate from a 270 V DC source?

The permitted DC input range extends from 110 to 275 V.

Can I parallel 6EP3321-7SB00-0AX0 with another unit to increase power?

Parallel operation for increasing output power is not supported.

How much free space is needed above and below 6EP3321-7SB00-0AX0?

Leave 50 mm clearance above and below the supply.

Does 6EP3321-7SB00-0AX0 need a protective-earth connection?

The Class I input arrangement includes a protective-earth connection.

Can 6EP3321-7SB00-0AX0 continue to power a shorted load indefinitely?

Short-circuit protection shuts the output down and makes periodic restart attempts.

What load-power limit applies when I adjust 6EP3321-7SB00-0AX0 toward 12.9 V?

The adjusted output must remain within the maximum 24 W power limit.

Compatibility & Ordering Notes
Before ordering 6EP3321-7SB00-0AX0: Match the AC/DC source, 24 W load budget, protective-earth connection and rail clearances.

Before installation

  • Keep the load within both the output-current and 24 W power limits.
  • Use the correct input polarity and protective-earth connection for the selected supply source.
  • Provide 50 mm clearance above and below for natural convection.
  • Select feeder protection and terminal conductors for the installation.
Hot Selling Models
A3T2.5VLBL 2428850000
ABL8 RPS24050
M11 031281
2.53036398
Telemecanique XAP M11 031281
2.5303639
FXON-65EC
7000-08061-6310100
VUVG-PS3E-T-M7-1P3 VAVE-L1-1VR8-LP
OP-87360 RJ45
XS1M18MA230G
MFS201
KF2000/1 RT.4-06 50027784
7000-14061-8400750
KP-10-350

Get a Free Quote

Our representative will contact you soon.
Email
Name
Company Name
Message
0/1000
email goToTop

Evolo Automation is not an authorized distributor unless otherwise specified, representative, or affiliate of the manufacturer of this product. All trademarks and documents are the property of their respective owners and are provided for identification and informational.