Siemens 6EP1961-3BA21 SITOP PSE202U 24 V DC 40 A Redundancy Module
Manufacturer: Siemens
Condition: Brand New
Lead Time: In Stock
Origin: Germany
Warranty: 12 Months
Email: [email protected]
whatsApp: +86-18150117685
- Overview
- Hot Selling Models
- Recommended Products
Overview
- Operate from the specified 24–28.8 V DC input range.
- Allow approximately 0.5 V of voltage drop through the redundancy path.
- Keep the load within the surviving power supply capacity for redundancy.
- Set the monitoring threshold between 20 and 25 V for the application.
- Maintain SELV/ES1 conditions for the relay-contact circuit.
- Use an insulated screwdriver when adjusting the potentiometer.
- Observe high-temperature derating above +60 °C and provide 50 mm upper and lower clearances.
6EP1961-3BA21 SITOP PSE202U 24 V DC 40 A Redundancy Module
A 24 V DC decoupling module for two power supplies rated up to 20 A each, with a 40 A aggregate output path and adjustable input-voltage monitoring.
At a Glance
| Brand | Siemens |
|---|---|
| Model | 6EP1961-3BA21 |
| Product Type | Redundancy module |
| Core Function | Decouples two DC power supplies |
| Application | Redundant 24 V DC industrial power systems |
Two decoupled inputs
The module combines two SITOP power supplies with a maximum of 20 A per supply.
Adjustable voltage monitoring
The signal threshold can be set between 20 and 25 V.
Remote status contact
An isolated changeover relay reports whether both input voltages exceed the set threshold.
Product Overview
6EP1961-3BA21 decouples two SITOP DC power supplies and feeds their common load through a redundancy output path.
The module handles up to 40 A of aggregate output current from supplies rated up to 20 A each, with approximately 0.5 V of voltage drop; the available load after a supply failure remains limited by the surviving supply.
Key Functions
Decouple the two supply outputs
The redundancy path isolates the two connected supply outputs from each other while feeding a common DC load.
Monitor both input voltages
A green indication and an OK relay condition require both input voltages to exceed the adjustable threshold, while a red indication identifies an input below it.
Provide potential-free status signaling
The isolated changeover contact makes the supply-status signal available to an external monitoring circuit.
Official Specifications
| DC input voltage range | 24–28.8 V |
|---|---|
| Maximum connected supply current | 20 A per power supply |
| Aggregate output current | 40 A maximum |
| Output voltage relationship | Input voltage minus approximately 0.5 V |
| Input-voltage monitoring threshold | Adjustable from 20 to 25 V |
| Signaling contact rating | Isolated changeover contact, 8 A at 240 V AC or 24 V DC |
| Efficiency | 96.6% |
| Power dissipation | 34 W typical at rated load; 1.5 W maximum at no load |
| Input-to-output galvanic isolation | None |
| Enclosure protection | IP20 |
| Operating temperature | −25 to +60 °C with natural convection |
| High-temperature derating | 3% per kelvin from +60 to +70 °C |
| Storage and transport temperature | −40 to +85 °C |
| Relative humidity | 5–95%, non-condensing; climatic class 3K3 |
| Power and ground terminals | Screw terminals for 0.33–10 mm² solid or finely stranded conductors |
| Relay-contact terminals | Three screw terminals for 0.5–2.5 mm² solid or finely stranded conductors |
| Enclosure dimensions (W × H × D) | 70 × 125 × 120 mm |
| Net weight | 0.5 kg |
| Mounting rail | EN 60715, 35 × 7.5 mm or 35 × 15 mm |
| Installation clearances | 50 mm above and below; 0 mm on either side |
Frequently Asked Questions
Can two 20 A supplies provide a fully redundant 40 A load through 6EP1961-3BA21?
The redundant load must stay within the capacity of one surviving supply even though the module output path permits 40 A in aggregate.
How much voltage drop should be allowed across 6EP1961-3BA21?
The output voltage is approximately 0.5 V below the input voltage.
What does a red indicator on 6EP1961-3BA21 mean?
At least one input voltage is below the selected monitoring threshold.
Can the input-voltage alarm point of 6EP1961-3BA21 be adjusted?
The threshold can be set from 20 to 25 V.
Does 6EP1961-3BA21 electrically isolate the power output from the inputs?
There is no galvanic isolation between the power inputs and the output.
How much ventilation space is needed above and below 6EP1961-3BA21?
Provide 50 mm clearance above and below the module for the specified installation.
Which contact can be used to monitor 6EP1961-3BA21 remotely?
The isolated changeover relay provides an OK signal when both inputs exceed the selected threshold and is rated at 8 A for 240 V AC or 24 V DC.