Get a Free Quote

Our representative will contact you soon.
Email
Name
Company Name
Message
0/1000
siemens 6ep1334 2aa01 sitop smart 24 v 10 a power supply-0

For SIEMENS

Home >  Products >  For SIEMENS

Siemens 6EP1334-2AA01 SITOP smart 24 V 10 A Power Supply

Manufacturer: Siemens
Condition: Brand New
Lead Time: In Stock
Origin: Germany
Warranty: 12 Months

  • Overview
  • Hot Selling Models
  • Recommended Products
Overview
SITOP smart

6EP1334-2AA01 SITOP smart 24 V 10 A Power Supply

SITOP smart 240 W supply with switch-selected 120/230 V AC input, a ten-ampere rated output and an adjustable 22.8–28 V output setting.

At a Glance

Brand Siemens
Model 6EP1334-2AA01
Product Type Stabilized control power supply
Core Function Isolated AC-to-DC power conversion
Application Higher-current industrial 24 V loads

Higher-current control supply

The rated output delivers twenty-four volts at ten amperes to the connected control circuit.

Short-duration overload reserve

The supply provides separate startup and in-service overload-current intervals.

Cabinet power integration

Screw terminals, a narrow DIN-rail housing and stated thermal loss support cabinet integration.

Product Overview

6EP1334-2AA01 supplies isolated, stabilized twenty-four-volt DC power for higher-current control circuits.

The DIN-rail unit combines output-current reserve with defined overload, ripple and recovery behavior for cabinet power-system design.

Ordering focus: Match the ten-ampere load, mains selection, startup-current allowance and DIN-rail ventilation space.
Key Functions

Higher-current control supply

The rated output delivers twenty-four volts at ten amperes to the connected control circuit.

Short-duration overload reserve

The supply provides separate startup and in-service overload-current intervals.

Cabinet power integration

Screw terminals, a narrow DIN-rail housing and stated thermal loss support cabinet integration.

Official Specifications
Mains input ranges Switch-selected 120/230 V AC; 85–132 V or 170–264 V
Input frequency 47–63 Hz; nominal 50/60 Hz
Rated input current 4.1 A at 120 V; 2.4 A at 230 V
Maximum inrush and duration 65 A at 25°C; typical duration 3 ms; maximum I²t 3.3 A²s
Rated output 24 V DC; 10 A; 240 W
Voltage adjustment 22.8–28 V
Available output-current range 0–12 A; 12 A up to +45°C
Minimum mains buffering 20 ms at rated load with input 93/187 V
Ripple and voltage spikes Ripple: 50 mV typical, 150 mV maximum; spikes: 150 mV typical, 240 mV maximum
Overload during startup 30 A typical for 100 ms
Overload during operation 33 A typical for 200 ms
Current limiting and sustained short circuit Current-limit response 12.5–13.5 A; typical sustained short-circuit RMS current 16 A
Overvoltage threshold Below 33 V
Efficiency and power loss 90%; typical loss 27 W at rated output
Load-step settling 0.2 ms typical for both 50-to-100% and 100-to-50% resistive load steps
Operating and storage ambient Operation 0 to +60°C with natural convection; storage/transport −40 to +85°C
Enclosure and safety class IP20; Class I; isolated SELV output
Screw-terminal conductors 0.5–2.5 mm²; L, N and PE one each, L+ and M two each
Required free space 50 mm above and below; 0 mm at left and right
Dimensions and mounting 70 × 125 × 125 mm (W × H × D); EN 60715 35 × 7.5/15 mm DIN rail
Frequently Asked Questions

What switch-on current must the feeder of 6EP1334-2AA01 accommodate?

The maximum inrush current is sixty-five amperes at twenty-five degrees Celsius with a typical duration of three milliseconds.

Will 6EP1334-2AA01 shut off immediately rather than limit current during a short circuit?

The supply uses a constant-current characteristic, with a current-limit response of 12.5–13.5 A and a typical sustained short-circuit RMS current of 16 A.

Can I install 6EP1334-2AA01 with no vertical ventilation gap?

Provide fifty millimetres of free space both above and below the housing.

How are the input and output terminals arranged on 6EP1334-2AA01?

The supply has one screw terminal each for L, N and PE and two each for L+ and M, accepting conductors from 0.5 to 2.5 square millimetres.

Can I screw 6EP1334-2AA01 directly to a wall without a mounting accessory?

This version is specified for the stated thirty-five-millimetre DIN rail and does not support direct wall mounting.

Does 6EP1334-2AA01 provide an NEC Class 2 output?

The supply is not classified as an NEC Class 2 source.

What thermal loss should I include for 6EP1334-2AA01 at rated output?

The typical power loss at rated output is twenty-seven watts.

Compatibility & Ordering Notes
Before ordering 6EP1334-2AA01: Match the ten-ampere load, mains selection, startup-current allowance and DIN-rail ventilation space.

Before installation

  • Match the mains selector position to the incoming voltage and allow the specified inrush current in the feeder design.
  • Keep the normal load within the ten-ampere rating and apply the forty-five-degree limit to a twelve-ampere load.
  • Provide DIN-rail mounting with fifty-millimetre upper and lower clearances.
  • Use the specified terminal conductors and account for the output protection characteristic when coordinating downstream circuits.
Hot Selling Models
1416431/M12MS/IP20/LI/3
ZSB-1.5/8-S/+/-/PE
RT1N
UKN35BU 3034099
20/24 85394
1754970000
SRB-NA-RC.16-24V
VS102
DW-AD-713-M18-245
3RT1966-4G E:02
EC206
01358000A
SL10.100
RT1H 113705
170681

Get a Free Quote

Our representative will contact you soon.
Email
Name
Company Name
Message
0/1000
email goToTop