Siemens 6EP1333-2BA01 SITOP smart 24 V 5 A PFC Power Supply
Manufacturer: Siemens
Condition: Brand New
Lead Time: In Stock
Origin: Germany
Warranty: 12 Months
Email: [email protected]
whatsApp: +86-18150117685
- Overview
- Hot Selling Models
- Recommended Products
Overview
- Set the 120/230 V selector to match the incoming supply before applying power.
- Size the five-ampere load and any six-ampere operating requirement for the actual cabinet temperature.
- Provide the specified feeder protection and retain fifty millimetres of free space above and below the housing.
- Mount on the specified DIN rail and account for isolated Class I wiring and the load’s startup-voltage tolerance.
6EP1333-2BA01 SITOP smart 24 V 5 A PFC Power Supply
SITOP smart 120 W supply with selectable 120/230 V AC input, an adjustable 24 V DC output and a five-ampere rated output.
At a Glance
| Brand | Siemens |
|---|---|
| Model | 6EP1333-2BA01 |
| Product Type | Stabilized DC power supply |
| Core Function | Single-phase AC conversion with power-factor correction |
| Application | Industrial 24 V control circuits |
PFC input conversion
The PFC input version supplies a stabilized twenty-four-volt control circuit from the selected AC mains range.
Adjustable output reserve
Output adjustment and a six-ampere operating range up to forty-five degrees Celsius support the connected load.
Load-fault response
Constant-current protection and a short overload interval define the supply response to load faults.
Product Overview
6EP1333-2BA01 provides an isolated, stabilized DC supply for industrial control loads from a selected single-phase AC input range.
The PFC version combines voltage adjustment, short-duration overload capability and constant-current short-circuit behavior in a fifty-millimetre-wide DIN-rail housing.
Key Functions
PFC input conversion
The PFC input version supplies a stabilized twenty-four-volt control circuit from the selected AC mains range.
Adjustable output reserve
Output adjustment and a six-ampere operating range up to forty-five degrees Celsius support the connected load.
Load-fault response
Constant-current protection and a short overload interval define the supply response to load faults.
Official Specifications
| Input network and selection | Single-phase 120/230 V AC, selected by device switch; 85–132 V or 170–264 V; 47–63 Hz |
|---|---|
| Rated input current | 2.1 A at 120 V; 1.15 A at 230 V |
| Inrush characteristic | Maximum 32 A at 25°C; typical duration 3 ms; maximum I²t 0.8 A²s |
| Rated DC output | 24 V; 5 A; 120 W |
| Output voltage adjustment | 22.8–28 V by potentiometer |
| Extended output-current range | 0–6 A; 6 A up to +45°C |
| Mains buffering | Minimum 20 ms at rated load and input 93/187 V |
| Output ripple and spikes | Ripple: 50 mV typical, 150 mV maximum; spikes: 150 mV typical, 240 mV maximum |
| Startup response | Maximum delay 0.1 s; typical voltage rise 50 ms; approximately 4% overshoot |
| Short overload capability | 17 A typical; 100 ms during startup or 200 ms during operation |
| Current-limit response | 6.4–6.6 A; constant-current short-circuit characteristic |
| Overvoltage protection | Output below 33 V |
| Efficiency and typical loss | 87%; 17 W at rated output |
| Internal fuse | T 3.15 A / 250 V; not accessible |
| Operating ambient | 0 to +60°C with natural convection |
| Storage and transport ambient | −40 to +85°C |
| Protection and insulation | IP20; Class I; isolated SELV output |
| Terminal conductors | 0.5–2.5 mm²; one terminal each for L, N and PE, two each for L+ and M |
| Mounting and ventilation | EN 60715 35 × 7.5/15 mm DIN rail; 50 mm clearance above and below |
| Dimensions and net weight | 50 × 125 × 125 mm (W × H × D); 0.5 kg |
Frequently Asked Questions
Will 6EP1333-2BA01 automatically select any mains voltage between 85 and 264 V?
The device requires the correct selector-switch position for either the 85–132 V or the 170–264 V input range.
Can 6EP1333-2BA01 supply six amperes continuously in a cool cabinet?
The output range extends to six amperes at ambient temperatures up to forty-five degrees Celsius.
Can I connect two units of 6EP1333-2BA01 in parallel to increase available power?
The supply supports parallel operation of two units for increasing output power.
Can I replace the internal fuse of 6EP1333-2BA01 through an accessible fuse holder?
The internal T 3.15 A fuse is not accessible.
What startup voltage excursion should I allow for loads supplied by 6EP1333-2BA01?
The output voltage can overshoot its set value by approximately four percent during switch-on.
How long can 6EP1333-2BA01 bridge a mains interruption at rated load?
The minimum buffering time is twenty milliseconds at an input of 93 or 187 V.
Which external feeder characteristic is recommended for 6EP1333-2BA01?
The feeder recommendation is a miniature circuit breaker with characteristic C and a rating starting from six amperes.