Overview
LOGO! 0BA6

6ED1052-2MD00-0BA6 LOGO! 12/24RCO Logic Module

Display-free LOGO! 12/24RCO with 200 function blocks, eight digital inputs including four analog-capable channels, four relay outputs and time-switch functions.

At a Glance

Brand Siemens
Model 6ED1052-2MD00-0BA6
Product Type Expandable logic module without display
Core Function Compact logic with digital/analog inputs and relay outputs
Application Small automation systems using 12/24 V DC control power

Mixed input capability

Eight digital inputs are available, and four of them can alternatively be used for 0–10 V analog signals.

Relay load switching

Four relay outputs switch the application loads within the specified resistive or inductive current limits.

Time-based compact automation

The module provides 200 function blocks, eight time-switch clocks and an 80-hour clock reserve.

Product Overview

6ED1052-2MD00-0BA6 is a modular LOGO! 12/24RCO logic module without an integrated display. It operates from a 12 or 24 V DC supply and combines eight digital inputs with four relay outputs in a compact DIN-rail housing.

Four of the inputs can be used in 0–10 V analog mode, allowing mixed signal requirements to be handled by the base module. The 200-block memory, eight time-switch clocks and modular expansion capability support compact control applications with time-dependent logic.

Ordering focus: Select the display-free RCO version, check shared digital/analog input use and verify output contact ratings and external fusing for each load.
Key Functions

Mixed input capability

Eight digital inputs are available, and four of them can alternatively be used for 0–10 V analog signals.

Relay load switching

Four relay outputs switch the application loads within the specified resistive or inductive current limits.

Time-based compact automation

The module provides 200 function blocks, eight time-switch clocks and an 80-hour clock reserve.

Official Specifications
Nominal supply 12 / 24 V DC
Permissible supply range 10.8–28.8 V DC
Digital inputs 8; four can be used in 0–10 V analog mode
Digital outputs 4 relay outputs
Maximum relay contact current 10 A resistive load; 3 A inductive load
Output short-circuit protection Not integrated; external fusing is required
Program memory 200 function blocks
Time-switch clocks 8
Clock power reserve 80 hours
Expansion Modular expandable
Display Without display
Mounting 35 mm DIN rail; 4 spacing units wide
Degree of protection IP20
Operating temperature 0 to +55 °C
Dimensions (W × H × D) 72 × 90 × 55 mm
Frequently Asked Questions

Does 6ED1052-2MD00-0BA6 include a built-in display?

No; the 12/24RCO version is supplied without an integrated display.

Are the analog inputs of 6ED1052-2MD00-0BA6 additional to its eight digital inputs?

No; four of the eight inputs can alternatively be used in analog mode for 0–10 V signals.

How much function-block memory does 6ED1052-2MD00-0BA6 provide?

The specified program memory holds 200 function blocks.

How long is the clock reserve of 6ED1052-2MD00-0BA6?

The time-switch clocks have an 80-hour power reserve.

Can an inductive load on 6ED1052-2MD00-0BA6 be sized using the 10 A contact limit?

No; 10 A applies to resistive loads, while the specified inductive-load limit is 3 A.

Does 6ED1052-2MD00-0BA6 protect its relay outputs against short circuits?

No; external fusing is necessary.

Can 6ED1052-2MD00-0BA6 be expanded beyond the base-module I/O?

Yes; the base module has a modular expandable design.

Compatibility & Ordering Notes
Before ordering 6ED1052-2MD00-0BA6: Select the display-free RCO version, check shared digital/analog input use and verify output contact ratings and external fusing for each load.

Before installation

  • Confirm that the application requires the 12/24 V DC RCO version without display.
  • Document which shared inputs are configured for digital signals and which use 0–10 V analog mode.
  • Choose external output protection and size the contacts for the actual inductive or resistive load.
  • Allow the four-unit DIN-rail width and check the complete expansion arrangement before wiring.
Hot Selling Models
W4P2EZ0-G1
MK33-LI-Ex0
13283592
SL-VS01
B07-2BH-A3KG
DFE32B 18213456
3RV2411-1FA20
SACB-8/16-LC
6FC9320-3GS
84G-6GK-RFN
6BB2C2668700000
170INT11001 + 170ADM35010
0854156
SLT-20-20-PA
CL400 A24V/0.5A-ESF

Get a Free Quote

Our representative will contact you soon.
Email
Name
Company Name
Message
0/1000
email goToTop

Evolo Automation is not an authorized distributor unless otherwise specified, representative, or affiliate of the manufacturer of this product. All trademarks and documents are the property of their respective owners and are provided for identification and informational.