Get a Free Quote

Our representative will contact you soon.
Email
Name
Company Name
Message
0/1000
siemens 6dl1165 6tf00 0ph1 et 200pa smart aq 8xi hart analog output module-0

For SIEMENS

Home >  Products >  For SIEMENS

Siemens ET 200PA SMART+ AQ 8xI HART Analog Output Module 6DL1165-6TF00-0PH1

Manufacturer: Siemens
Condition: Brand New
Lead Time: In Stock
Origin: Germany
Warranty: 12 Months

  • Overview
  • Product Overview
  • Key Functions
  • Official Specifications
  • Frequently Asked Questions
  • Compatibility & Ordering Notes
  • Hot Selling Models
  • Recommended Products
Overview

Siemens • SIMATIC ET 200PA SMART+

6DL1165-6TF00-0PH1 ET 200PA SMART+ AQ 8xI HART Analog Output Module

The AQ 8xI HART PA module provides eight configurable current outputs for process actuators, with HART communication, substitute values, channel diagnostics and long shielded cable support.

At a Glance

Brand Siemens
Model 6DL1165-6TF00-0PH1
Product Type Eight-channel HART analog output module
Core Function Controls process actuators and exchanges smart-device data
Application or Compatible Series ET 200PA SMART+ process I/O

Exact Identification

Match 6DL1165-6TF00-0PH1 character by character and confirm the complete ET 200PA SMART+ AQ 8xI HART Analog Output Module designation.

Interface Arrangement

Confirm the installed supply, ports, field connections and required accessories before wiring the replacement.

Configuration Check

Preserve the approved engineering project, network parameters and application data used by the installed system.

Product Overview

The AQ 8xI HART PA module provides eight configurable current outputs for process actuators, with HART communication, substitute values, channel diagnostics and long shielded cable support.

Channels support unipolar, bipolar and live-zero current output ranges. HART-capable outputs allow supported device communication through the process-I/O station. Supply monitoring, wire-break, short-circuit and overrange or underrange diagnostics support maintenance.

Ordering focus: confirm the complete AQ8 HART article number, station release, channel ranges, actuator loads, HART assignments, terminal wiring, substitute values and diagnostics.
Key Functions

Flexible Current Ranges

Channels support unipolar, bipolar and live-zero current output ranges.

HART Field Communication

HART-capable outputs allow supported device communication through the process-I/O station.

Channel Diagnostics

Supply monitoring, wire-break, short-circuit and overrange or underrange diagnostics support maintenance.

Official Specifications
Supported Current Ranges 0 to 10 mA, 0 to 20 mA, -20 to +20 mA and 4 to 20 mA
Resolution 15 bit or 16 bit including sign, depending on range
Actuator Connection Two-wire current output
Maximum Resistive Load 750 Ω
Maximum Inductive Load 10 mH
Externally Applied Output Voltage Limit -0.3 to +36 V
Maximum Shielded Cable Length 1000 m
Resistive-Load Settling Time 1.2 ms at 750 Ω
Inductive-Load Settling Time 0.5 ms
Linearity Error ±0.01 % of output range
Temperature Error ±0.001 %/K of output range
Minimum Output Crosstalk Attenuation 70 dB
Repeat Accuracy at 25 °C ±0.02 % of output range
Operational Current Error ±0.5 % across the full temperature range
Basic Current Error at 25 °C ±0.1 %
Substitute Values Configurable
Channel Status Indication Green LED
Maintenance Indication Yellow MAINT LED
Frequently Asked Questions

Which current ranges can I configure on 6DL1165-6TF00-0PH1?

Select the supported unipolar, bipolar or 4 to 20 mA range required by each actuator.

Can 6DL1165-6TF00-0PH1 communicate with HART field devices?

Yes; configure HART communication and the corresponding channel parameters in the control-system project.

What output load can 6DL1165-6TF00-0PH1 drive?

Keep a resistive current-output load within 750 Ω and an inductive load within 10 mH.

How far can the shielded output cable run from 6DL1165-6TF00-0PH1?

A shielded output cable may be up to 1000 m under the documented installation conditions.

Which faults can 6DL1165-6TF00-0PH1 diagnose per channel?

The module can report wire-break, short-circuit, range and supply-related diagnostic conditions as configured.

What should I preserve before changing 6DL1165-6TF00-0PH1?

Save every output range, substitute value, HART assignment, diagnostic enable and field-terminal record.

How should I commission replacement outputs on 6DL1165-6TF00-0PH1?

Verify wiring and load first, then test scaling, safe substitute values, HART communication and each actuator response.

Compatibility & Ordering Notes
Before ordering 6DL1165-6TF00-0PH1: confirm the complete AQ8 HART article number, station release, channel ranges, actuator loads, HART assignments, terminal wiring, substitute values and diagnostics.

Compatibility Checklist

  • Use only output loads and cable lengths within the documented limits.
  • Match each HART device and current range to the configured channel.
  • Validate substitute values and safe process response before enabling outputs.
Hot Selling Models
SAL-12-TS5.1-TK5.1/A0223
7000-89501-2400200
EC48P275/1A
7000-74301-7960020
FLKM-D15 SUB/B/FFKDS/SO485
KTO011 01140.0-00
REX2000
ZK1020-0101-0030
SAC-4P-M12MSD/1.0-930/M12MSD
LZS:PT3A5L24
LWL7R32BHS2
ZB4BA6
LTRk-E12
ZCKD21 064672
R060201210