Accipe Aestimationem Gratuitam

Legatus noster te mox contactabit.
Epistula electronica
Nomen
Nomen societatis
Nuntius
0/1000

Siemens ET 200PA SMART+ AQ 8xI HART Analog Output Module 6DL1165-6TF00-0PH1

Fabricator: Siemens
Condición: Nuevo
Plazo de Entrega: En Stock
Origo: Germania
Garantía: 12 Meses

Inscriptio electronica: [email protected]

whatsapp: +86-18150117685

  • Conspectus
  • Product Overview
  • Key Functions
  • Official Specifications
  • Quaestiones Frequenter Rogatae
  • Compatibility & Ordering Notes
  • Hot Selling Models
  • Producta commendata
Conspectus

Siemens • SIMATIC ET 200PA SMART+

6DL1165-6TF00-0PH1 ET 200PA SMART+ AQ 8xI HART Analog Output Module

The AQ 8xI HART PA module provides eight configurable current outputs for process actuators, with HART communication, substitute values, channel diagnostics and long shielded cable support.

Ad Primum Aspectum

Nota Siemens
Modellum 6DL1165-6TF00-0PH1
Typus Producti Eight-channel HART analog output module
Functio principalis Controls process actuators and exchanges smart-device data
Applicatio vel series compatibiles ET 200PA SMART+ process I/O

Identificatio exacta.

Match 6DL1165-6TF00-0PH1 character by character and confirm the complete ET 200PA SMART+ AQ 8xI HART Analog Output Module designation.

Arrangementum Interfacis

Confirmare ante connexionem substitutionis supplitum installatum, portus, connexiones campestres et accessoria requisa.

Configuration Check

Servare projectum ingenieriae approbatum, parametres rete et data applicationis quae systema installatum utitur.

Product Overview

The AQ 8xI HART PA module provides eight configurable current outputs for process actuators, with HART communication, substitute values, channel diagnostics and long shielded cable support.

Channels support unipolar, bipolar and live-zero current output ranges. HART-capable outputs allow supported device communication through the process-I/O station. Supply monitoring, wire-break, short-circuit and overrange or underrange diagnostics support maintenance.

Focus ordinandi: confirmare numerum articuli AQ8 HART completum, liberationem stationis, intervalla canalium, onera actuatorum, attributiones HART, connexiones terminalium, valores substituti et diagnosia.
Key Functions

Intervalla Currentis Flexibilia

Canalia supportant intervalla currentis unipolaria, bipolaria et cum zero vivo.

Communicatio HART in Campo

Emissiones capaces HART permittunt communicationem cum dispositivis supportatis per stationem processus-I/O.

Diagnostics Canalium

Supervisio suppetiarum, interruptio fili, circuitus curtus et diagnosia super-vel sub-intervallorum ad auxilium manutentionis.

Official Specifications
Ambitus currentis supportati 0 ad 10 mA, 0 ad 20 mA, -20 ad +20 mA et 4 ad 20 mA
Resolutio 15 bit vel 16 bit, incluse signum, secundum intervallum
Coniunctio Actuatoris Emissio currentis bi-filari
Maxima Impedantia Resistiva 750 Ω
Maximum Inductivum Onus 10 mH
Limitis Tensionis Externae Applicatae -0,3 usque ad +36 V
Maxima Longitudo Cavi Scutati 1000 m
Tempus Stabilizationis Onus Resistivum 1,2 ms ad 750 Ω
Tempus Stabilizationis Onus Inductivum 0,5 ms
Error Linearitatis ±0,01 % intervali output
Error Temperaturae ±0,001 %/K intervali output
Minima Attenutatio Crosstalk Output 70 dB
Accuratio Repetitionis ad 25 °C ±0,02 % intervali output
Error Currentis Operationalis ±0.5 % per totum intervallum temperaturarum
Basic Current Error at 25 °C ±0,1 %
Valores substituti Configurabilis
Indicatio status canalium LED viridis
Indicatio maintenance Flava LED MAINT
Quaestiones Frequenter Rogatae

Quae intervalla currentis configurare possum in 6DL1165-6TF00-0PH1?

Elige intervallum unipolare, bipolare aut 4 ad 20 mA quod singulae actuatores postulant.

Num 6DL1165-6TF00-0PH1 cum dispositivis HART communicare potest?

Ita; configura communicationem HART et parametra canalium correspondientia in projecto systematis de controllo.

Quam magnam onus outputi 6DL1165-6TF00-0PH1 movet?

Mantene onus currentis outputi resistivum infra 750 Ω et onus inductivum infra 10 mH.

Quousque catena outputi cincta a 6DL1165-6TF00-0PH1 progredi potest?

Catena outputi cincta usque ad 1000 m sub condicionibus installationis documentatis esse potest.

Quae vitia 6DL1165-6TF00-0PH1 per canallem diagnosticare potest?

Modulus conditiones diagnosticas rupturae fili, cortocircuitus, ambitus et supply-relatas, ut configuratus est, referre potest.

Quid servare debes antequam 6DL1165-6TF00-0PH1 mutas?

Serva omnem ambitum outputi, valorem substitutum, attributionem HART, activationem diagnosticam et recordum terminalis campi.

Quomodo outputs substitutionis in 6DL1165-6TF00-0PH1 committendas curas?

Primum verificare connexiones et onus, deinde probare scalationem, valores substitutos securitatis, communicationem HART et responsionem uniuscuiusque actuatoris.

Compatibility & Ordering Notes
Ante ordinandum 6DL1165-6TF00-0PH1: confirmare numerum articuli AQ8 HART completum, liberationem stationis, intervalla canalium, onera actuatorum, attributiones HART, connexiones terminalium, valores substituti et diagnosia.

Index Compatibilitatis

  • Utere tantum oneribus exsurgentibus et longitudinibus caviis intra limites documentatos.
  • Adaequa unumquemque dispositivum HART et intervallum currentis ad canalem configuratum.
  • Verifica valores substitutos et responsum processus tutum antequam activaveris exsultus.
Hot Selling Models
SAL-12-TS5.1-TK5.1/A0223
7000-89501-2400200
EC48P275/1A
7000-74301-7960020
FLKM-D15 SUB/B/FFKDS/SO485
KTO011 01140.0-00
REX2000
ZK1020-0101-0030
SAC-4P-M12MSD/1.0-930/M12MSD
LZS:PT3A5L24
LWL7R32BHS2
ZB4BA6
LTRk-E12
ZCKD21 064672
R060201210

Accipe Aestimationem Gratuitam

Legatus noster te mox contactabit.
Epistula electronica
Nomen
Nomen societatis
Nuntius
0/1000
epistula electronica ad Summum ire

Evolo Automation non est distributor autorizatus nisi aliter specificatum, nec representans, nec affinis fabricantis huius producti. Omnia signa propria et documenta sunt proprietatis suorum dominorum respective et data sunt ad identificationem et informationem.