Siemens SIMATIC ET 200SP HA F-DI 16x24VDC HA Module 6DL1136-6BA00-0PH1
Manufacturer: Siemens
Condition: Brand New
Lead Time: In Stock
Origin: Germany
Warranty: 12 Months
Email: [email protected]
whatsApp: +86-18150117685
- Overview
- Product Overview
- Key Functions
- Official Specifications
- Frequently Asked Questions
- Compatibility & Ordering Notes
- Hot Selling Models
- Recommended Products
Overview
Siemens • SIMATIC ET 200SP HA
6DL1136-6BA00-0PH1 SIMATIC ET 200SP HA F-DI 16x24VDC HA Module
The SIMATIC ET 200SP HA F-DI 16x24VDC HA module acquires sixteen fail-safe 24 V DC inputs and supports SIL 3 and PL e safety applications with channel-level diagnostics.
At a Glance
| Brand | Siemens |
|---|---|
| Model | 6DL1136-6BA00-0PH1 |
| Product Type | Fail-safe 16-channel digital input module |
| Core Function | Acquires 24 V DC safety-related digital signals with channel diagnostics |
| Application or Compatible Series | Safety Instrumented Functions in SIMATIC ET 200SP HA process automation systems |
Exact Identification
Match 6DL1136-6BA00-0PH1 character by character and confirm the complete SIMATIC ET 200SP HA F-DI 16x24VDC HA Module designation.
Interface Arrangement
Confirm the installed supply, ports, field connections and required accessories before wiring the replacement.
Configuration Check
Preserve the approved engineering project, network parameters and application data used by the installed system.
Product Overview
The SIMATIC ET 200SP HA F-DI 16x24VDC HA module acquires sixteen fail-safe 24 V DC inputs and supports SIL 3 and PL e safety applications with channel-level diagnostics.
Sixteen channels acquire safety-related 24 V DC field signals in the HA station. The module supports applications up to SIL 3 and Performance Level e when integrated as specified. Wire-break and short-circuit diagnostics support fault localization during commissioning and maintenance.
Key Functions
Sixteen Fail-Safe Inputs
Sixteen channels acquire safety-related 24 V DC field signals in the HA station.
High Safety Capability
The module supports applications up to SIL 3 and Performance Level e when integrated as specified.
Channel Diagnostics
Wire-break and short-circuit diagnostics support fault localization during commissioning and maintenance.
Official Specifications
| Input Channels | 16 |
|---|---|
| Input Characteristic | IEC 61131 Type 1 |
| Signal Evaluation | P-reading |
| Rated Supply Voltage | 24 V DC |
| Permissible Supply Range | 19.2 to 28.8 V DC |
| Reverse-Polarity Protection | Provided |
| Rated Current Consumption | 80 mA |
| Maximum Current Consumption | 150 mA |
| Sensor-Supply Outputs | 16 |
| Maximum Current per Sensor Supply | 0.5 A |
| Maximum Current per Module | 8 A |
| Backplane-Bus Power | 90 mW |
| Typical Power Loss | 3.2 W |
| Input Signal 0 | -30 to +5 V |
| Input Signal 1 | +15 to +30 V |
| Pulse Extension | 50 ms, 100 ms, 200 ms, 500 ms, 1 s or 2 s |
| Timestamp Resolution | 10 ms |
| Safety Capability | Up to SIL 3 / PL e |
| Terminal Block Types | H1, M1, H0 or N0 |
| Configuration Control | CC01 |
Frequently Asked Questions
How many safety inputs are provided by 6DL1136-6BA00-0PH1?
The module provides sixteen fail-safe 24 V DC digital input channels.
Which terminal blocks can be used with 6DL1136-6BA00-0PH1?
Use the approved H1, M1, H0 or N0 terminal-block arrangement required by the station design.
Can 6DL1136-6BA00-0PH1 be used in a SIL 3 function?
Yes; the complete safety loop must be engineered, validated and proof-tested for the required SIL.
Which field faults can 6DL1136-6BA00-0PH1 diagnose?
Configured channel diagnostics include wire break and short circuit to M.
How should sensor-supply loading be checked for 6DL1136-6BA00-0PH1?
Verify each output stays within 0.5 A and the total module load stays within 8 A.
What project data must match when replacing 6DL1136-6BA00-0PH1?
Match the terminal block, channel parameters, safety signature, firmware and validated F-system configuration.
What should be tested after installing 6DL1136-6BA00-0PH1?
Perform channel diagnostics, discrepancy and shutdown tests, verify timestamps and complete the approved safety validation.
Compatibility & Ordering Notes
Compatibility Checklist
- Use only with the approved ET 200SP HA terminal-block configuration.
- Revalidate the complete SIL or PL safety function after replacement.
- Match firmware and fail-safe project parameters before commissioning.