Get a Free Quote

Our representative will contact you soon.
Email
Name
Company Name
Message
0/1000
siemens 6dl1136 6ba00 0ph1 simatic et 200sp ha f di 16x24vdc ha module-0

For SIEMENS

Home >  Products >  For SIEMENS

Siemens SIMATIC ET 200SP HA F-DI 16x24VDC HA Module 6DL1136-6BA00-0PH1

Manufacturer: Siemens
Condition: Brand New
Lead Time: In Stock
Origin: Germany
Warranty: 12 Months

  • Overview
  • Product Overview
  • Key Functions
  • Official Specifications
  • Frequently Asked Questions
  • Compatibility & Ordering Notes
  • Hot Selling Models
  • Recommended Products
Overview

Siemens • SIMATIC ET 200SP HA

6DL1136-6BA00-0PH1 SIMATIC ET 200SP HA F-DI 16x24VDC HA Module

The SIMATIC ET 200SP HA F-DI 16x24VDC HA module acquires sixteen fail-safe 24 V DC inputs and supports SIL 3 and PL e safety applications with channel-level diagnostics.

At a Glance

Brand Siemens
Model 6DL1136-6BA00-0PH1
Product Type Fail-safe 16-channel digital input module
Core Function Acquires 24 V DC safety-related digital signals with channel diagnostics
Application or Compatible Series Safety Instrumented Functions in SIMATIC ET 200SP HA process automation systems

Exact Identification

Match 6DL1136-6BA00-0PH1 character by character and confirm the complete SIMATIC ET 200SP HA F-DI 16x24VDC HA Module designation.

Interface Arrangement

Confirm the installed supply, ports, field connections and required accessories before wiring the replacement.

Configuration Check

Preserve the approved engineering project, network parameters and application data used by the installed system.

Product Overview

The SIMATIC ET 200SP HA F-DI 16x24VDC HA module acquires sixteen fail-safe 24 V DC inputs and supports SIL 3 and PL e safety applications with channel-level diagnostics.

Sixteen channels acquire safety-related 24 V DC field signals in the HA station. The module supports applications up to SIL 3 and Performance Level e when integrated as specified. Wire-break and short-circuit diagnostics support fault localization during commissioning and maintenance.

Ordering focus: confirm the exact F-DI article number, terminal-block type, firmware, sixteen-channel wiring, safety parameters, sensor-supply loading, diagnostics and validated F-system signature.
Key Functions

Sixteen Fail-Safe Inputs

Sixteen channels acquire safety-related 24 V DC field signals in the HA station.

High Safety Capability

The module supports applications up to SIL 3 and Performance Level e when integrated as specified.

Channel Diagnostics

Wire-break and short-circuit diagnostics support fault localization during commissioning and maintenance.

Official Specifications
Input Channels 16
Input Characteristic IEC 61131 Type 1
Signal Evaluation P-reading
Rated Supply Voltage 24 V DC
Permissible Supply Range 19.2 to 28.8 V DC
Reverse-Polarity Protection Provided
Rated Current Consumption 80 mA
Maximum Current Consumption 150 mA
Sensor-Supply Outputs 16
Maximum Current per Sensor Supply 0.5 A
Maximum Current per Module 8 A
Backplane-Bus Power 90 mW
Typical Power Loss 3.2 W
Input Signal 0 -30 to +5 V
Input Signal 1 +15 to +30 V
Pulse Extension 50 ms, 100 ms, 200 ms, 500 ms, 1 s or 2 s
Timestamp Resolution 10 ms
Safety Capability Up to SIL 3 / PL e
Terminal Block Types H1, M1, H0 or N0
Configuration Control CC01
Frequently Asked Questions

How many safety inputs are provided by 6DL1136-6BA00-0PH1?

The module provides sixteen fail-safe 24 V DC digital input channels.

Which terminal blocks can be used with 6DL1136-6BA00-0PH1?

Use the approved H1, M1, H0 or N0 terminal-block arrangement required by the station design.

Can 6DL1136-6BA00-0PH1 be used in a SIL 3 function?

Yes; the complete safety loop must be engineered, validated and proof-tested for the required SIL.

Which field faults can 6DL1136-6BA00-0PH1 diagnose?

Configured channel diagnostics include wire break and short circuit to M.

How should sensor-supply loading be checked for 6DL1136-6BA00-0PH1?

Verify each output stays within 0.5 A and the total module load stays within 8 A.

What project data must match when replacing 6DL1136-6BA00-0PH1?

Match the terminal block, channel parameters, safety signature, firmware and validated F-system configuration.

What should be tested after installing 6DL1136-6BA00-0PH1?

Perform channel diagnostics, discrepancy and shutdown tests, verify timestamps and complete the approved safety validation.

Compatibility & Ordering Notes
Before ordering 6DL1136-6BA00-0PH1: confirm the exact F-DI article number, terminal-block type, firmware, sixteen-channel wiring, safety parameters, sensor-supply loading, diagnostics and validated F-system signature.

Compatibility Checklist

  • Use only with the approved ET 200SP HA terminal-block configuration.
  • Revalidate the complete SIL or PL safety function after replacement.
  • Match firmware and fail-safe project parameters before commissioning.
Hot Selling Models
5SL6216-6
ZS-39-5G
efector100 N7S20A I7S2002-N/1G/1D
ABB E211X-16-10
3SB3244-6AA50
ABB E214-16-101
ABB E215-16-11D
6ES7131-6BF01-0BA0
Allen-Bradley 100-FA11
VMPA-AP 533375
3SB3202-0AA51
E66085-H
7000-88001-6500100
7000-88005-6200100
ZB5AS834 090691

Get a Free Quote

Our representative will contact you soon.
Email
Name
Company Name
Message
0/1000
email goToTop

Evolo Automation is not an authorized distributor unless otherwise specified, representative, or affiliate of the manufacturer of this product. All trademarks and documents are the property of their respective owners and are provided for identification and informational.