Conspectus
Siemens • SIMATIC ET 200SP HA
6DL1136-6BA00-0PH1 SIMATIC ET 200SP HA F-DI 16x24VDC HA Module
Modulus SIMATIC ET 200SP HA F-DI 16x24VDC HA accepit sedecim intratus digitales fail-safe 24 V DC et sustinet applicationes securitatis SIL 3 et PL e cum diagnosticis per canalum.
Ad Primum Aspectum
| Nota | Siemens |
|---|---|
| Modellum | 6DL1136-6BA00-0PH1 |
| Typus Producti | Modulus digitalis intrantium fail-safe 16 canalium |
| Functio principalis | Accepit signa digitalia 24 V DC ad securitatem pertinentia cum diagnosticis per canalum |
| Applicatio vel series compatibiles | Functiones Instrumentatae Securitatis in systematibus automationis processus SIMATIC ET 200SP HA |
Identificatio exacta.
Compare character by character the designation 6DL1136-6BA00-0PH1 and confirm the full SIMATIC ET 200SP HA F-DI 16x24VDC HA Module designation.
Arrangementum Interfacis
Confirmare ante connexionem substitutionis supplitum installatum, portus, connexiones campestres et accessoria requisa.
Configuration Check
Servare projectum ingenieriae approbatum, parametres rete et data applicationis quae systema installatum utitur.
Product Overview
Modulus SIMATIC ET 200SP HA F-DI 16x24VDC HA accepit sedecim intratus digitales fail-safe 24 V DC et sustinet applicationes securitatis SIL 3 et PL e cum diagnosticis per canalum.
Sixteen channels acquire safety-related 24 V DC field signals in the HA station. The module supports applications up to SIL 3 and Performance Level e when integrated as specified. Wire-break and short-circuit diagnostics support fault localization during commissioning and maintenance.
Key Functions
Sixteen Fail-Safe Inputs
Sixteen channels acquire safety-related 24 V DC field signals in the HA station.
High Safety Capability
The module supports applications up to SIL 3 and Performance Level e when integrated as specified.
Diagnostics Canalium
Wire-break and short-circuit diagnostics support fault localization during commissioning and maintenance.
Official Specifications
| Canali Ingressus | 16 |
|---|---|
| Caracteristica input | Typus IEC 61131-1 |
| Signal Evaluation | P-reading |
| Tensio nominalis supplicii | 24 V DC |
| AMPLITUDO ADMISSIBILIS FONDIS | 19,2 ad 28,8 V CC |
| Protectio contra polaritatem inversam | Praebitum |
| Consumptio Currentis Nominalis | 80 mA |
| Maxima Consumptio Electrica | 150 mA |
| Sensor-Supply Outputs | 16 |
| Maximalis Currus per Sensorium Alimentationem | 0,5 A |
| Maximum Current per Module | 8 A |
| Potentia dorsi-bus | 90 mW |
| Perditio potentiæ typica | 3.2 W |
| Input signal 0 | −30 ad +5 V |
| Signum introductum 1 | +15 ad +30 V |
| Extensio impulsum | 50 ms, 100 ms, 200 ms, 500 ms, 1 s aut 2 s |
| Resolutio Temporis | 10 ms |
| Capacitas Securitatis | Usque ad SIL 3 / PL e |
| Typus Blockus Terminalis | H1, M1, H0 aut N0 |
| Controlus configurationis | CC01 |
Quaestiones Frequenter Rogatae
Quot introitus tutelares 6DL1136-6BA00-0PH1 praebet?
Modulus sedecim canales introitus digitalis 24 V DC fallendi tutos praebet.
Quae blocos terminalium cum 6DL1136-6BA00-0PH1 uti possunt?
Utare ordinem blocorum terminalium approbatum H1, M1, H0 aut N0 quem designatio stationis requirit.
Num 6DL1136-6BA00-0PH1 in functione SIL 3 uti potest?
Yes; the complete safety loop must be engineered, validated and proof-tested for the required SIL.
Which field faults can 6DL1136-6BA00-0PH1 diagnose?
Configured channel diagnostics include wire break and short circuit to M.
How should sensor-supply loading be checked for 6DL1136-6BA00-0PH1?
Verify each output stays within 0.5 A and the total module load stays within 8 A.
What project data must match when replacing 6DL1136-6BA00-0PH1?
Match the terminal block, channel parameters, safety signature, firmware and validated F-system configuration.
What should be tested after installing 6DL1136-6BA00-0PH1?
Perform channel diagnostics, discrepancy and shutdown tests, verify timestamps and complete the approved safety validation.
Compatibility & Ordering Notes
Index Compatibilitatis
- Utere tantum cum configuratione approbata terminalis ET 200SP HA.
- Revalida functionem integram SIL vel PL post substitutionem.
- Consona parametris firmware et projecti fail-safe antequam in operationem mittatur.