Accipe Aestimationem Gratuitam

Legatus noster te mox contactabit.
Epistula electronica
Nomen
Nomen societatis
Nuntius
0/1000

Siemens SIMATIC ET 200SP HA F-DI 16x24VDC HA Module 6DL1136-6BA00-0PH1

Fabricator: Siemens
Condición: Nuevo
Plazo de Entrega: En Stock
Origo: Germania
Garantía: 12 Meses

Inscriptio electronica: [email protected]

whatsapp: +86-18150117685

  • Conspectus
  • Product Overview
  • Key Functions
  • Official Specifications
  • Quaestiones Frequenter Rogatae
  • Compatibility & Ordering Notes
  • Hot Selling Models
  • Producta commendata
Conspectus

Siemens • SIMATIC ET 200SP HA

6DL1136-6BA00-0PH1 SIMATIC ET 200SP HA F-DI 16x24VDC HA Module

Modulus SIMATIC ET 200SP HA F-DI 16x24VDC HA accepit sedecim intratus digitales fail-safe 24 V DC et sustinet applicationes securitatis SIL 3 et PL e cum diagnosticis per canalum.

Ad Primum Aspectum

Nota Siemens
Modellum 6DL1136-6BA00-0PH1
Typus Producti Modulus digitalis intrantium fail-safe 16 canalium
Functio principalis Accepit signa digitalia 24 V DC ad securitatem pertinentia cum diagnosticis per canalum
Applicatio vel series compatibiles Functiones Instrumentatae Securitatis in systematibus automationis processus SIMATIC ET 200SP HA

Identificatio exacta.

Compare character by character the designation 6DL1136-6BA00-0PH1 and confirm the full SIMATIC ET 200SP HA F-DI 16x24VDC HA Module designation.

Arrangementum Interfacis

Confirmare ante connexionem substitutionis supplitum installatum, portus, connexiones campestres et accessoria requisa.

Configuration Check

Servare projectum ingenieriae approbatum, parametres rete et data applicationis quae systema installatum utitur.

Product Overview

Modulus SIMATIC ET 200SP HA F-DI 16x24VDC HA accepit sedecim intratus digitales fail-safe 24 V DC et sustinet applicationes securitatis SIL 3 et PL e cum diagnosticis per canalum.

Sixteen channels acquire safety-related 24 V DC field signals in the HA station. The module supports applications up to SIL 3 and Performance Level e when integrated as specified. Wire-break and short-circuit diagnostics support fault localization during commissioning and maintenance.

Focus ordinandi: confirm the exact F-DI article number, terminal-block type, firmware, sixteen-channel wiring, safety parameters, sensor-supply loading, diagnostics, and validated F-system signature.
Key Functions

Sixteen Fail-Safe Inputs

Sixteen channels acquire safety-related 24 V DC field signals in the HA station.

High Safety Capability

The module supports applications up to SIL 3 and Performance Level e when integrated as specified.

Diagnostics Canalium

Wire-break and short-circuit diagnostics support fault localization during commissioning and maintenance.

Official Specifications
Canali Ingressus 16
Caracteristica input Typus IEC 61131-1
Signal Evaluation P-reading
Tensio nominalis supplicii 24 V DC
AMPLITUDO ADMISSIBILIS FONDIS 19,2 ad 28,8 V CC
Protectio contra polaritatem inversam Praebitum
Consumptio Currentis Nominalis 80 mA
Maxima Consumptio Electrica 150 mA
Sensor-Supply Outputs 16
Maximalis Currus per Sensorium Alimentationem 0,5 A
Maximum Current per Module 8 A
Potentia dorsi-bus 90 mW
Perditio potentiæ typica 3.2 W
Input signal 0 −30 ad +5 V
Signum introductum 1 +15 ad +30 V
Extensio impulsum 50 ms, 100 ms, 200 ms, 500 ms, 1 s aut 2 s
Resolutio Temporis 10 ms
Capacitas Securitatis Usque ad SIL 3 / PL e
Typus Blockus Terminalis H1, M1, H0 aut N0
Controlus configurationis CC01
Quaestiones Frequenter Rogatae

Quot introitus tutelares 6DL1136-6BA00-0PH1 praebet?

Modulus sedecim canales introitus digitalis 24 V DC fallendi tutos praebet.

Quae blocos terminalium cum 6DL1136-6BA00-0PH1 uti possunt?

Utare ordinem blocorum terminalium approbatum H1, M1, H0 aut N0 quem designatio stationis requirit.

Num 6DL1136-6BA00-0PH1 in functione SIL 3 uti potest?

Yes; the complete safety loop must be engineered, validated and proof-tested for the required SIL.

Which field faults can 6DL1136-6BA00-0PH1 diagnose?

Configured channel diagnostics include wire break and short circuit to M.

How should sensor-supply loading be checked for 6DL1136-6BA00-0PH1?

Verify each output stays within 0.5 A and the total module load stays within 8 A.

What project data must match when replacing 6DL1136-6BA00-0PH1?

Match the terminal block, channel parameters, safety signature, firmware and validated F-system configuration.

What should be tested after installing 6DL1136-6BA00-0PH1?

Perform channel diagnostics, discrepancy and shutdown tests, verify timestamps and complete the approved safety validation.

Compatibility & Ordering Notes
Before ordering 6DL1136-6BA00-0PH1: confirm the exact F-DI article number, terminal-block type, firmware, sixteen-channel wiring, safety parameters, sensor-supply loading, diagnostics, and validated F-system signature.

Index Compatibilitatis

  • Utere tantum cum configuratione approbata terminalis ET 200SP HA.
  • Revalida functionem integram SIL vel PL post substitutionem.
  • Consona parametris firmware et projecti fail-safe antequam in operationem mittatur.
Hot Selling Models
5SL6216-6
ZS-39-5G
efector100 N7S20A I7S2002-N/1G/1D
ABB E211X-16-10
3SB3244-6AA50
ABB E214-16-101
ABB E215-16-11D
6ES7131-6BF01-0BA0
Allen-Bradley 100-FA11
VMPA-AP 533375
3SB3202-0AA51
E66085-H
7000-88001-6500100
7000-88005-6200100
ZB5AS834 090691

Accipe Aestimationem Gratuitam

Legatus noster te mox contactabit.
Epistula electronica
Nomen
Nomen societatis
Nuntius
0/1000
epistula electronica ad Summum ire

Evolo Automation non est distributor autorizatus nisi aliter specificatum, nec representans, nec affinis fabricantis huius producti. Omnia signa propria et documenta sunt proprietatis suorum dominorum respective et data sunt ad identificationem et informationem.