Overview
SIPLUS S7-200

6AG1223-1PL22-2XB0 SIPLUS S7-200 EM 223 16DI 16 Relay Output Module

SIPLUS EM 223 with sixteen 24 V DC inputs and sixteen 2 A relay outputs for an extended environmental range.

At a Glance

Brand Siemens
Model 6AG1223-1PL22-2XB0
Product Type Digital input and relay output module
Core Function Extended-temperature discrete machine I/O
Application S7-22X CPU expansion systems

Combined input and relay expansion

Sixteen 24 V DC inputs and sixteen relay outputs extend the controller field connections.

Grouped load switching

Relay outputs are isolated in groups of four and permit up to 8 A per group.

Extended SIPLUS environment

The catalog specifies extended temperature operation and permissible condensation.

Product Overview

6AG1223-1PL22-2XB0 adds sixteen digital inputs and sixteen relay outputs to an S7-22X CPU expansion system.

The SIPLUS design supports an extended −25 to +70°C ambient range and condensation, while its relay circuits provide grouped isolation for switching field loads.

Ordering focus: Match the S7-22X station, relay load voltage, 2 A channel and 8 A group limits, and required SIPLUS environment.
Key Functions

Combined input and relay expansion

Sixteen 24 V DC inputs and sixteen relay outputs extend the controller field connections.

Grouped load switching

Relay outputs are isolated in groups of four and permit up to 8 A per group.

Extended SIPLUS environment

The catalog specifies extended temperature operation and permissible condensation.

Official Specifications
Channel arrangement 16 digital inputs; 16 relay outputs
Input voltage 24 V DC; signal 0: 0–5 V; signal 1: 15–30 V
Typical input current 4 mA at signal 1
Maximum rising input delay 4.5 ms
DC load-voltage range 5–30 V DC
AC load-voltage range 5–250 V AC
Rated output current 2 A per channel
Maximum output group current 8 A per conductor/group
Output protection External short-circuit protection required
Maximum external 24 V supply current 72 mA
Maximum 5 V backplane current 150 mA
Typical power loss 6 W
Relay endurance 10 million mechanical operations; 100000 at rated load voltage
Output cable limit 500 m shielded; 150 m unshielded
Input and output isolation groups Inputs in groups of 8; relay outputs in groups of 4
Insulation test 500 V AC
SIPLUS operating temperature −25 to +70°C; −25 to +55°C for cUL applications
Condensation and chemical exposure Condensation permitted; specified chloric/sulphuric atmospheres
Dimensions 137.5 × 80 × 62 mm (W × H × D)
Approximate weight 400 g
Frequently Asked Questions

How many relay channels does 6AG1223-1PL22-2XB0 provide?

The module provides sixteen relay outputs alongside sixteen digital inputs.

Does 6AG1223-1PL22-2XB0 include short-circuit protection for the relay loads?

The relay output circuits require external short-circuit protection.

Can every relay output of 6AG1223-1PL22-2XB0 carry 2 A without checking its group?

Each channel is rated at 2 A and the current per conductor or output group must also remain within 8 A.

What DC load-voltage range applies to 6AG1223-1PL22-2XB0?

The permitted DC load-voltage range is 5–30 V.

What AC load-voltage range applies to 6AG1223-1PL22-2XB0?

The permitted AC load-voltage range is 5–250 V.

How are the relay circuits of 6AG1223-1PL22-2XB0 isolated?

The relay outputs are isolated in groups of four channels.

What is the maximum ambient temperature for a cUL application of 6AG1223-1PL22-2XB0?

The cUL application temperature ceiling is +55°C.

Compatibility & Ordering Notes
Before ordering 6AG1223-1PL22-2XB0: Match the S7-22X station, relay load voltage, 2 A channel and 8 A group limits, and required SIPLUS environment.

Before installation

  • Use the EM 223 configuration for the S7-22X expansion station.
  • Select external protection for the relay load circuits.
  • Check both individual channel current and the shared group current.
  • Use the specified SIPLUS environmental range and observe the cUL temperature restriction where applicable.
Hot Selling Models
1300062402
3190014
efector100 IW5060 IW-3008-BPKG
7205BE2RZP
734-001 51223646
DSNU-32-25-PPV-A
ABB TA75DU-32
LA9FR703
GB2CD12 021493
RMB12.1-04
3RV2011-1KA20
AC1218
284101 51115517
3NA3 230 100A
IN5130 IN-3004-BPKG

Get a Free Quote

Our representative will contact you soon.
Email
Name
Company Name
Message
0/1000
email goToTop

Evolo Automation is not an authorized distributor unless otherwise specified, representative, or affiliate of the manufacturer of this product. All trademarks and documents are the property of their respective owners and are provided for identification and informational.