Siemens 3VT8110-1AA03-0AA0 VT100 Three-Pole 100 A Circuit Breaker
Manufacturer: Siemens
Condition: Brand New
Lead Time: In Stock
Origin: Germany
Warranty: 12 Months
Email: [email protected]
whatsApp: +86-18150117685
- Overview
- Hot Selling Models
- Recommended Products
Overview
- Confirm three-pole system protection is required.
- Check Ir = 100 A and Ii = 1000 A against the protection design.
- Assess the 25 kA Icu at the applicable AC voltage.
- Match the fixed mounting and screw-terminal arrangement.
- Provide the required auxiliary release and indication functions separately.
3VT8110-1AA03-0AA0 VT100 Three-Pole 100 A Circuit Breaker
A fixed-mounted, three-pole VT100 breaker with a 100 A overload setting and 1000 A short-circuit setting.
At a Glance
| Brand | Siemens |
|---|---|
| Model | 3VT8110-1AA03-0AA0 |
| Product Type | VT100 circuit breaker |
| Core Function | Overload and short-circuit protection |
| Application | Low-voltage power distribution |
Three protected poles
The VT100 breaker provides three-pole system protection.
Thermal-magnetic trip
The specified overload and short-circuit settings are 100 A and 1000 A.
Screw connections
The main circuit uses screw-type terminals.
Product Overview
3VT8110-1AA03-0AA0 provides thermal-magnetic system protection in the VT100 range. This fixed-mounted version has three poles and the Standard N breaking-capacity class.
The article is supplied without an auxiliary release and without auxiliary switches. Its main-circuit connection uses screw terminals, so the existing mounting arrangement, conductor termination and accessory requirements should be checked together.
Key Functions
Protect against overload
The thermal-magnetic trip unit has an overload setting of 100 A.
Interrupt short circuits
The short-circuit setting is 1000 A and the specified ultimate breaking capacity is 25 kA at the stated AC voltages.
Fit the fixed installation
Screw-type main terminals connect the fixed-mounted breaker to the power circuit.
Official Specifications
| Number of poles | 3 |
|---|---|
| Trip-unit technology | Thermal-magnetic |
| Overload setting Ir | 100 A |
| Short-circuit setting Ii | 1000 A |
| Ultimate short-circuit breaking capacity Icu | 25 kA at 400, 415 and 440 V AC |
| Main-circuit connection | Screw-type terminals |
| Mounting arrangement | Fixed-mounted |
| Net weight | 0.92 kg |
Frequently Asked Questions
Which overload and short-circuit settings identify 3VT8110-1AA03-0AA0?
The specified settings are Ir = 100 A for overload protection and Ii = 1000 A for short-circuit protection.
At which AC voltages is the 25 kA Icu of 3VT8110-1AA03-0AA0 stated?
The ultimate short-circuit breaking capacity is 25 kA at 400, 415 and 440 V AC.
Does 3VT8110-1AA03-0AA0 include an auxiliary release?
The article is supplied without an auxiliary release.
Are auxiliary indication switches included with 3VT8110-1AA03-0AA0?
No auxiliary indication switches are included.
Is 3VT8110-1AA03-0AA0 the fixed-mounted version?
This order number identifies a fixed-mounted breaker.
How are the main conductors connected to 3VT8110-1AA03-0AA0?
The main current circuit uses screw-type terminals.
How much net component weight should I allow for 3VT8110-1AA03-0AA0?
The net component weight is 0.92 kg.