Get a Free Quote

Our representative will contact you soon.
Email
Name
Company Name
Message
0/1000
siemens 3rt5036 1an20 sirius 50a 220vac power contactor-0

For SIEMENS

Home >  Products >  For SIEMENS

Siemens 3RT5036-1AN20 SIRIUS 50A 220VAC Power Contactor

Manufacturer: Siemens
Condition: Brand New
Lead Time: In Stock
Origin: Germany
Warranty: 12 Months

  • Overview
  • Hot Selling Models
  • Recommended Products
Overview
SIEMENS SIRIUS 3RT5

3RT5036-1AN20 SIRIUS 50A 220VAC Power Contactor

A size S2 contactor rated 50 A and 22 kW at 400 V AC-3/AC-3e, with a 220 V AC 50/60 Hz coil and screw terminals.

At a Glance

Brand Siemens
Model 3RT5036-1AN20
Product Type AC-operated power contactor
Core Function Motor power-circuit switching
Application Industrial motor starter assemblies

400 V motor duty

Rated 50 A and 22 kW for AC-3 and AC-3e operation.

220 V AC control

The operating coil accepts 220 V AC at 50 or 60 Hz.

Size S2

Screw terminals and screw or 35 mm DIN-rail mounting support panel integration.

Product Overview

3RT5036-1AN20 switches three-phase motor power circuits using three normally open main contacts. Its AC-3 and AC-3e ratings reach 50 A and 22 kW at 400 V, with a size S2 body for industrial starter assemblies.

The control coil is rated 220 V AC at both 50 and 60 Hz. Main, auxiliary and control connections use screw terminals, while the basic unit has no built-in instantaneous auxiliary NO or NC contacts.

Ordering focus: Match the motor utilization category, operating voltage, 220 V AC coil supply and required auxiliary-contact arrangement.
Key Functions

Switch three-phase motor loads

The three main NO contacts carry 50 A at 400 V in AC-3 and AC-3e duty, reducing to 24 A at 690 V.

Operate from an AC control circuit

The coil requires 170 VA apparent pickup power and 15 VA holding power at either 50 or 60 Hz.

Integrate into an S2 starter

The contactor supports side-by-side installation and screw or snap-on mounting on a 35 mm DIN rail.

Official Specifications
Main-contact arrangement 3 NO poles; no NC main contact
AC-3 and AC-3e rated current 50 A at 400 V; 24 A at 690 V
AC-3 and AC-3e motor power 15 kW at 230 V; 22 kW at 400 V; 30 kW at 500 V; 22 kW at 690 V
AC-1 rated current up to 690 V 60 A at 40 °C; 55 A at 60 °C
Control-coil supply 220 V AC, 50/60 Hz
Coil operating-voltage factor 0.8–1.1 at 50 Hz; 0.85–1.1 at 60 Hz
Coil pickup and holding power 170 VA pickup; 15 VA holding
Built-in instantaneous auxiliary contacts 0 NO and 0 NC
Insulation and surge ratings 690 V rated insulation voltage; 6 kV rated impulse withstand
Mechanical service life 10 million operating cycles typical
Maximum AC-3 and AC-3e switching rate 800 operations per hour
Main-circuit short-circuit fuses gL/gG 160 A for coordination type 1; gL/gG 80 A for coordination type 2
Main conductor capacity 2 × 0.75–16 mm² for solid, stranded or fine-stranded conductors
Mounting and terminals Size S2; screw terminals; screw or 35 mm DIN-rail mounting
Operating and storage temperatures Operation: −25 to +60 °C; storage: −55 to +80 °C
Maximum installation altitude 2,000 m above sea level
Front protection IP20; finger-safe for vertical contact from the front
Dimensions and net weight 55 × 112 × 115 mm (W × H × D); 0.84 kg
Official source:Siemens product data sheet
Frequently Asked Questions

Can 3RT5036-1AN20 switch a 22 kW motor on a 400 V supply?

The AC-3 and AC-3e motor rating is 22 kW at 400 V with a rated current of 50 A.

Will the same 50 A rating apply to 3RT5036-1AN20 at 690 V?

The AC-3 and AC-3e current rating at 690 V is 24 A.

Can I operate 3RT5036-1AN20 from a 24 V DC control output?

The fitted coil requires a rated supply of 220 V AC at 50 or 60 Hz.

How much transformer capacity does the coil of 3RT5036-1AN20 require at pickup?

The coil has an apparent pickup demand of 170 VA and a holding demand of 15 VA.

Does 3RT5036-1AN20 include an auxiliary NO contact for a holding circuit?

The basic unit has no built-in instantaneous NO or NC auxiliary contacts.

Which gG fuse corresponds to type 2 coordination for 3RT5036-1AN20?

The main-circuit fuse requirement for type 2 coordination is gL/gG 80 A.

How can I secure 3RT5036-1AN20 to the control-panel backplate?

Use screw mounting or snap the contactor onto a 35 mm DIN rail.

Compatibility & Ordering Notes
Before ordering 3RT5036-1AN20: Coordinate the motor current and utilization category, 220 V AC control supply, short-circuit protection and any separately required auxiliary switch.

Compatibility Checklist for 3RT5036-1AN20

  • Apply the 400 V or 690 V motor-current rating appropriate to the actual circuit.
  • Allow for the 170 VA coil pickup demand.
  • Specify the required auxiliary switch because the basic unit has no instantaneous auxiliary contacts.
  • Keep installation within −25 to +60 °C and at or below 2,000 m altitude.
Hot Selling Models
ABB MS325-0.63
Allen-Bradley 856T-B24C
CAD11.A540.EF AT18F75367/100
8MBM8-4P3 8025630
3RV1031-4EA10
D204TRS
67098
JMYH-5/2-2.3-L-LED
RC-00C
EZN2_004A001 384066
3RH1122-1BB40 3RH1911-1HA22 3RT1916-1DG00
19.24.35/L
CPE14-M1BH-3GLS-QS-8
IF5906 IFK3004BBPKG/US
TV7H236-02z

Get a Free Quote

Our representative will contact you soon.
Email
Name
Company Name
Message
0/1000
email goToTop

Evolo Automation is not an authorized distributor unless otherwise specified, representative, or affiliate of the manufacturer of this product. All trademarks and documents are the property of their respective owners and are provided for identification and informational.