Overview
- Select the control voltage within the rated AC/DC range.
- Size the switched load by its utilization category rather than by thermal contact current alone.
- Protect the auxiliary circuit with the specified 6 A gL/gG fuse.
- Use the permitted conductor cross-sections and 10 mm stripping length for the push-in terminals.
3RQ2000-2AW00 SIRIUS 24–240 V AC/DC Coupling Relay
A wide-voltage coupling relay with one changeover contact, monostable operation and removable push-in terminals in a 22.5 mm housing.
At a Glance
| Brand | Siemens |
|---|---|
| Model | 3RQ2000-2AW00 |
| Product Type | Industrial coupling relay |
| Core Function | Control-signal coupling |
| Application | Industrial control and auxiliary circuits |
Wide-voltage control
The same relay accepts a rated control voltage from 24 to 240 V AC at 50/60 Hz or 24 to 240 V DC.
Monostable changeover output
One changeover contact provides a common terminal with normally closed and normally open switching paths.
Removable push-in connections
Spring-loaded terminals and a 22.5 mm-wide housing support wiring and replacement on a 35 mm DIN rail.
Product Overview
3RQ2000-2AW00 couples a control signal to an electrically separate changeover output using a wide 24–240 V AC/DC control supply.
The monostable relay combines removable push-in terminals with an LED indication and a compact industrial enclosure for cabinet installation.
Key Functions
Wide-voltage control
The same relay accepts a rated control voltage from 24 to 240 V AC at 50/60 Hz or 24 to 240 V DC.
Monostable changeover output
One changeover contact provides a common terminal with normally closed and normally open switching paths.
Removable push-in connections
Spring-loaded terminals and a 22.5 mm-wide housing support wiring and replacement on a 35 mm DIN rail.
Official Specifications
| Rated control supply | 24–240 V AC, 50/60 Hz, or 24–240 V DC |
|---|---|
| Control operating range | 0.7–1.1 times rated control voltage |
| Output contact | 1 changeover; AgSnO2 contact material |
| AC-15 contact duty | 3 A at 24, 110 or 250 V AC |
| DC-13 contact duty | 1 A at 24 V; 0.2 A at 125 V; 0.1 A at 250 V |
| Maximum thermal contact current | 5 A |
| Switching behavior | Monostable |
| Maximum operating delays | 10 ms on-delay; 100 ms off-delay |
| Power consumption | 1.5 W |
| Typical mechanical life | 10 million operating cycles |
| Typical electrical life | 100,000 operations at AC-15, 230 V |
| Rated insulation and impulse withstand | 300 V insulation; 4 kV impulse withstand; pollution degree 3 |
| Required auxiliary-circuit fuse | 6 A, gL/gG |
| Terminal arrangement | Removable spring-loaded push-in terminals |
| Connectable conductors | 0.5–4 mm² solid; 0.5–2.5 mm² finely stranded with ferrule |
| Wire stripping length | 10 mm |
| Mounting | Any position; screw mounting or 35 mm DIN rail |
| Dimensions | 22.5 × 100 × 90 mm |
| Operating temperature | −40 to +60 °C |
| Net weight | 0.123 kg |
Frequently Asked Questions
Will one 3RQ2000-2AW00 variant work with both an AC and a DC control signal?
The rated control supply covers 24–240 V AC at 50/60 Hz and 24–240 V DC.
Can I treat the 5 A marking on 3RQ2000-2AW00 as its DC-13 switching rating?
The 5 A value is the thermal contact current, while DC-13 duty is limited to 1 A at 24 V, 0.2 A at 125 V or 0.1 A at 250 V.
How quickly does 3RQ2000-2AW00 respond when the control signal is removed?
The maximum off-delay is 100 ms.
Can I use 3RQ2000-2AW00 as a latching relay?
The relay is monostable and does not provide a latching switching action.
Which fuse protects the auxiliary contact circuit of 3RQ2000-2AW00?
Use the specified 6 A gL/gG fuse for auxiliary-circuit short-circuit protection.
Can I remove the wiring terminals from 3RQ2000-2AW00 during replacement?
The auxiliary and control connections use removable push-in terminals.
How much insulation should I strip before wiring 3RQ2000-2AW00?
Strip 10 mm of insulation for the auxiliary and control-contact connections.