Overview
SIRIUS 3RQ2

3RQ2000-2AW00 SIRIUS 24–240 V AC/DC Coupling Relay

A wide-voltage coupling relay with one changeover contact, monostable operation and removable push-in terminals in a 22.5 mm housing.

At a Glance

Brand Siemens
Model 3RQ2000-2AW00
Product Type Industrial coupling relay
Core Function Control-signal coupling
Application Industrial control and auxiliary circuits

Wide-voltage control

The same relay accepts a rated control voltage from 24 to 240 V AC at 50/60 Hz or 24 to 240 V DC.

Monostable changeover output

One changeover contact provides a common terminal with normally closed and normally open switching paths.

Removable push-in connections

Spring-loaded terminals and a 22.5 mm-wide housing support wiring and replacement on a 35 mm DIN rail.

Product Overview

3RQ2000-2AW00 couples a control signal to an electrically separate changeover output using a wide 24–240 V AC/DC control supply.

The monostable relay combines removable push-in terminals with an LED indication and a compact industrial enclosure for cabinet installation.

Ordering focus: Match the 24–240 V AC/DC control signal, the load’s AC-15 or DC-13 duty and the one-changeover-contact arrangement.
Key Functions

Wide-voltage control

The same relay accepts a rated control voltage from 24 to 240 V AC at 50/60 Hz or 24 to 240 V DC.

Monostable changeover output

One changeover contact provides a common terminal with normally closed and normally open switching paths.

Removable push-in connections

Spring-loaded terminals and a 22.5 mm-wide housing support wiring and replacement on a 35 mm DIN rail.

Official Specifications
Rated control supply 24–240 V AC, 50/60 Hz, or 24–240 V DC
Control operating range 0.7–1.1 times rated control voltage
Output contact 1 changeover; AgSnO2 contact material
AC-15 contact duty 3 A at 24, 110 or 250 V AC
DC-13 contact duty 1 A at 24 V; 0.2 A at 125 V; 0.1 A at 250 V
Maximum thermal contact current 5 A
Switching behavior Monostable
Maximum operating delays 10 ms on-delay; 100 ms off-delay
Power consumption 1.5 W
Typical mechanical life 10 million operating cycles
Typical electrical life 100,000 operations at AC-15, 230 V
Rated insulation and impulse withstand 300 V insulation; 4 kV impulse withstand; pollution degree 3
Required auxiliary-circuit fuse 6 A, gL/gG
Terminal arrangement Removable spring-loaded push-in terminals
Connectable conductors 0.5–4 mm² solid; 0.5–2.5 mm² finely stranded with ferrule
Wire stripping length 10 mm
Mounting Any position; screw mounting or 35 mm DIN rail
Dimensions 22.5 × 100 × 90 mm
Operating temperature −40 to +60 °C
Net weight 0.123 kg
Frequently Asked Questions

Will one 3RQ2000-2AW00 variant work with both an AC and a DC control signal?

The rated control supply covers 24–240 V AC at 50/60 Hz and 24–240 V DC.

Can I treat the 5 A marking on 3RQ2000-2AW00 as its DC-13 switching rating?

The 5 A value is the thermal contact current, while DC-13 duty is limited to 1 A at 24 V, 0.2 A at 125 V or 0.1 A at 250 V.

How quickly does 3RQ2000-2AW00 respond when the control signal is removed?

The maximum off-delay is 100 ms.

Can I use 3RQ2000-2AW00 as a latching relay?

The relay is monostable and does not provide a latching switching action.

Which fuse protects the auxiliary contact circuit of 3RQ2000-2AW00?

Use the specified 6 A gL/gG fuse for auxiliary-circuit short-circuit protection.

Can I remove the wiring terminals from 3RQ2000-2AW00 during replacement?

The auxiliary and control connections use removable push-in terminals.

How much insulation should I strip before wiring 3RQ2000-2AW00?

Strip 10 mm of insulation for the auxiliary and control-contact connections.

Compatibility & Ordering Notes
Before ordering 3RQ2000-2AW00: Match the 24–240 V AC/DC control signal, the load’s AC-15 or DC-13 duty and the one-changeover-contact arrangement.

Before installation

  • Select the control voltage within the rated AC/DC range.
  • Size the switched load by its utilization category rather than by thermal contact current alone.
  • Protect the auxiliary circuit with the specified 6 A gL/gG fuse.
  • Use the permitted conductor cross-sections and 10 mm stripping length for the push-in terminals.
Hot Selling Models
3RB3016-2SB0
PN7094
ADVU-50-15-APA
CDQSB2510D
Bürkert 1610
MCR-SLP-1-5-UI-0
3RV2901-1E
FS401M C62CCL562010E0064
LP-012-0-WR526-11-1
ADVU-20-10-APA
IM5037 IME2015BFRKG
VAA4EAKF2ZEE2
MXS8-20 0.15-0.7MPa
NLS1-09/5-3 827523
3SB3500-4LD01-ZE:04

Get a Free Quote

Our representative will contact you soon.
Email
Name
Company Name
Message
0/1000
email goToTop

Evolo Automation is not an authorized distributor unless otherwise specified, representative, or affiliate of the manufacturer of this product. All trademarks and documents are the property of their respective owners and are provided for identification and informational.