Overview
SIEMENS AS-Interface K60

3RK2400-1DQ00-0AA3 AS-Interface K60 Four-Input Four-Output Compact Module

An IP67 A/B slave with four digital inputs, four PNP outputs and M12 connections using Y-II pin assignment.

At a Glance

Brand Siemens
Model 3RK2400-1DQ00-0AA3
Product Type Digital field I/O module
Core Function Connecting sensors and actuators to AS-Interface
Application AS-Interface field installations

Four inputs and outputs

Four input channels connect sensors and four PNP channels switch 24 V DC loads.

Actuator current budget

Each output supports 2 A and the combined output current is limited to 4 A.

Field mounting

The IP67 housing mounts using the separately ordered K60 mounting plate.

Product Overview

3RK2400-1DQ00-0AA3 connects field sensors and actuators to an AS-Interface network as a specification 3.0 A/B slave. Eight M12 sockets provide the input and output connections with Y-II pin assignment.

The sensor supply comes from AS-Interface and is protected against overload and short circuit. The PNP outputs are short-circuit protected, with a 2 A channel rating at 24 V DC and a 4 A combined module limit.

Ordering focus: Match the A/B slave configuration, Y-II M12 wiring, sensor supply demand and the combined actuator-current limit.
Key Functions

Collect sensor states

Four DC input channels support two-wire and three-wire sensor connections.

Switch field actuators

Four PNP transistor outputs provide up to 2 A per channel within the 4 A module total.

Distribute field connections

The IP67 K60 module uses M12 screw connections and a separate mounting plate.

Official Specifications
Digital channel allocation 4 inputs and 4 outputs
Slave specification AS-Interface A/B slave, specification 3.0
I/O connectors and pin assignment 8 M12 sockets, Y-II assignment
Sensor-supply source and voltage AS-Interface; 20–30 V
Combined sensor-supply current at 40 °C 200 mA for all inputs
Sensor-supply protection Short-circuit and overload resistant
Sensor connection technology 2-wire or 3-wire
Digital-input current thresholds Signal 1: at least 6 mA; signal 0: at most 1.5 mA
Output switching technology PNP transistor
Per-output rating 2 A at 24 V DC, DC-13
Maximum combined output current 4 A
Output short-circuit protection Integrated
Degree of protection IP67
Operating ambient temperature −25 to +85 °C
Storage temperature −40 to +85 °C
Shock resistance 15 g for 11 ms
Dimensions 60 × 152 × 29 mm (W × H × D)
Frequently Asked Questions

Can all outputs of 3RK2400-1DQ00-0AA3 carry 2 A at the same time?

Each output is rated at 2 A, but their combined current must stay within 4 A.

Which mounting plate should I order with 3RK2400-1DQ00-0AA3?

The required K60 mounting plate is 3RK1901-0CA00 and is ordered separately.

Which M12 assignment should my cables match on 3RK2400-1DQ00-0AA3?

The input and output sockets use Y-II pin assignment.

Can I connect two-wire and three-wire sensors to 3RK2400-1DQ00-0AA3?

The digital inputs support both two-wire and three-wire connection technology.

How much sensor current is available from 3RK2400-1DQ00-0AA3 at 40 °C?

The combined sensor supply for all inputs is limited to 200 mA.

Does 3RK2400-1DQ00-0AA3 provide sinking or sourcing transistor outputs?

The module uses sourcing PNP transistor outputs.

Which AS-Interface slave type should I configure for 3RK2400-1DQ00-0AA3?

The device is an A/B slave conforming to AS-Interface specification 3.0.

Compatibility & Ordering Notes
Before ordering 3RK2400-1DQ00-0AA3: Select the exact K60 A/B module, provide mounting plate 3RK1901-0CA00 and match the Y-II wiring and sensor/actuator current budgets.

Compatibility Checklist for 3RK2400-1DQ00-0AA3

  • Configure an AS-Interface specification 3.0 A/B slave.
  • Match the eight M12 connections to the Y-II pin assignment.
  • Keep total sensor demand within 200 mA at 40 °C.
  • Limit each output to 2 A and the output total to 4 A.
  • Order the separate K60 mounting plate.
Hot Selling Models
MCR-SL-S-1/5-I-DCI-24
6ES5441-4UA14
SAG/B-p34r
XP91048004C
BLE18M-PS-1P-E4-C
RLK6/7c/16/40a/53 9.417073
DA13-NS60/P1R
AREI2X4 /PFB 001 853
08200-L2161-A121
CLR-16-10-LPA
R0003 29-42A
6ES7133-1BL01-0XB0 6ES7193-1CL-10-0XA0 6ES7193-1FL60-0XA0
13527222
MVH-5/3E-1/4 B-VI
HSR25A1SS(GK) 202A25122000000

Get a Free Quote

Our representative will contact you soon.
Email
Name
Company Name
Message
0/1000
email goToTop

Evolo Automation is not an authorized distributor unless otherwise specified, representative, or affiliate of the manufacturer of this product. All trademarks and documents are the property of their respective owners and are provided for identification and informational.