SICK LMS1xx LMS100 2D LiDAR Sensor LMS100-10000
Manufacturer: SICK
Condition: Brand New
Lead Time: In Stock
Origin: Germany
Warranty: 12 Months
Email: [email protected]
whatsApp: +86-18150117685
- Overview
- Product Overview
- Key Functions
- Official Specifications
- Frequently Asked Questions
- Compatibility & Ordering Notes
- Hot Selling Models
- Recommended Products
Overview
SICK • LMS1xx
LMS100-10000 LMS1xx LMS100 2D LiDAR Sensor
The SICK LMS100 is an indoor 2D LiDAR sensor with a 270-degree scanning field, configurable field evaluation and Ethernet-based commissioning for industrial detection tasks.
At a Glance
| Brand | SICK |
|---|---|
| Model | LMS100-10000 |
| Product Type | Indoor 2D LiDAR sensor |
| Core Function | Measures surrounding profiles and evaluates configurable monitoring fields |
| Application or Compatible Series | Indoor object detection, area monitoring and positioning applications |
Exact Identification
Match LMS100-10000 character by character and confirm the complete LMS1xx LMS100 2D LiDAR Sensor designation.
Interface Arrangement
Confirm the installed supply, ports, field connections and required accessories before wiring the replacement.
Configuration Check
Preserve the approved engineering project, network parameters and application data used by the installed system.
Product Overview
The SICK LMS100 is an indoor 2D LiDAR sensor with a 270-degree scanning field, configurable field evaluation and Ethernet-based commissioning for industrial detection tasks.
A 270-degree aperture and selectable scan settings capture surrounding contours for indoor automation tasks. Ten field sets and ten simultaneous evaluation cases support configurable monitoring logic. Ethernet, RS-232 and CAN-based expansion options integrate measurement data and switching results.
Key Functions
Wide-Angle Laser Scanning
A 270-degree aperture and selectable scan settings capture surrounding contours for indoor automation tasks.
Integrated Field Evaluation
Ten field sets and ten simultaneous evaluation cases support configurable monitoring logic.
Industrial Communication
Ethernet, RS-232 and CAN-based expansion options integrate measurement data and switching results.
Official Specifications
| Application Environment | Indoor |
|---|---|
| Light Source | Infrared laser, 905 nm |
| Laser Class | Class 1 |
| Scanning Aperture | 270° |
| Scan Frequency | 25 Hz or 50 Hz |
| Angular Resolution | 0.25° or 0.5° |
| Working Range | 0.5 to 20 m |
| Range at 10% Remission | 18 m |
| Range at 90% Remission | 20 m |
| Echo Evaluation | 2 echoes |
| Response Time | 20 ms minimum |
| Systematic Measurement Error | ±30 mm |
| Statistical Measurement Error | 12 mm |
| Supply Voltage | 10.8 to 30 V DC |
| Power Consumption | 22 W |
| Ethernet Interface | TCP/IP, 10/100 Mbit/s |
| Serial Interface | RS-232, 9.6 to 115.2 kBaud |
| Degree of Protection | IP65 |
| Dimensions | 105 x 102 x 152 mm |
| Weight | 1.1 kg |
Frequently Asked Questions
Is LMS100-10000 suitable for outdoor use?
No; use it in an indoor installation within the specified temperature, light and enclosure conditions.
What area can LMS100-10000 scan?
The sensor covers a 270-degree field with a working range from 0.5 to 20 m.
Which network is used to commission LMS100-10000?
Use the 10/100 Mbit/s Ethernet TCP/IP interface with the assigned network parameters.
Can LMS100-10000 evaluate several monitoring fields at once?
Yes; configure up to ten field sets and ten simultaneous evaluation cases for the application.
Does LMS100-10000 require a separate safety controller?
Yes; it is not a safety component and must not be used as the sole protective device for personnel.
What should be backed up before replacing LMS100-10000?
Save the field sets, evaluation cases, filters, scan configuration, IP settings and I/O assignments.
What should be tested after installing LMS100-10000?
Verify alignment, reference contours, blind-zone clearance, field switching, outputs and measurement stability across the full monitored area.
Compatibility & Ordering Notes
Compatibility Checklist
- Use only for indoor applications within the specified environmental limits.
- Preserve the commissioned field geometry and Ethernet configuration.
- Do not use the sensor as a personnel-protection safety device.