Manufacturer: Schneider Electric
Condition: Brand New
Lead Time: In Stock
Origin: France
Warranty: 12 Months

  • Overview
  • Hot Selling Models
  • Recommended Products
Overview
Altivar 11

ATV11HU41M3A Altivar 11 2.2 kW Three-Phase Drive

Asian-range Altivar 11 rated at 2.2 kW, with a 10 A nominal output, 15 A transient current and programmable analog and logic signals.

At a Glance

Brand Schneider Electric
Model ATV11HU41M3A
Product Type Variable-speed motor drive
Core Function Adjustable-speed motor operation
Application 200–230 V three-phase motor systems

2.2 kW motor channel

The Asian-range output is rated at 10 A with up to 15 A transient current for sixty seconds.

Programmable command signals

A configurable analog input and four logic inputs support local control arrangements.

Adjustable switching behavior

The 2–16 kHz switching range allows the application to balance switching behavior against the required output-current derating.

Product Overview

ATV11HU41M3A provides adjustable-speed control for a three-phase motor in the Altivar 11 Asian range.

The drive combines sensorless flux-vector control, programmable analog and logic signals and configurable switching frequency, with output-current derating applied for higher switching frequencies and elevated ambient temperatures.

Ordering focus: Match the Asian-range 10 A output rating, three-phase mains supply, motor data and temperature-dependent current allowance.
Key Functions

2.2 kW motor channel

The Asian-range output is rated at 10 A with up to 15 A transient current for sixty seconds.

Programmable command signals

A configurable analog input and four logic inputs support local control arrangements.

Adjustable switching behavior

The 2–16 kHz switching range allows the application to balance switching behavior against the required output-current derating.

Official Specifications
Motor power rating 2.2 kW / 3 hp
Mains supply 3-phase 200–230 V AC, −15%/+15%
Supply frequency 50 Hz ±5% or 60 Hz ±5%
Input line current 15.2 A at the 200 V nominal Asian-range condition
Nominal output current 10 A
Transient output current 15 A for 60 s
Short-circuit rating 5 kA for the specified three-phase supply
Power dissipated at nominal load 94 W
Output frequency 0–200 Hz
Switching frequency 2–16 kHz; continuous power ratings based on 4 kHz
High-frequency current derating 10% at 8 kHz; 20% at 12 kHz; 30% at 16 kHz
Control technique Sensorless flux-vector control with PWM
Programmable analog input 1; 0–5 V, 0–10 V, 0–20 mA or 4–20 mA
Logic inputs 4 programmable inputs; internal 15 V or external 24 V supply
Relay contact capacity 5 A resistive or 2 A inductive at 250 V AC or 30 V DC
Degree of protection IP20
Operating ambient −10 to +50°C with top protective cover removed; up to +60°C with 2.2% current derating per °C above +50°C
Storage ambient −25 to +69°C
Relative humidity 5–93%, noncondensing and without dripping
Altitude allowance 1000 m without derating; 1% current derating per additional 100 m
Frequently Asked Questions

Can I connect ATV11HU41M3A to a single-phase mains supply?

The M3A drive requires the specified three-phase 200–230 V AC supply.

Should I use the North American 10.6 A rating when setting up ATV11HU41M3A?

The Asian-range drive has a nominal output-current rating of 10 A.

Can ATV11HU41M3A continuously deliver full rated current at 16 kHz switching?

Continuous operation at 16 kHz requires a thirty-percent current derating from the 4 kHz rating.

Which external braking arrangement can I use with ATV11HU41M3A?

The specified external VW3A11701 braking module uses a resistor of at least 51 Ω for this drive rating.

Can I configure negative-logic inputs on ATV11HU41M3A?

Negative logic is programmable on the Asian-range drive.

Can a 4–20 mA transmitter connect directly to the analog input of ATV11HU41M3A?

The analog input supports 4–20 mA with a 250 Ω input impedance and no added resistance.

How should I size the load when operating ATV11HU41M3A above +50°C?

Derate current by 2.2% per degree above +50°C up to +60°C and apply the specified top-cover removal condition.

Compatibility & Ordering Notes
Before ordering ATV11HU41M3A: Match the Asian-range 10 A output rating, three-phase mains supply, motor data and temperature-dependent current allowance.

Before installation

  • Use the Asian-range current ratings and the intended three-phase supply.
  • Enter the motor data and configure the analog or logic command arrangement.
  • Apply both switching-frequency and ambient-temperature current derating where required.
  • Select the optional braking module, resistor and thermal protection as a matched installation.
Hot Selling Models
3RT2015-1CK64-3MA0
CXSL15-10
LC1D18BD TeSys - 035477
SZ4315.400
OP320A
3RK1901-1NR00
3431.030
ADN2080IPA
4140-840