The 1791-N4V2 Block I/O module combines four configurable analog inputs with two isolated ±10 V outputs in a compact remote-I/O enclosure.

At a Glance

Brand Allen-Bradley
Model 1791-N4V2
Product Type Remote analog input and voltage output block
Core Function Acquires four analog inputs and provides two isolated voltage outputs
Application or Compatible Series Remote I/O systems using Allen-Bradley 1791 analog blocks

Exact Identification

Match 1791-N4V2 character by character and confirm the complete 1791 Block I/O Analog Module designation.

Interface Arrangement

Confirm the installed supply, ports, field connections and required accessories before wiring the replacement.

Configuration Check

Preserve the approved engineering project, network parameters and application data used by the installed system.

Product Overview

The 1791-N4V2 Block I/O module combines four configurable analog inputs with two isolated ±10 V outputs in a compact remote-I/O enclosure.

Four configurable input channels and two voltage outputs combine measurement and control in one remote block. Fourteen-bit conversion supports precise analog acquisition and output control. The module accepts AC power and supplies the documented 24 V DC loop-power output.

Ordering focus: confirm the complete catalog number, Remote I/O addressing, input ranges, ±10 V output wiring, AC supply and controller configuration.
Key Functions

Mixed Analog Channels

Four configurable input channels and two voltage outputs combine measurement and control in one remote block.

High-Resolution Conversion

Fourteen-bit conversion supports precise analog acquisition and output control.

Integrated Field Power

The module accepts AC power and supplies the documented 24 V DC loop-power output.

Official Specifications
Analog Inputs 4 configurable channels
Analog Outputs 2 voltage channels
Conversion Resolution 14 bit
Input Bandwidth 5 Hz
Input Update Time 108 ms for all four channels
Voltage Input Impedance 10 MΩ
Current Input Impedance 249 Ω
Absolute Accuracy at 25 °C 0.1%
Linearity 0.05%
Output Range ±10 V
Output Impedance Less than 1 Ω
Internal Output Update 10 ms per channel
AC Supply 85 to 132 V AC, 47 to 63 Hz, 150 mA
Loop Supply Output 20 to 28 V DC, 100 mA
Isolation Test Voltage 500/1000 V AC
Power Dissipation 16.9 W
Operating Temperature 0 to 60 °C
Storage Temperature -40 to +85 °C
Relative Humidity 5% to 95% non-condensing
Dimensions 176.5 x 68.8 x 98 mm
Frequently Asked Questions

How many field channels are available on 1791-N4V2?

The block provides four configurable analog inputs and two isolated voltage outputs.

What output range is supported by 1791-N4V2?

Each analog output provides a ±10 V range.

Can 1791-N4V2 accept both voltage and current inputs?

Yes; the four input channels can be configured for the supported voltage or current signals.

What external power is required for 1791-N4V2?

Provide 85 to 132 V AC at 47 to 63 Hz within the stated current rating.

Does 1791-N4V2 provide transmitter loop power?

Yes; a 20 to 28 V DC, 100 mA loop supply output is available.

How fast does 1791-N4V2 update its input data?

All four input channels are updated in 108 ms.

What should be recorded before replacing 1791-N4V2?

Record the input ranges, output scaling, remote-I/O addressing, field wiring and controller configuration.

Compatibility & Ordering Notes
Before ordering 1791-N4V2: confirm the complete catalog number, Remote I/O addressing, input ranges, ±10 V output wiring, AC supply and controller configuration.

Compatibility Checklist

  • Use the block only in an Allen-Bradley Remote I/O architecture that supports its rack and group assignment.
  • Match every input range, output scale and wiring terminal to the existing configuration.
  • Verify isolation, shielding and loop-power loading before energizing the replacement.
Hot Selling Models
TCP5 10/1A
3RV1021-1AA15
3RV1421-1EA10
FSU2
3RU1116-1GC1
5TE8 313
PKZM0-10 NHI11-PKZ0
XTRE10B31
DILM15-10 M12-XSPR240
3RV1021-1EA15
PKZM1-1
NCN40
5SY4210-6
6SE6400-0GP00-0CA0
6ES7121-1BB00-0AA0

Get a Free Quote

Our representative will contact you soon.
Email
Name
Company Name
Message
0/1000
email goToTop

Evolo Automation is not an authorized distributor unless otherwise specified, representative, or affiliate of the manufacturer of this product. All trademarks and documents are the property of their respective owners and are provided for identification and informational.