Get a Free Quote

Our representative will contact you soon.
Email
Name
Company Name
Message
0/1000
siemens 7km2112 0ba00 3aa0 sentron pac3200 power monitoring device-0

For SIEMENS

Home >  Products >  For SIEMENS

Siemens 7KM2112-0BA00-3AA0 SENTRON PAC3200 Power Monitoring Device

Manufacturer: Siemens
Condition: Brand New
Lead Time: In Stock
Origin: Germany
Warranty: 12 Months

  • Overview
  • Hot Selling Models
  • Recommended Products
Overview
SENTRON • PAC3200 Power Monitoring

7KM2112-0BA00-3AA0 SENTRON PAC3200 Power Monitoring Device

PAC3200 panel meter with LCD, 1 A/5 A current inputs, wide-range AC/DC supply and integrated Modbus TCP over RJ45.

At a Glance

Brand Siemens
Model 7KM2112-0BA00-3AA0
Product Type Power monitoring device
Core Function Three-phase electrical measurement and energy monitoring
Application Stationary indoor switchboards and distribution panels

Electrical measurement

Measures voltage, current, active and reactive power, frequency and energy for distribution-system monitoring.

Ethernet integration

The integrated RJ45 interface supports Modbus TCP; optional modules add the listed Modbus RTU, PROFINET or PROFIBUS connections.

Local indication and pulses

A white-backlit LCD with four operating keys is combined with one digital input and one switching or pulse output.

Product Overview

7KM2112-0BA00-3AA0 measures electrical quantities and energy in three-phase distribution systems, presenting values on an LCD and making them available through integrated Modbus TCP communication.

The wide-range auxiliary supply, 96 mm panel format and screw terminals support switchboard integration, while current-transformer ratios and voltage connection settings must match the installation.

Ordering focus: Match the voltage connection, 1 A or 5 A current-transformer secondary and auxiliary supply; order any required fieldbus expansion separately.
Key Functions

Electrical measurement

Measures voltage, current, active and reactive power, frequency and energy for distribution-system monitoring.

Ethernet integration

The integrated RJ45 interface supports Modbus TCP; optional modules add the listed Modbus RTU, PROFINET or PROFIBUS connections.

Local indication and pulses

A white-backlit LCD with four operating keys is combined with one digital input and one switching or pulse output.

Official Specifications
Auxiliary supply 95–240 V AC or 110–340 V DC
Rated voltage measurement 400 V line-to-neutral; 690 V line-to-line
Voltage measurement range 40–480 V line-to-neutral; 70–831 V line-to-line
Current input ratings 1 A or 5 A AC
Relative current measurement range 10–120% of rated input current
Measured line frequency 45–65 Hz with automatic detection
Voltage / current measurement error ±0.3% / ±0.2%
Active-energy accuracy Class 0.5 according to IEC 62053-22
Reactive-energy accuracy Class 2 according to IEC 61557-12 / IEC 62053-23
Integrated communication 1 RJ45 interface with Modbus TCP
Display / operating keys LCD, 72 × 54 mm display, white backlight; 4 keys
Digital I/O 1 input and 1 switching or pulse output
Digital output limits Maximum 30 V DC and maximum 27 mA at signal 1
Pulse-output duration 30–500 ms; maximum switching frequency 17 Hz
Measurement connection Screw-type terminals
Front protection / installed protection class IP65 / Class II
Dimensions / installation depth 96 × 96 × 56 mm / 51 mm
Mounting position Vertical
Operating temperature / humidity −10 to +55 °C / maximum 95% at 25 °C, non-condensing
Maximum installation altitude 2,000 m
Official source:Siemens PAC3200 data sheet
Frequently Asked Questions

Which transformer secondary ratings can be used with 7KM2112-0BA00-3AA0?

The current inputs support rated AC secondary currents of either 1 A or 5 A.

Does 7KM2112-0BA00-3AA0 require a separate module for Modbus TCP?

Modbus TCP is available through the integrated RJ45 interface.

Can 7KM2112-0BA00-3AA0 connect directly to a PROFINET network?

PROFINET requires the appropriate optional communication module rather than using the standard Modbus TCP connection alone.

What auxiliary supply can power 7KM2112-0BA00-3AA0?

The wide-range supply accepts 95–240 V AC or 110–340 V DC.

How much depth is required behind the panel for 7KM2112-0BA00-3AA0?

The specified installation depth is 51 mm within an overall housing depth of 56 mm.

Can 7KM2112-0BA00-3AA0 issue energy pulses?

Its digital output can operate as a pulse output with a selectable duration of 30–500 ms.

Is 7KM2112-0BA00-3AA0 intended for an exposed outdoor installation?

The device is specified for stationary panels in closed rooms, with IP65 protection on the front.

Compatibility & Ordering Notes
Before ordering 7KM2112-0BA00-3AA0: Match the voltage connection, 1 A or 5 A current-transformer secondary and auxiliary supply; order any required fieldbus expansion separately.

Before installation

  • Set the transformer ratios and voltage connection arrangement to match the actual circuit.
  • Distinguish the measured voltage circuits from the separate auxiliary power supply.
  • Include the required communication expansion module when ordering Modbus RTU, PROFINET or PROFIBUS connectivity.
  • Observe the indoor panel-mounting requirements, vertical orientation and environmental limits.
Hot Selling Models
SZT72-S
IRV2W
NZ1VZ538EM
X4VP4
P1MO/220VAC/2U #479865 479 865
GV2ME203
3RH2140-2HB40
ABB S701-E35
PKZM0-4-T XTPT004BC1
Acti9 iCT A9C20844
SMTO-1-PS-S-LED-24C
HG IL 522
57.506.0055.0
400/600 047961-104401
3N3001501

Get a Free Quote