Get a Free Quote

Our representative will contact you soon.
Email
Name
Company Name
Message
0/1000
mitsubishi electric qx10 melsec q 16 point ac input module-0

Others

Home >  Products >  Others

Mitsubishi Electric QX10 MELSEC-Q 16-Point AC Input Module

Manufacturer: Mitsubishi Electric
Condition: Brand New
Lead Time: In Stock
Origin: China
Warranty: 12 Months

  • Overview
  • Hot Selling Models
  • Recommended Products
Overview
MITSUBISHI ELECTRIC MELSEC-Q

QX10 MELSEC-Q 16-Point AC Input Module

A 16-point AC input module for 100–120 V AC signals, with one common group, photocoupler isolation and an 18-point screw terminal block.

At a Glance

Brand Mitsubishi Electric
Model QX10
Product Type AC input module
Core Function Acquisition of AC field-switch states
Application MELSEC-Q controller stations

100–120 V AC

The input circuit is designed for 50 or 60 Hz AC signals.

16-point group

All sixteen inputs share common terminal TB17.

Local indication

Individual LEDs show the input ON state.

Product Overview

QX10 acquires sixteen AC input signals in a MELSEC-Q controller station. It uses a photocoupler input circuit and an 18-point terminal block, with sixteen inputs assigned to one common.

The module occupies sixteen input points in the I/O assignment. Signal-device selection needs to account for the ON and OFF thresholds, frequency-dependent input current, switching delay and the simultaneous-input derating curve.

Ordering focus: Match 100–120 V AC field signals and the 16-point input assignment, then coordinate leakage current, terminal wiring and simultaneous-input loading.
Key Functions

Acquire AC switching states

The inputs accept 100–120 V AC at 50/60 Hz, with ON recognition from 80 V AC and 5 mA.

Interface through a terminal block

The 18-point screw terminal block assigns TB1–TB16 to the inputs and TB17 to common.

Indicate channel activity

Input LEDs turn on when the corresponding input state is ON.

Official Specifications
Input points and common 16 inputs; 16 points per common at TB17
Rated input supply 100–120 V AC, +10/−15%; 50/60 Hz ±3 Hz
Maximum input-voltage distortion 5%
Rated input current at 100 V AC Approximately 8 mA at 60 Hz; 7 mA at 50 Hz
Maximum inrush current 200 mA within 1 ms at 132 V AC
ON threshold At least 80 V AC and 5 mA
OFF threshold No more than 30 V AC and 1.7 mA
Input impedance Approximately 12 kΩ at 60 Hz; 15 kΩ at 50 Hz
Maximum response time OFF to ON: 15 ms; ON to OFF: 20 ms at 100 V AC, 50/60 Hz
Input isolation Photocoupler
Dielectric withstand voltage 1,780 V AC rms for 3 cycles at 2,000 m altitude
Insulation resistance At least 10 MΩ
External terminal block 18-point screw terminal block
Applicable conductor size 0.3–0.75 mm²; maximum outside diameter 2.8 mm
Applicable crimp terminal R1.25-3; sleeved crimp terminals cannot be used
Occupied I/O allocation 16 input points
Internal 5 V DC current 50 mA typical with all points ON
Module weight 0.17 kg
Frequently Asked Questions

Can I connect a 24 V DC proximity sensor directly to QX10?

The input circuit is rated for 100–120 V AC rather than 24 V DC.

Which terminal is common for the sixteen inputs on QX10?

All sixteen input points share common terminal TB17.

Will a 10 ms AC pulse always be captured by QX10?

The OFF-to-ON response can take up to 15 ms at 100 V AC and 50 or 60 Hz.

What residual voltage must a field switch stay below to turn QX10 off?

The OFF condition requires no more than 30 V AC and 1.7 mA.

Can I use insulated-sleeve crimp terminals on QX10?

The specified R1.25-3 crimp terminals must be used without an insulating sleeve.

How many controller input addresses should I reserve for QX10?

Assign the module as a sixteen-point input module.

Can I keep all inputs of QX10 on at any cabinet temperature?

The permitted simultaneous ON ratio depends on the input voltage and ambient temperature and must remain within the module’s derating curve.

Compatibility & Ordering Notes
Before ordering QX10: Select the AC input version for the MELSEC-Q station and coordinate field-voltage range, I/O allocation and terminal accessories.

Compatibility Checklist for QX10

  • Use the 100–120 V AC, 50/60 Hz input rating.
  • Reserve sixteen input points.
  • Use 0.3–0.75 mm² conductors and the permitted unsleeved crimp terminals.
  • Apply the simultaneous-input derating curve at the actual voltage and temperature.
Hot Selling Models
ZK1090-3131-0016
FLKM-D15 SUB/S 2281131
7003921BM01
3RT2017-1BB41
IFR122415
12.24.45/K438
93/A-60L
WT12-P4381 1011 017
DSNU-12-20-PA
DF2CN06 050210 FR10G 50V6
MK13-P-Ex0/24VDC/K15
SK3240.200
FAZ-C8/3
7000-88011-6310040
KG20A T306 / D-A058 VE2