- Conspectus
- Specificationes
- Descriptio
- Usus
- Eigenschaften
- Special handling
- REPARATIO/SUBSTITUTIO
- FAQ
- Producta Commendata
Conspectus
Locus originis: |
Suecia |
Nomen marcae: |
ABB |
Numerus exemplaris: |
IMDSM04 |
Particularia impaquetandi: |
Originales nova Officina Sigillata |
Tempus solutionis: |
5-7 dies |
Conditiones solutionis: |
T/T |
Vis Supplicandi: |
In stirpe |
Specificationes
|
Parameter |
Valor |
|
Formam |
IMDSM04 |
|
Descriptio |
Modulus Auxiliaris Inputus Pulsuum |
|
Tensiones Alimentationis |
alimentatio Logica ±5 VDC (±5%); Alimentatio I/O ±24 VDC (+12%, -10%) |
|
Consumptio currentis |
5 VDC: 1,4 A typice, 1,5 A maxime; 24 VDC: 62 mA typice, 70 mA maxime |
|
Tensiones Inputus |
Intervalum 1 (5 VDC): 4,0–6,0 VDC; Intervalum 2 (24 VDC): 21,6–27,0 VDC; Intervalum 3 (Praeamplificatores): 50 mV–10 V pico-ad-picum |
|
Maxima Currus Signi Inputus |
Intervalus 1: 14,8 mA ad 6 VCC; Intervalus 2: 8,4 mA ad 24 VCC; Intervalus 3: 0,4 mA ad 10 V pico-ad-picum |
|
Tensiones Intrantis Logicae 1 |
Intervalus 1: 4–6 VCC; Intervalus 2: 21,6–27 VCC; Intervalus 3: 25 mV–5 V pico-ad-picum |
|
Tensiones Intrantis Logicae 0 |
Intervalus 1: 0–1 V; Intervalus 2: 0–2 V; Intervalus 3: −5 mV usque ad −25 mV pico-ad-picum |
|
Tempora Debounce |
IN: 8,5 ms (typice); EX: 8,5 ms (typice) |
|
Limites Frequentiae Signi Intrantis |
Frequenta superior utendi debounce: 40 Hz |
|
Accuratio Modi |
Totalizare: ±0 numerationes; Numeratio frequentiae: ±1 numeratio; Determinatio periodi: ±1 numeratio |
|
Frequentia maxima admissa |
50 kHz (ciclus operis 50%) |
|
Accuratio temporis basis |
±0.033% |
|
Tensio Isolationis |
150 V RMS inter canales; 350 V RMS inter introitus et logicam |
|
Resistentia Ad Impulsus |
Adimplet normam IEEE de capacitate ad impulsus 472-1974 in omnibus introitibus debounced |
|
Recomendatio pro EMI/RFI |
Mantinete fores arcae clausas; servate distantiam ≥2 m ab apparatibus communicationis |
|
Temperatura operativa |
0° ad 70°C (32° ad 158°F) |
|
Humiditas relativa |
5 % ad 95 % usque ad 55°C; 5 % ad 45 % ad 70°C (sine condensatione) |
|
Pressura atmosphaerica |
Nivel maris ad 3 km (1,86 milia passuum) |
Descriptio
IMDSM04 unam tabulam circuitus impressi habet, quae unum locum in Unitate Montis Modulorum (MMU) occupat. Duo clavuli captivi in facie moduli DSM ad MMU firmantur. Modulus servus tres connexiones marginis cartae pro signis externis et potestate habet. P1 ad communes (terram) et +5 VDC potestatem connectitur. P2 modulum ad omnibus servis expansionis (slave expander bus) connectit, ut cum modulo magistro communicet (vide Tabulam 5-2). Signa pulsuum per conectorum P3 intrant, ut cavo ad Unitatem Terminalem (TU) vel Modulum Terminalem (TM) coniuncto (vide Tabulam 5-3). Impedimenta terminalia (puncta connexionis physicae) pro filis agrestibus in TU/TM sunt. Unumquodque introitum ad 4–6 VDC aut ad 21,6–27 VDC respondere potest, necnon ad frontem ascendentem aut descendentem signi. Praeterea, canales 1 et 2 per praecrescentes (preamplifiers) diriguntur, ut ad introitus a 50 mV (ad apicem ad apicem) ad 10 V (ad apicem ad apicem) respondeant.
Informationes de constitutione DSM in MFP inseruntur per codices functionum. Utere aut modulo sintonizationis configurationis aut unitate interfaciei operatoris. Codices functionum tres modos operationis DSM incipiunt. Hi tres modi operationis sunt: Totalizatio, Frequentia, aut Periodus.
Usus
1. Centralia Electricitatis
Hoc est cor huius seriei modulorum:
Centralia electricitatis carbonaria (generatio electricitatis ex carbone, gas, et biomassa)
Centralia electricitatis nuclearia (regulatio insulae conventionalis non ad gradum tutelae)
Centralia electricitatis cum cogeneratione (praebens calefactionem urbanam et vaporem industrialem)
Centralia electricitatis hydraulicæ (regulatio velocitatis unitatis et supervisio)
2. Plantae Olei, Gas et Chemicarum
Refineriae olei (tractatio petrolei crudis, unitates fissurae)
Plantae fertilium (synthesis ammoniaci, productio ureae)
Fabricae pro elaboratione gas naturalis et stationes ad comprimendum
Fabricae chemicorum subtilium (reactores et controllum compositionis)
3. Fabricae magnae fabricationis
Molendina chartaria et molendina ligni (magnae machinae pro fabricando charta, lineae productionis pro elaborando ligno)
Molendina ferri et fabricae metallurgicae (furni blast, fornaces pro coquendo coke, lineae continuas pro laminando)
Fabricae caementi (furni rotativi, controllum molarum)
Fabricae mineralium et beneficiendarum (translatio materiae, frangendi et filtrandi)
4. Fabricae urbanae et publicae
Magnae fabricae pro tractando aquas sordidas
Aquaeductus et stationes pumpantes
Plantae ad energiam ex sordibus
Eigenschaften
IMDSM04 est Modulus Auxiliaris Impulsuum qui datam praebet Processori Multiplici Infi 90 (MFP). DSM condicionat, convertit et tractat impulsus tales ut impulsus amplitudinis humilis, undae sinus, impulsus gradus logici, aut clausurae contactuum in signa digitalia. Applicationes DSM includunt: metras fluxus turbinum, tachometra, vatimetra, sensus propinquitatis et numeratores. Unus servus octo impulsum aut frequentialium ingressuum independens ad modulum magistrum praebet. Signa ingressus sunt optice isolata. DSM etiam interfacit cum praesentibus Controlleribus Multiplicibus Network 90 (MFC). Designatio modularis DSM, sicut omnium modulorum Infi 90, flexibilitatem praebet dum strategia systematis administrationis processus creatur. Octo signa impulsuum separata in tribus intervallis tensionis admittit. Duo intervalla sunt 4 ad 6 VDC et 21,6 ad 27 VDC (intervallum 21,6 ad 27 VDC permittit connexionem ingressuum contactuum aridorum). Tertium intervallum est ad praecipuos amplificatores in canalibus 1 et 2 (pro impulsibus humilis amplitudinis inter 50 millovoltia et 10 voltia pico ad picum). DSM connectit ingressus ad systema Infi 90 sine converteribus separatis.
Special handling
Modulus Servus Intratae Pulsuum (DSM) instrumentis electrostaticis sensibilibus utitur. Sequere Gradus 1 usque ad 4 dum manibus tractas:
1. Serva modulum in eius speciali sacculo anti-statico donec ad instaliendum in systemate paratus sis,
sacculum serva ad usum futurum.
2. Terra sacculum anti-staticum antequam aperias.
3. Verifica ut omnia instrumenta, quae ad modulum sunt connecta, sint
4. Evita tangere circuitus dum modulum manibus tractas.
4.Evita circuitus tangere dum modulum manibus tractas.
REPARATIO/SUBSTITUTIO
Si DSM vitiosus est, eum novo substitue. NE coneris modulum reparare; componentium substitutio moduli functionem laedere potest. Modulum removere licet dum systema adhuc potestate alitur. Ut modulum substituas:
1. Premere et semel dimidium convertere duas vitreas vitarum ante fasciam in captivitate retinentes. Modulus autem solvitur, cum fissurae in vitris verticaliter posita sunt et apertus finis fissurarum a modulo aversus est.
2. Modulum leniter ex MMU extrahere.
3. Configura commutatorum et iuncturarum positiones in modulo substituto. Certior fieri debes eas easdem esse quae in modulo originali.
4. In eodem loco quo modulus originalis erat, modulem substitutum ad plasticas vias directrices in MMU apta. Leniter illud intra, donec tabula anterior aequa sit cum summo et imo structurae MMU.
5. Premere et vertere duas vitarum retentivarum in facie moduli semel ad dimidiam conversionem ad positionem clausae. Clusum est, cum fissurae in vitis verticaliter stant et apertae partes ad centrum moduli spectant. (Ad modulum removendum, vitis retentivae moduli ad positionem non clausae vertuntur et modulus leniter extrahitur.)
6. Ad operationem normalem redeas.
FAQ
Q: Quid est IMDSM04?
A: Est Modulus Auxiliaris Impulsuum.
Q: Quae est vestra tempus expeditionis IMDSM04?
A: Ut in genere dicatur, 1–3 diēs post acceptam solūtiōnem. Tempus expēditīōnis praecīsum pendet ex genere et quantitāte ordinis.
Q: Quanto tempore durat garantia IMDSM04?
A: Unum annum garāntiae standardem omnibus novīs et originālibus prōductīs praebēmus.
Q: Num aliquās dēductiōnēs offertis?
A: Ita! Pro redutionibus in IMDSM04, quaeso Iohannem ad optimam offertam contacteris.