siemens 6es7144 4ff01 0ab0 simatic et 200pro 4ai u high feature voltage input module-0

For SIEMENS

Home >  Products >  For SIEMENS

Siemens 6ES7144-4FF01-0AB0 SIMATIC ET 200pro 4AI U High Feature Voltage Input Module

Manufacturer: Siemens
Condition: Brand New
Lead Time: In Stock
Origin: Germany
Warranty: 12 Months

  • Overview
  • Hot Selling Models
  • Recommended Products
Overview
SIMATIC ET 200pro • High Feature Analog Inputs

6ES7144-4FF01-0AB0 SIMATIC ET 200pro 4AI U High Feature Voltage Input Module

Four High Feature voltage inputs for ±10 V, 0–10 V, ±5 V and 1–5 V measurement, with a bus module included and an IO connection module ordered separately.

At a Glance

Brand Siemens
Model 6ES7144-4FF01-0AB0
Product Type Analog voltage input module
Core Function Acquiring voltage signals with channel diagnostics
Application Decentralized ET 200pro analog measurement

Selectable voltage ranges

Supports ±10 V, 0–10 V, ±5 V and 1–5 V input ranges across four analog inputs.

Measurement filtering

Configurable smoothing uses none, low, medium or high settings corresponding to 1, 4, 16 or 64 measurement cycles.

Channel diagnostics

Diagnostic alarms can be parameterized, with wire-break and short-circuit detection available in the 1–5 V range and a limit interrupt configurable for channel 0.

Product Overview

6ES7144-4FF01-0AB0 acquires four analog voltage signals in an ET 200pro station, combining selectable bipolar and unipolar input ranges with parameterized diagnostics.

Selectable integration and smoothing settings allow the measurement behavior to be matched to the process, while the IO connection module and signal shielding must suit the installed wiring.

Ordering focus: Select the required voltage range and integration setting, order the matching 6ES7194-4..00-0AA0 IO connection module separately and check the shared analog reference.
Key Functions

Selectable voltage ranges

Supports ±10 V, 0–10 V, ±5 V and 1–5 V input ranges across four analog inputs.

Measurement filtering

Configurable smoothing uses none, low, medium or high settings corresponding to 1, 4, 16 or 64 measurement cycles.

Channel diagnostics

Diagnostic alarms can be parameterized, with wire-break and short-circuit detection available in the 1–5 V range and a limit interrupt configurable for channel 0.

Official Specifications
Analog inputs 4 voltage inputs
Rated supply 24 V DC
Input voltage ranges ±10 V; 0–10 V; ±5 V; 1–5 V
Typical supply / backplane current 40 mA from 1L+; 12 mA from the 3.3 V backplane
Typical power loss 1.1 W
Address allocation 8 bytes
Sensor supply 4 outputs; maximum output current 1 A up to 55 °C
Measurement method Integrating
Resolution 15 bits plus sign for ±10 V and ±5 V; 15 bits for 0–10 V and 1–5 V
Integration settings 60, 20, 16.7 or 0.3 ms
Conversion time per channel 60.8, 20.8, 17.5 or 1.1 ms according to integration setting
Smoothing factors 1, 4, 16 or 64 measurement cycles
Operational voltage error ±0.1% of input range over the overall temperature range
Basic voltage error at 25 °C ±0.075% of input range
Linearity error ±0.0075% of input range
Maximum shielded signal cable 30 m
Diagnostics / limit interrupt Parameterized diagnostic alarm; limit-value interrupt configurable for channel 0
Channel isolation No isolation between inputs; isolated from backplane bus
Dimensions (W × H × D) 45 × 130 × 35 mm
Approximate weight 150 g
Frequently Asked Questions

Can 6ES7144-4FF01-0AB0 measure a 4–20 mA signal directly?

The specified measurement ranges are voltage ranges, so select a current-input module when direct current measurement is required.

Which unipolar ranges can be configured on 6ES7144-4FF01-0AB0?

The module supports 0–10 V and 1–5 V in addition to the bipolar ±10 V and ±5 V ranges.

Is the IO connection module included with 6ES7144-4FF01-0AB0?

The bus module is included, while the matching IO connection module must be ordered separately.

When can 6ES7144-4FF01-0AB0 report wire breaks and short circuits?

These diagnostics are available when the input is configured for the 1–5 V range.

Can every channel on 6ES7144-4FF01-0AB0 generate a limit-value interrupt?

The parameterizable limit-value hardware interrupt is specified for channel 0.

How does the high smoothing setting affect 6ES7144-4FF01-0AB0?

The high setting smooths measured values over 64 measurement cycles.

Are the analog channels of 6ES7144-4FF01-0AB0 isolated from one another?

The input channels are not mutually isolated, although they are isolated from the backplane bus.

Compatibility & Ordering Notes
Before ordering 6ES7144-4FF01-0AB0: Select the required voltage range and integration setting, order the matching 6ES7194-4..00-0AA0 IO connection module separately and check the shared analog reference.

Before installation

  • Order the required 6ES7194-4..00-0AA0 IO connection module separately.
  • Use shielded analog signal cables no longer than 30 m.
  • Match the input range, integration time and smoothing to the measurement task.
  • Check the shared analog reference and enable only the diagnostics supported by the selected range.
Hot Selling Models
L-PMPC604-20-32/4 32.1100.215-00
L-PMPC604-13-16 TPM-MPC-604/133-16MB
LV100
3RT1026-1BB44 3RH1921-1HA22-3AA1 3RU1126-4BB0
1552052
ST2.5/1P 3040012
FLT 60-400 2748603
MXS-BT12
ADNGF-20-60-PPS-A
ZPE10S 1739570000
DZF3280APA
0-901-94-716-7
5SX2 204-7
GV2-M10
5SY61 MCB C10 5SY6110-7

Get a Free Quote

Our representative will contact you soon.
Email
Name
Company Name
Message
0/1000
email goToTop

Evolo Automation is not an authorized distributor unless otherwise specified, representative, or affiliate of the manufacturer of this product. All trademarks and documents are the property of their respective owners and are provided for identification and informational.