Place of Origin: |
Sweden |
Brand Name: |
ABB |
Model Number: |
IMSET01 |
Packaging Details: |
Original new Factory Sealed |
Delivery Time: |
5-7 days |
Payment Terms: |
T/T |
Supply Ability: |
In stock |
Specifications
|
Parameter |
Value |
|
Model |
IMSET01 |
|
Description |
Sequence of Events Timing Module |
|
Dimension |
3.7x31.2x17.6 cm |
|
Weight |
0.38 kg |
|
Mounting |
Occupies one slot in standard module mounting unit |
|
Operating Temperature |
0° to 70°C (32° to 158°F) |
|
Relative Humidity |
5% to 95% up to 55°C; 5% to 45% at 70°C (non-condensing) |
|
Pollution Degree |
1 |
|
Altitude |
Sea level to 3 km (1.86 mi) |
|
Air Quality |
Noncorrosive |
|
CE Mark |
Compliant when installed in Symphony cabinet; EMC96 Directive 89/336/EEC; EN50082-2 Industrial Generic Immunity; EN50081-2 Industrial Generic Emission |
|
Power Supply |
+5 VDC, ±5% at 350 mA typical |
|
Microprocessor |
16-bit running at 10 MHz |
|
Memory |
64 kB RAM; 64 kB ROM |
|
Communication |
RS-485 time synchronization |
|
Digital Inputs |
Voltage: 24 VDC, 48 VDC, 125 VDC, 120 VAC; Current (typical): 5 mA (24 VDC), 4 mA (48 VDC), 4 mA (125 VDC), 5 mA (120 VAC) |
|
Turn-On Voltage (min) |
21.6 VDC, 43.2 VDC, 112.5 VDC, 108 VAC |
|
Turn-Off Voltage (max) |
10 VDC, 20 VDC, 50 VDC, 50 VAC |
|
Maximum Input Current at Min Turn-On |
4 mA (21.6 VDC), 4.4 mA (43.2 VDC), 3.2 mA (112.5 VDC), 4 mA (108 VAC) |
|
Maximum Off-Leakage Current |
1.5 mA |
|
Response Time (typical) |
DC fast: 1.1 ms; DC slow: 18 ms; AC: 5 ms after first positive half cycle |
|
Isolation |
1,000 VDC/VRMS channel to system; 350 VDC/VRMS channel to channel |
|
Surge Protection |
Meets IEEE-472-1974 surge withstand capability |
Description
The IMSET01 Sequence of Events Timing module processes up to 16 digital field inputs, and receives and decodes the time synchronization link information sent by the INTKM01 module for a Harmony controller. The controller utilizes function code 241 (DSOE data interface) to interface SOE data from the IMSET01 module to the INSEM01 module, and function code 242 (SOE digital event interface) to configure and access the IMSET01 module input channels. Each channel is optically isolated, and can be individually programmed for 24 VDC, 48 VDC, 125 VDC, and 120 VAC input.
The module communicates with its Harmony controller over I/O expander bus. Only one IMSET01 module can operate on an I/O expander bus segment. The module cable connects to NTST01 and NTDI01 termination units.
Applications
Large Power Generation: Incident Recall (SER): In the event of a boiler trip (MFT), turbine trip, or generator failure, IMSET01 ensures that hundreds of switching actions (such as relay closing and valve closing) have perfectly synchronized timestamps, helping engineers determine the "first alarm" (the source of the initial fault).
Substation Automation: Monitors the timing of high-voltage circuit breaker and protective relay actions to ensure grid safety.
Oil & Gas Plants: Emergency Shutdown Systems (ESD): In refineries or natural gas pressurization stations, records the action sequence of sensors such as pressure switches and fire detectors when emergency shutdown logic is triggered, for later safety compliance reviews.
Large Metals & Mining Plants: In high-speed rolling mills, monitors complex mechanical interlocks and hydraulic protection actions to prevent equipment damage due to millisecond-level logic delays.
Chemical Plants: Monitors the interlocking logic of critical reactors, providing precise data link analysis in emergency situations such as runaway chemical reactions.
Benefits
Enhanced System Analysis: Detailed event data with timestamps help identify bottlenecks, optimize process flow, and improve overall system performance.
Improved Troubleshooting: Precisely recorded events accelerate root cause analysis, minimizing downtime and resolving issues more efficiently.
FAQ
Q: What is the IMSET01?
A: It is a Sequence of Events Timing module.
Q: What about your delivery time of IMSET01?
A: Generally 1-3 days after receiving your payment. The specific delivery time depends on the type and quantity of the order.
Q: How long is the warranty period of IMSET01?
A: We offer a standard one-year warranty for all new and original products.
Q: Do you offer any discounts?
A: Yes! For discounts on IMSET01, please contact John for the best offer.