Overview
Place of Origin: |
USA |
Brand Name: |
GE |
Model Number: |
IC660BBD025 |
Packaging Details: |
Original new Factory Sealed |
Delivery Time: |
5-7 days |
Payment Terms: |
T/T |
Supply Ability: |
In stock |
Specifications
|
Product Name: |
Source/Sink I/O Block |
|
Model Number: |
IC660BBD025 |
|
Dimensions: |
9 x 11 x 22.5 cm |
|
Weight: |
1.44 kg |
|
LED Indicators (Block): |
Unit OK, I/O Enabled |
|
LED Indicators (Circuit): |
Individual logic side indicators |
|
Block-to-Block Isolation: |
850 V |
|
Heat Dissipation: |
11 W minimum (8 inputs), 18 W maximum (32 outputs at 0.5 A) |
|
Operating Voltage: |
10–30 VDC (12/24 V supply), 4.9–5.3 VDC (5 V supply, sink only) |
|
Maximum Ripple: |
10% (12/24 V), 1% (5 V) |
|
Required DC Power: |
150 mA typical / 300 mA maximum |
|
Power Supply Dropout Time: |
4 ms (12 V), 20 ms (24 V) |
|
Input Impedance (Typical): |
3.3 kΩ |
|
Input Processing Time (Typical): |
1.4 ms (plus selectable filter delay) |
|
Selectable Input Filter Times: |
1, 2, 3, 4, 5, 10, 20, 30, 40, 50, 60, 70, 80, 90, 100 ms |
|
Maximum Output Current (Steady State): |
0.5 A per circuit |
|
Maximum Inrush Current: |
4 A up to 10 ms (once every 0.5 sec max) |
|
Block Output Current (Total): |
16 A |
|
Output OFF Leakage Current: |
10 µA max |
|
Output Turn-On Delay: |
0.5 ms max |
|
Output Voltage Drop: |
2.0 V max at 4 A inrush |
|
Output Diagnostics: |
Switch Fault |
|
Operating Temperature: |
0 to +60 °C (32 to 140 °F) |
|
Storage Temperature: |
-40 to +100 °C (-40 to 212 °F) |
|
Humidity: |
5%–95% Non-Condensing |
|
Vibration: |
5–10 Hz 0.2” displacement, 10–200 Hz at 1G |
Description
A DC 32-Circuit Source/Sink I/O Block IC660BBD025 is an intelligent, configurable module that interfaces the controller to devices that provide or accept a binary signal. The blocks are compatible with a wide range of input devices, including both 2-wire and 3-wire electronic proximity switches. Outputs may be low-power control and indicating devices such as relays, contactors, and lamps.
Applications
Coal Power Plants: Remote I/O stations distributed throughout coal conveying and ash removal systems.
Water Treatment Plants: Monitoring the status of widely distributed valves and the start/stop of pumps.
Petrochemical Industry: Utilizing its high-voltage adaptability to address signal attenuation issues in long-distance cabling.
Mounting
Genius I/O blocks are considered "open equipment" and therefore must be installed within a protective enclosure. They should be located in an area that is clean and free of airborne contaminants. There should be adequate cooling airflow. The block can be mounted right side up, or upside down. Leave at least 2 inches of space between blocks. Mount the block by drilling two screw or bolt holes for 8-32 hardware. Position the block so that the notches in the upper and lower flanges line up with the mounting holes. Mount the block using 8-32 screws. Use star washers to provide ground integrity.
Features
Source and Sink versions each operate at nominal 12 to 24 volts DC
Sink version is also +5 volt TTL-compatible
Thirty-two configurable I/O circuits, inputs and outputs can be mixed on block
Resettable self-protecting circuits
Software configurable
Advanced diagnostics
Diagnostics
The block monitors outputs for overload conditions, and checks the actual state of the switch against the commanded state. In case of overload or wrong switch state, the block reports: FAILED SWITCH. 1 Short Circuit/Overcurrent Protection: diagnostics protect individual output circuits against excess current. For Source blocks, the load usually gets short-circuited to the DC- side of the supply. For Sink blocks, the load usually gets short-circuited to the DC+ side. If the output is commanded to go on and current exceeds 5 Amps for 1 ms, the circuit is automatically turned off and the FAILED SWITCH message issued. The circuit must be reset by cycling power to the block, or by sending a CLEAR FAULTS command from the Hand-held Monitor or the Bus Controller.
2 Surge Currents: Both Source and Sink blocks handle steady-state loads of 0.5 Amps during normal operation. Surge current protection determines conditions for safely switching loads between 0.5 Amps and 4 Amps. The following chart shows allowable surge transients.
FAQ
Q: A: Does the IC660BBD025 come with a warranty?
A: Yes, the IC660BBD025 includes a 1-year warranty.
Q: A: Does the IC660BBD025 support Genius I/O Protocol?
A: Yes, the IC660BBD025 and other Genius I/O blocks support the Genius protocol.
Q: A: What is the input voltage accepted by the IC660BBD025?
A: The IC660BBD025 accepts 5, 12, or 24 VDC input voltages.
Q: A: What is the maximum communication distance supported by the IC660BBD025?
A: The maximum communication distance is 7500 feet.