Overview
SIEMENS COMBIMASTER and MICROMASTER Integrated

6SE3290-0XX87-8BF0 OPm2 Clear Text Operator Display

A multilingual clear-text panel with an illuminated LCD, context-sensitive help, storage for ten parameter sets and USS master operation for up to 31 inverters.

At a Glance

Brand Siemens
Model 6SE3290-0XX87-8BF0
Product Type OPm2 operator display
Core Function Controls and parameterizes the inverter
Application Compatible COMBIMASTER and MICROMASTER Integrated drives

Parameter-set storage

Ten complete sets can be held in nonvolatile panel memory.

USS master access

One panel can serve up to 31 networked inverters.

PC connection

An isolated RS232 interface provides the PC link with an external supply.

Product Overview

6SE3290-0XX87-8BF0 provides the OPm2 clear-text operating interface for compatible COMBIMASTER and MICROMASTER Integrated equipment.

The menu-driven LCD combines direct motor controls, drive-state information and parameter help with upload/download functions for stored parameter sets.

Ordering focus: Match the supported drive and interface cable, keep the panel-to-drive cable within its limit, and provide the separate supply required for RS232 operation.
Key Functions

Commission and operate the inverter in clear text

The illuminated LCD offers seven languages, adjustable contrast and context-sensitive help for parameters and fault diagnosis.

Transfer complete parameter sets

Up to ten sets can be stored in nonvolatile memory and transferred between the operator panel and a drive.

Use local, master or PC access

The panel supports local control, a USS master arrangement for multiple drives and an isolated RS232 link for a PC.

Official Specifications
Display Construction Illuminated high-resolution LCD with adjustable contrast
Interface Languages 7
Nonvolatile Parameter-Set Capacity 10 sets
Maximum USS Master Network 31 inverters
PC Interface Isolated RS232
Current Drain at 5 V 250 mA
Degree of Protection IP54
Maximum Panel Cable Length 5 m
External RS232 Supply Voltage 6 V ±0.5 V
External Supply Current for RS232 50 mA maximum when connected to the drive; 250 mA when not connected
External Supply Plug Dimensions 3.5 mm outside diameter; 1.35 mm inside diameter
RS232 Connector Signals External TxD, RxD, RTS and isolated 0 V; terminal 1 not connected
Overall Dimensions 73 × 130 × 40 mm (W × H × D)
Frequently Asked Questions

How many parameter backups can I keep inside 6SE3290-0XX87-8BF0?

The panel can store up to ten parameter sets in nonvolatile memory.

Can one 6SE3290-0XX87-8BF0 access several inverters on a USS network?

The panel can operate as the central device for up to 31 networked inverters.

How long can the cable between 6SE3290-0XX87-8BF0 and the drive be?

The maximum specified panel cable length is 5 m.

Does the RS232 connection on 6SE3290-0XX87-8BF0 work without an external supply?

RS232 operation requires an external 6 V supply within a tolerance of ±0.5 V.

What supply current should I allow when 6SE3290-0XX87-8BF0 is used without a connected drive?

Allow up to 250 mA from the external supply when the panel is not connected to a drive.

How can I access the help screen on 6SE3290-0XX87-8BF0?

Hold the Menu button and press the down-arrow button to display the help screen.

What happens if I hold the Jog button on 6SE3290-0XX87-8BF0 while the motor is stopped?

The motor runs at the preset jog frequency while the button is held and stops when it is released, provided the relevant drive parameters enable the function.

Compatibility & Ordering Notes
Before ordering 6SE3290-0XX87-8BF0: Choose the OPm2 panel and the drive-specific connection cable, and include the correct external supply when the RS232 interface will be used.

Compatibility Checklist for 6SE3290-0XX87-8BF0

  • Match the drive to the COMBIMASTER or MICROMASTER Integrated OPm2 connection arrangement.
  • Select the appropriate cable, including the listed 3 m 6SE9996-0XA31 option where applicable.
  • Keep the panel-to-drive connection within 5 m.
  • Use the specified 6 V external supply and plug dimensions for RS232 operation.
  • Choose local or USS master operation to suit the drive network.
  • Retain the appropriate drive enable parameters for Run, Jog and direction functions.
Hot Selling Models
EM-10 XTMC9A10
99.02.9.220.99
EBE 253
Allen-Bradley 194R-60-NN
15/16 B3-1747
99.02.9.060.99
MSU-K016
3RT1017-1AP01
IG5496
EQ96-X 1200023010C
Allen-Bradley 100-C16D*01
5/16-REV
NHI11-PKZO
IG-3008LBPOG
OP-88002

Get a Free Quote

Our representative will contact you soon.
Email
Name
Company Name
Message
0/1000
email goToTop

Evolo Automation is not an authorized distributor unless otherwise specified, representative, or affiliate of the manufacturer of this product. All trademarks and documents are the property of their respective owners and are provided for identification and informational.