IC200ALG260G VersaMax Eight-Channel Analog Input Module

An eight-channel single-ended input module with 12-bit conversion, carrier-jumper range selection and backplane-powered electronics.

At a Glance

Brand GE Fanuc
Model IC200ALG260G
Product Type Analog input module
Core Function Acquiring voltage or current measurements
Application VersaMax CPU and network-interface I/O stations

Hardware-selected signal ranges

Carrier jumpers select current operation or bipolar and unipolar voltage operation.

Eight-word data interface

The module supplies eight words of analog input data to the CPU or network interface.

Separate power indicators

INT PWR and OK indicators distinguish internal field-circuit power from backplane power.

Product Overview

IC200ALG260G acquires eight analog field signals through the VersaMax I/O system.

All inputs share a common return, while optical isolation separates the field-input group from logic and frame ground; external power remains necessary for the connected transmitters.

Ordering focus: Match the carrier wiring, selected voltage/current range, shared return and external transmitter supply.
Key Functions

Hardware-selected signal ranges

Carrier jumpers select current operation or bipolar and unipolar voltage operation.

Eight-word data interface

The module supplies eight words of analog input data to the CPU or network interface.

Separate power indicators

INT PWR and OK indicators distinguish internal field-circuit power from backplane power.

Official Specifications
Input arrangement 8 single-ended channels in one group
Signal ranges ±10 V DC default; configurable 0–10 V DC or 4–20 mA
Conversion resolution 12 bits; 2.5 mV or 4 µA increments correspond to 8 reported counts
Input-to-logic and frame isolation 250 V AC continuous; 1,500 V AC for 1 minute
Channel isolation No channel-to-channel isolation; common return
Maximum backplane load 130 mA from 5 V
Module power source Backplane; no separate module power supply
Voltage-input impedance 126 kΩ maximum
Current-input impedance 200 Ω maximum
Accuracy at 25 °C ±0.3% of full scale typical; ±0.5% maximum
Accuracy over 0–60 °C ±1% of full scale maximum; may degrade to ±3% under severe 10 V/m RF interference
Input-filter response 5 ms
Module update rate 0.4 ms
Minimum channel crosstalk rejection 30 dB
Data allocation 8 analog-input words
Module diagnostic Loss of Internal Power for field-side circuits
Frequently Asked Questions

Do the input channels of IC200ALG260G have individual isolation?

The inputs share a common return and are not isolated from one another.

How do I select voltage or current operation on IC200ALG260G?

Use the two jumpers on the carrier terminals to select the operating mode and voltage range.

Which range does IC200ALG260G use when no selection jumper is fitted?

With no jumper installed, the module accepts bipolar −10 to +10 V DC signals.

Can IC200ALG260G supply power to the field transmitters?

An external source must provide power for the field transmitters.

Can I connect both voltage and current devices to the same channel on IC200ALG260G?

Connect either a voltage device or a current device to a channel, rather than both.

Does the 0.4 ms update rate of IC200ALG260G remove the input-filter delay?

The module has a specified 5 ms input-filter response in addition to its 0.4 ms update rate.

What do the two green power indicators on IC200ALG260G mean?

INT PWR indicates internal field-circuit power and OK indicates backplane power.

Compatibility & Ordering Notes
Before ordering IC200ALG260G: Match the carrier wiring, selected voltage/current range, shared return and external transmitter supply.

Before installation

  • Select a carrier with the appropriate terminal arrangement and jumper connections.
  • Set the range and operating mode to match the connected field devices.
  • Provide external transmitter power and maintain the common-return arrangement.
  • Ground cable shields using the suitable carrier or interposing terminal arrangement.
Hot Selling Models
BES02WK M12MC1-PSC10F-S04G
FMS12-165
NRN10-12GM40-E2-C-V1
RH1B-U
VT12T-2P430 6026216
BES02WH M12EG1-PSC60Z-S04G-S11
WA-1-B
0330 R025
5S-1449/25/46 418162
IFFM12P17A3/S05L
GL6-P3211
2-8-10 ZSTPKG-1641-1
BES02WK BES M12MC1-PSC10F-S04G
FMS12-165 517-51418
6ES7132-6BF00-0AA0

Get a Free Quote

Our representative will contact you soon.
Email
Name
Company Name
Message
0/1000
email goToTop

Evolo Automation is not an authorized distributor unless otherwise specified, representative, or affiliate of the manufacturer of this product. All trademarks and documents are the property of their respective owners and are provided for identification and informational.