Get a Free Quote

Our representative will contact you soon.
Email
Name
Company Name
Message
0/1000
eaton mtl831b mtl831b sixteen channel analog transmitter-0

Others

Home >  Products >  Others

Eaton MTL831B Sixteen-Channel Analog Transmitter MTL831B

Manufacturer: Eaton
Condition: Brand New
Lead Time: In Stock
Origin: United Kingdom
Warranty: 12 Months

  • Overview
  • Product Overview
  • Key Functions
  • Official Specifications
  • Frequently Asked Questions
  • Compatibility & Ordering Notes
  • Hot Selling Models
  • Recommended Products
Overview

Eaton • MTL830B Temperature Multiplexer

MTL831B MTL831B Sixteen-Channel Analog Transmitter

The MTL831B is a sixteen-channel field transmitter for thermocouple, RTD and millivolt signals in the MTL830B temperature multiplexer system, with two selectable addresses and dual data highways.

At a Glance

Brand MTL
Model MTL831B
Product Type Hazardous-area analog multiplexer transmitter
Core Function Collects distributed temperature and millivolt measurements for multiplexed transmission
Application or Compatible Series Hazardous-area temperature monitoring in MTL830B systems

Exact Identification

Match MTL831B character by character and confirm the complete MTL831B Sixteen-Channel Analog Transmitter designation.

Interface Arrangement

Confirm the installed supply, ports, field connections and required accessories before wiring the replacement.

Configuration Check

Preserve the approved engineering project, network parameters and application data used by the installed system.

Product Overview

The MTL831B is a sixteen-channel field transmitter for thermocouple, RTD and millivolt signals in the MTL830B temperature multiplexer system, with two selectable addresses and dual data highways.

One transmitter accepts a mix of supported thermocouple, RTD and millivolt inputs according to its configuration. Two highways provide the documented field-to-receiver transmission path and status monitoring arrangement. Hazardous-area applications use an MTL3052 isolating interface on each data highway.

Ordering focus: confirm the MTL830B system generation, sixteen channel configurations, SW100 address, both data highways, MTL3052 isolators, MTL838B receiver and hazardous-area approvals.
Key Functions

Sixteen Sensor Channels

One transmitter accepts a mix of supported thermocouple, RTD and millivolt inputs according to its configuration.

Dual Data Highways

Two highways provide the documented field-to-receiver transmission path and status monitoring arrangement.

Intrinsically Safe System Architecture

Hazardous-area applications use an MTL3052 isolating interface on each data highway.

Official Specifications
Sensor Inputs 16
Supported Input Types Thermocouple, millivolt and RTD
Selectable Addresses 1 or 2 using SW100 switches
Data Highways 2
Maximum Highway Impedance with MTL3052 Terminals 7 and 8 50 Ω
Maximum Highway Impedance with MTL3052 Terminals 5 and 6 130 Ω
Maximum Highway Impedance for Non-IS Use 300 Ω
Typical IS Transmission Distance 0.5 km
Typical Non-IS Transmission Distance 1.5 km
IS Interface Requirement One MTL3052 isolator per data highway
Humidity Range 5 to 95 % RH, non-condensing
Terminal Capacity Two 2.5 mm² conductors per detachable terminal
Casing Material Moulded polycarbonate
Hazardous-Area Temperature Class T4
Frequently Asked Questions

Which sensors can I connect to MTL831B?

Configure the sixteen channels for the supported thermocouple, millivolt or RTD input types.

How do I set the field address on MTL831B?

Set SW100 switches 1 and 2 for address 1 or 2 as required by the existing system.

Does MTL831B require one or two data highways?

The transmitter provides two highways, and both should be wired and checked according to the installed architecture.

Which isolator is used with MTL831B in an intrinsically safe loop?

Use one MTL3052 isolating interface for each data highway in the documented system.

How far can MTL831B normally communicate in a hazardous-area installation?

The typical intrinsically safe transmission distance is 0.5 km within the specified highway conditions.

Can I replace only MTL831B with the newer MTL831C?

No; migration requires the transmitter, isolator, receiver and configuration software to be changed as a complete system.

What should I record before removing MTL831B?

Record every channel type and wiring, both highway connections, the SW100 address and the receiver configuration.

Compatibility & Ordering Notes
Before ordering MTL831B: confirm the MTL830B system generation, sixteen channel configurations, SW100 address, both data highways, MTL3052 isolators, MTL838B receiver and hazardous-area approvals.

Compatibility Checklist

  • Keep the transmitter paired with the MTL3052 and MTL838B generation.
  • Do not mix MTL830B and MTL830C physical-layer components.
  • Verify entity parameters and installation certificates for hazardous-area circuits.
Hot Selling Models
3SB3245-0AA31-0CC0
87141012 KDL/C 24/12
CH10 A200 F74863
TM-1-8290/E
TM-1-8290 TM-1-8290/E
PKZM0-4 NHI-E-10-PKZ0
3RT1016-1KB41
6ES5375-0LC11
ZK1020-0101-0005
Allen-Bradley 1492-SP1C010
MCR-CI/I-00-DCI
CPV10-EPL-E
3SB3602-0AA11
NEBU-M8G3-K-2.5-LE3
VUVG-B14-M52-AZT-F-1T1L

Get a Free Quote

Our representative will contact you soon.
Email
Name
Company Name
Message
0/1000
email goToTop

Evolo Automation is not an authorized distributor unless otherwise specified, representative, or affiliate of the manufacturer of this product. All trademarks and documents are the property of their respective owners and are provided for identification and informational.