Overview
SIMATIC S7-400 • Local Rack Expansion

6ES7460-1BA00-0AB0 SIMATIC S7-400 IM 460-1 Local Expansion Send Module

IM 460-1 send interface with two local expansion connections, transferring the P bus and 5 V power over links up to 1.5 m per line.

At a Glance

Brand Siemens
Model 6ES7460-1BA00-0AB0
Product Type Expansion send interface module
Core Function Linking a central rack to local expansion racks
Application S7-400 expansion with transferred 5 V power

Two local expansion lines

Front connectors X1 and X2 provide separate lines, each serving one expansion rack.

Transferred rack power

Each line carries the P bus and supplies 5 V at up to 5 A to the connected expansion rack.

Link indication

Green C1/C2 LEDs indicate line state and the red EXTF LED indicates an external line fault.

Product Overview

6ES7460-1BA00-0AB0 links the S7-400 central rack to IM 461-1 receive interfaces in nearby expansion racks, transferring both the P bus and 5 V power through the expansion cable.

Each line serves one expansion rack with a 5 V, 5 A supply limit, so the rack arrangement must be planned without a separate expansion-rack power supply or communication-bus transfer.

Ordering focus: Pair the central-rack sender with IM 461-1 receivers and 6ES7468-3... cables, keep each local line within 1.5 m and check the receiver revision for termination.
Key Functions

Two local expansion lines

Front connectors X1 and X2 provide separate lines, each serving one expansion rack.

Transferred rack power

Each line carries the P bus and supplies 5 V at up to 5 A to the connected expansion rack.

Link indication

Green C1/C2 LEDs indicate line state and the red EXTF LED indicates an external line fault.

Official Specifications
Expansion connections 2 front connections, X1 and X2
Expansion racks per line 1
Maximum line length 1.5 m total per line
Power transferred to each rack 5 V DC, maximum 5 A per line
24 V power transfer Not provided
Communication-bus transfer Not provided
Backup-current transfer Not provided
Current from 5 V backplane Typically 50 mA; maximum 85 mA
Module power loss Typically 250 mW; maximum 425 mW
Connection-cable family 6ES7468-3... for P-bus and power transfer
Line indicators C1 and C2 green; EXTF red
Dimensions (W × H × D) 25 × 290 × 280 mm
Weight 600 g
Frequently Asked Questions

Can two expansion racks be connected to one line of 6ES7460-1BA00-0AB0?

Each line permits only one expansion rack, although the sender provides two separate lines.

Should a power supply be installed in the rack connected through 6ES7460-1BA00-0AB0?

A separate power supply must not be installed in an expansion rack powered through the IM 461-1 link.

Does 6ES7460-1BA00-0AB0 transfer the communication bus for CP or FM requirements?

The link transfers the P bus and 5 V power but does not transfer the communication bus.

How far can the expansion rack be placed from 6ES7460-1BA00-0AB0?

Keep the total connection length within 1.5 m on each line.

Which cable family should be selected for 6ES7460-1BA00-0AB0?

Use the 6ES7468-3 cable family intended for P-bus and power transfer with IM 460-1 and IM 461-1.

Does a receiver used with 6ES7460-1BA00-0AB0 always need an external terminator?

The older IM 461-1 1BA00 receiver uses terminator 6ES7461-1BA00-7AA0, while the 1BA01 revision integrates termination.

Can the expansion cable of 6ES7460-1BA00-0AB0 be changed with the racks energized?

Switch off the affected central and expansion-rack supplies before changing interface modules or their connecting cables.

Compatibility & Ordering Notes
Before ordering 6ES7460-1BA00-0AB0: Pair the central-rack sender with IM 461-1 receivers and 6ES7468-3... cables, keep each local line within 1.5 m and check the receiver revision for termination.

Before installation

  • Install the send interface in the central rack and the IM 461-1 receive interface in each connected expansion rack.
  • Keep each expansion line within 1.5 m and its module demand within 5 V/5 A.
  • Do not fit a separate power supply in a power-transferred expansion rack.
  • Check receiver revision, termination and unique rack numbering before restoring power.
Hot Selling Models
5SB281
CA20B CA20BNL3915VE
3RV2011-0FA20
61543000
ADN-25-50-APA
Allen Bradley 1489-A1C160
7000-17001-7221000
PKZ 2 ZM-2,4-PKZ2 + NHI-11-PKZ-2
3VA9483-0QB00
ABB TSA101
3X400VAC/16A
A17T03105
6ES7331-7KB01-0AB0
3SE2120-0GW
7000-43301-6400100

Get a Free Quote

Our representative will contact you soon.
Email
Name
Company Name
Message
0/1000
email goToTop

Evolo Automation is not an authorized distributor unless otherwise specified, representative, or affiliate of the manufacturer of this product. All trademarks and documents are the property of their respective owners and are provided for identification and informational.