Siemens 3RK1207-1BQ44-0AA3 AS-Interface K60 Four-Channel Analog Current Input Module
Manufacturer: Siemens
Condition: Brand New
Lead Time: In Stock
Origin: Germany
Warranty: 12 Months
Email: [email protected]
whatsApp: +86-18150117685
- Overview
- Hot Selling Models
- Recommended Products
Overview
- Order mounting plate 3RK1901-0CA00 separately.
- Configure the AS-i master for the analog slave profile 7.3 and the intended current range.
- Match the four-wire sensor connection to the M12 pin assignment.
- Complete the connector sealing and mounting arrangement appropriate to the IP67 field installation.
3RK1207-1BQ44-0AA3 AS-Interface K60 Four-Channel Analog Current Input Module
IP67 K60 analog slave with four M12 current inputs, 16-bit conversion and support for 4–20 mA or ±20 mA signals.
At a Glance
| Brand | Siemens |
|---|---|
| Model | 3RK1207-1BQ44-0AA3 |
| Product Type | Analog fieldbus input module |
| Core Function | Acquisition of current signals through AS-Interface |
| Application | Distributed current transmitter connections at machine level |
Four current measurement inputs
Four M12 sockets connect current transmitters for 4–20 mA or ±20 mA measurement with the appropriate sensor wiring.
AS-i analog communication
The module operates as an analog slave with profile 7.3 and 16-bit analog conversion.
Protected field installation
The IP67 K60 housing supports mounting on a standard rail or wall through the corresponding mounting plate.
Product Overview
3RK1207-1BQ44-0AA3 connects four analog current signals to an AS-Interface system through M12 field connections.
The compact IP67 module supports field installation using a K60 mounting plate, with parameterized current measurement for four-wire sensors.
Key Functions
Four current measurement inputs
Four M12 sockets connect current transmitters for 4–20 mA or ±20 mA measurement with the appropriate sensor wiring.
AS-i analog communication
The module operates as an analog slave with profile 7.3 and 16-bit analog conversion.
Protected field installation
The IP67 K60 housing supports mounting on a standard rail or wall through the corresponding mounting plate.
Official Specifications
| Analog current inputs | 4 |
|---|---|
| Measurement ranges | 4–20 mA and ±20 mA for four-wire sensors |
| Analog outputs | 0 |
| A/D resolution | 16 bits |
| AS-i slave profile | 7.3 |
| Sensor connection | 4 × M12 screw-type sockets |
| Four-wire input pin assignment | Pin 1: L+24 V; pin 2: IN+; pin 3: GND; pin 4: IN-; pin 5: FE |
| Maximum AS-i current consumption | 160 mA at 30 V |
| Degree of protection | IP67 |
| Operating temperature | -20 to +60 °C |
| Storage temperature | -40 to +85 °C |
| Dimensions (W × H × D) | 60 × 152 × 29 mm |
Frequently Asked Questions
Can 3RK1207-1BQ44-0AA3 measure negative current values?
The ±20 mA mode supports bipolar current measurement with the corresponding four-wire sensor connection.
Does 3RK1207-1BQ44-0AA3 provide an analog output for an actuator?
The module has four analog inputs and no analog outputs.
Which connector format is used for sensors on 3RK1207-1BQ44-0AA3?
The four sensor connections use M12 screw-type sockets.
What mounting accessory is required for 3RK1207-1BQ44-0AA3?
Order the 3RK1901-0CA00 mounting plate separately for the supported K60 installation arrangement.
Can 3RK1207-1BQ44-0AA3 be used at a field location exposed to -10 °C?
Its specified operating temperature range is -20 to +60 °C.
How much AS-i supply current should I budget for 3RK1207-1BQ44-0AA3?
Allow a maximum of 160 mA from the AS-Interface profile conductors at 30 V.
Which M12 pin on 3RK1207-1BQ44-0AA3 carries the positive measurement input?
Pin 2 is IN+ while pin 4 is IN- in the four-wire input assignment.