- Overview
- Specifications
- Description
- Applications
- Maintenance Recommendations
- FAQ
- Recommended Products
Overview
Place of Origin: |
Sweden |
Brand Name: |
ABB |
Model Number: |
3BHT410082R0001 |
Packaging Details: |
Original new Factory Sealed |
Delivery Time: |
5-7 days |
Payment Terms: |
T/T |
Supply Ability: |
In stock |
Specifications
|
Parameter |
Value |
|
Part Number |
3BHT410082R0001 |
|
Module Type |
Advant Bus Extender |
|
Dimensions |
40 × 35 × 7 cm |
|
Weight |
2.36 kg |
|
Operating Temperature |
0 °C to +60 °C |
|
Storage Temperature |
-20 °C to +85 °C |
|
Humidity |
5% to 95% (non-condensing) |
|
Bus Type |
Compatible with ABB standard bus protocols |
|
Data Transfer Rate |
High-speed communication supported for reliable data transfer |
Description
The ABB 3BHT410082R0001 is an Advant Bus Extender designed to enhance the connectivity and communication capabilities within ABB's industrial automation systems. This module is engineered to extend the bus communication range, ensuring reliable and efficient data transfer across extended system architectures. It is integral for systems where signal integrity and communication reliability over longer distances are critical.
Applications
Rail Transit Power Plant: Extends the control bus between extremely long platforms or substations.
Combined Cycle Power Plant: Connects the main control room cabinets to sub-cabinets distributed throughout the plant area.
Non-Ferrous Metal Refinery: Spans large production workshops, aggregating remotely acquired data to the core system.
Water Supply Network Plant: Extends communication between the dispatch center and remote pumping station racks.
Maintenance Recommendations
Cable Protection: Ensure the bus expansion cable is not excessively bent within the cable tray to prevent physical damage.
Matching Verification: When replacing expansion modules, ensure the module model and firmware version at both ends are completely consistent.
Regular Cleaning: Clean the gold fingers and cable female ends on the back of the expander to prevent oil contamination from affecting communication stability.
FAQ
Q: Will a faulty expansion module like 3BHT410082R0001 affect the main control’s operation?
A: The main controller will continue running normally, but all I/O signals from the affected expansion rack will be lost.
Q: Does the expansion rack address of 3BHT410082R0001 need to be manually set?
A: Yes. The module address is typically configured via DIP switches or backplane settings to ensure correct bus identification.
Q: Can the bus expansion cable for 3BHT410082R0001 be installed alongside power lines?
A: No. It is strictly prohibited due to electromagnetic interference. A minimum separation of about 30 cm is recommended to ensure stable communication.
Q: Why is the expansion rack of 3BHT410082R0001 still not recognized after replacing the module?
A: Check whether the bus terminator (terminal resistor plug) is correctly installed on the last module in the expansion chain.
Q: What is the maximum expansion distance supported by 3BHT410082R0001?
A: It depends on whether copper cable or fiber optic is used. The exact limit should be confirmed according to the official cabling specification manual.