- Overview
- Specifications
- Description
- Applications
- Features
- Functions
- Installation
- FAQ
- Recommended Products
Overview
Place of Origin: |
USA |
Brand Name: |
GE |
Model Number: |
IC697BEM713 |
Packaging Details: |
Original new Factory Sealed |
Delivery Time: |
5-7 days |
Payment Terms: |
T/T |
Supply Ability: |
In stock |
Specifications
|
Parameter |
Value |
|
Module Name |
IC697BEM713 Bus Transmitter Module |
|
Module Type |
Bus Transmitter Module |
|
Dimensions |
4 x 22 x 29.1 cm |
|
Weight |
0.46 kg |
|
Product Line |
Series 90-70 |
|
Voltage Input |
5 V DC |
|
Current Required from 5V Bus |
1.4 A |
|
Current Draw |
1.4 A |
|
Compatibility |
IC697 PLC |
|
Module Location |
Any slot except Slot 1 |
|
Programmer Interface |
1 |
|
Programmer Interface Specification |
Effective data rate 500 Kbytes/sec; Time to store 16 Kbyte program: 20–30 sec |
|
Expansion Interface |
1 |
|
Expansion Interface Specification |
Electrical isolation: non-isolated differential communications; VME system supports VME standard C.1 |
|
Maximum Cable Length |
50 feet (15 meters) |
|
Status LEDs |
OK, PGMR, Last Rack |
|
Interfaces |
One (1) Parallel port; One (1) Expansion port |
Description
The Series 90-70 module with catalog number IC697BEM713 is a Bus Transmitter module. This module is used to the local bus where the Centra Processing Unit (CPU) is installed, allowing additional I/O and option modules to be installed to the system. This bus transmitter module is capable of handling up to Seven (7) Bus receiver Modules with catalog number IC697BEM711. When implementing Local Bus expansion, the maximum distance from the IC697BEM713 Bus Transmitter Module (BEM) to the last IC697BEM711 Bus Receiver Module (BRM) must not exceed 50 ft. Additionally, the last BRM must be installed with a terminating resistor with catalog number IC697ACC702, to close the daisy-chain network. This terminating resistor is attached to the Expansion Port Out of the last BRM. The IC697BEM713 comes with One (1) Parallel Port used for programming and configuration functions and One (1) Expansion port that connects to the 1st BRM of the network. The appropriate programming software to configure settings and download configuration to the IC697BEM713 are the MS-DOS or Windows programming software configuration function. The IC697BEM713 occupies a single slot of the chassis, specifically, installed to the to any slot except slot 1 which is reserved for the Series 90-30 CPU. This module has a current draw of 1.4 A, effective data rate of 500 Kbytes / sec and duration to store 16Kbyte program is 20-30 Seconds. This module is designed in compatibility with ME standard C.1.
Applications
Steel/Metallurgical Plants: Controlling rolling mill lines hundreds of meters long. Analysis: High temperature resistance, interference resistance, connecting distributed remote I/O.
Power Plants/Substations: Used for auxiliary control of boilers and steam turbines. Analysis: Low-level bus cascading, extremely fast transmission, meeting real-time protection requirements.
Oil/Chemical Plants: Managing long-distance connections between the central control room and tank farms. Analysis: Reduces wiring costs and supports centralized monitoring of secure areas.
Features
High Performance Parallel Programmer Interface
Bus Expansion Interface
Supports up to 7 Expansion racks
Three LED indicators provide module, programmer port, and expansion port status
No DIP switches to set, easy software configuration into PLC system
Functions
The Bus Transmitter Module (BTM) permits expansion from the main CPU rack when more modules are required in a system than can be contained in the CPU rack. The BTM allows expansion from the CPU rack to a maximum of 7 additional IC697 PLC racks. It also provides a high performance parallel interface to the programming device.
The module occupies a single slot and has two connectors. The top one is for attachment to the programming device. The bottom one is for a daisychained arrangement through Bus Receiver Modules to expansion racks.
Three green LEDs provide status indication of each port and module status.
The BTM must be configured into the IC697 PLC system using the MS-DOS or Windows programming software configuration function.
Installation
Installation should not be attempted without referring to the applicable Programmer Controller Installation Manual.
Make sure rack power is off.
Install in any slot (except slot 1) in the main CPU rack.
Turn on power
FAQ
Q: Does the IC697BEM713 come with a warranty?
A: Yes, the IC697BEM713 includes a 1-year warranty.
Q: How many expansion ports does the IC697BEM713 have?
A: The IC697BEM713 has one (1) expansion port.
Q: What is the function of the module’s parallel port?
A: The parallel port is used for programming the module.
Q: How many slots does the IC697BEM713 occupy in the chassis?
A: The IC697BEM713 occupies a single slot of the chassis.