Siemens SIMATIC S7-1200 3RK7243-2AA30-0XB0 CM 1243-2 AS-Interface Master

Manufacturer: Siemens
Condition: Brand New
Lead Time: In Stock
Origin: Czech Republic
Warranty: 12 Months

  • Overview
  • Hot Selling Models
  • Recommended Products
Overview

Siemens · SIMATIC S7-1200 CM 1243-2

3RK7243-2AA30-0XB0 CM 1243-2 AS-Interface Master Communication Module

Siemens 3RK7243-2AA30-0XB0 is the SIMATIC S7-1200 CM 1243-2 AS-Interface master communication module to AS-i specification V3.0. It exchanges digital and analog process data with the CPU through the backplane bus and is configured in STEP 7 or through the command interface.

At a Glance

Brand Siemens
Model 3RK7243-2AA30-0XB0
Product Type AS-Interface Master Communication Module
Core Function Connects AS-i field devices to a compact controller
Application or Compatible Series SIMATIC S7-1200 distributed sensor and actuator networks

AS-i Segment Design

Count standard and A/B-addressed slaves, calculate the bus cycle and confirm the required process-image capacity.

Controller Capacity

Include the module in the S7-1200 limit of three communication modules or processors in total.

Power Arrangement

Decide whether the segment uses a conventional AS-i supply or AS-i Power24V and verify current and decoupling requirements.

Product Overview

Siemens 3RK7243-2AA30-0XB0 is the SIMATIC S7-1200 CM 1243-2 AS-Interface master communication module to AS-i specification V3.0. It exchanges digital and analog process data with the CPU through the backplane bus and is configured in STEP 7 or through the command interface.

Adds one M4-profile AS-Interface master to a compact controller station. Maps field I/O through process-image or peripheral addresses and supports record transfer for additional data. Uses dedicated AS-i, PF, CM, CER and DIAG indicators for commissioning and fault localization.

Ordering focus: Confirm the complete 3RK7243-2AA30-0XB0 article, S7-1200 CPU capacity, AS-i V3.0 slave inventory, standard or A/B addressing, segment power concept and STEP 7 project before ordering..

Key Functions

AS-i Master Integration

Adds one M4-profile AS-Interface master to a compact controller station.

Digital and Analog Data Access

Maps field I/O through process-image or peripheral addresses and supports record transfer for additional data.

Local Status Diagnostics

Uses dedicated AS-i, PF, CM, CER and DIAG indicators for commissioning and fault localization.

Official Specifications

AS-Interface Specification V3.0
Master Profile M4
AS-i Interfaces 1
Maximum AS-i Transfer Rate 167,000 bit/s
Electrical Connection Removable screw terminals
Voltage Supply Via the S7-1200 backplane bus
Maximum AS-i Profile-Conductor Current 100 mA at 30 V
Maximum Backplane Current 250 mA
Power Loss 2.9 W
Rated Insulation Voltage 500 V
Galvanic Isolation Provided between the AS-i side and controller electronics
Degree of Protection IP20
Status Indicators AS-i, PF, CM, CER and DIAG LEDs
Maximum Modules per CPU 3 communication modules or processors in total
CPU Data-Exchange Cycle 10 ms
AS-i Cycle at 31 Slave Addresses Up to 5 ms
AS-i Cycle at 62 A/B Addresses Up to 10 ms
Maximum Digital Capacity 496 DI and 496 DQ per communication module
Analog Slave Capacity 31 standard-address slaves with up to 4 channels each, or 62 A/B-addressed slaves with up to 2 channels each
Mechanical Format 30 x 100 x 75 mm; snap-on mounting to a 35 mm symmetrical DIN rail

Frequently Asked Questions

How many AS-i slaves can 3RK7243-2AA30-0XB0 serve?

The segment can use up to 31 standard-address analog slaves or 62 A/B-addressed analog slaves within the stated channel and cycle limits.

How is 3RK7243-2AA30-0XB0 configured?

Configure the master in STEP 7 or use the command interface and then match the projected slave list to the installed segment.

Can 3RK7243-2AA30-0XB0 use AS-i Power24V?

Yes, all product versions support that topology when the power, data-decoupling and cable rules are met.

What is the communication cycle for 3RK7243-2AA30-0XB0?

Allow 10 ms for exchange with the CPU plus an AS-i cycle of up to 5 ms for 31 addresses or 10 ms for 62 A/B addresses.

Does 3RK7243-2AA30-0XB0 support ASIsafe directly?

No, the listed master does not provide the ASIsafe protocol function.

How many communication modules can share a CPU with 3RK7243-2AA30-0XB0?

The controller accepts a maximum total of three communication modules or processors, including this master.

What should I verify before replacing 3RK7243-2AA30-0XB0?

Record the slave addresses, I/O mapping, power concept, cycle requirements, terminal wiring and STEP 7 configuration before exchange.

Compatibility & Ordering Notes

Before ordering 3RK7243-2AA30-0XB0: Confirm the complete 3RK7243-2AA30-0XB0 article, S7-1200 CPU capacity, AS-i V3.0 slave inventory, standard or A/B addressing, segment power concept and STEP 7 project before ordering..

Compatibility Checklist

  • Confirm a SIMATIC S7-1200 CPU with capacity for another communication module.
  • Keep the station within the three-module total limit for communication modules and processors.
  • Match every AS-i slave address, profile and standard or A/B addressing mode.
  • Verify the AS-i supply, Power24V design and any required DCM 1271 data decoupling.
  • Restore process-image, peripheral-address and record-transfer assignments.
  • Check screw-terminal wiring, cable polarity, shield practice and segment current demand.
  • Confirm the required bus and CPU exchange cycle against the application timing.
Hot Selling Models
1.30.242.262/2200
3RV1011-0HA10 3RT1015-1BB41 3RT1015-1BB41
3RH1140-2BB40
V11-G-BK5M-PUR-U-V3-GM
3RV1011-1KA10 3RV1901-1D
NBN30-L2-B3B-V1
7000-12421-6340200
051431000000
3SU1051-0AB20-0AA0
5.08HC/05/180
2-31/UKH 0201388
3RV1011-1AA10
2CDS252001R0104
TCL24-124DC
3RV1021-1EA10

Get a Free Quote

Our representative will contact you soon.
Email
Name
Company Name
Message
0/1000
email goToTop

Evolo Automation is not an authorized distributor unless otherwise specified, representative, or affiliate of the manufacturer of this product. All trademarks and documents are the property of their respective owners and are provided for identification and informational.