Siemens SIMATIC NET 6GK1562-2AA00 CP 5622 PCI Express PROFIBUS Communication Processor
Manufacturer: Siemens
Condition: Brand New
Lead Time: In Stock
Origin: Germany
Warranty: 12 Months
Email: [email protected]
whatsApp: +86-18150117685
- Overview
- Hot Selling Models
- Recommended Products
Overview
- Confirm an available PCI Express x1, x4, x8 or x16 slot with sufficient internal clearance.
- Match the nine-pin Sub-D cabling, RS485 termination and required network transmission rate.
- Verify the SIMATIC NET or SOFTNET release and its approved operating system before installation.
- Preserve the saved PC-station configuration, PROFIBUS or MPI address and existing bus profile.
- Limit one physical segment to 32 devices and use repeaters when extending the network toward 64 nodes.
- Allow for the specified 3.3 V and 12 V host-bus current requirements.
Siemens · SIMATIC NET CP 5622
6GK1562-2AA00 PCI Express PROFIBUS Communication Processor
Siemens 6GK1562-2AA00 is a SIMATIC NET CP 5622 communication processor that connects a programming device, PC or industrial PC to a PROFIBUS or MPI network through a PCI Express x1 host interface.
At a Glance
| Brand | Siemens |
|---|---|
| Model | 6GK1562-2AA00 |
| Product Type | PCI Express PROFIBUS/MPI Communication Processor |
| Core Function | Connects a compatible computer to PROFIBUS or MPI networks |
| Application or Compatible Series | SIMATIC NET PG, PC and industrial PC installations |
Exact Identification
Match the complete CP 5622 article number because CP 5623 and CP 5624 use different hardware and dimensional data.
Host Interface Match
Install the short-format PCI Express x1 card in a compatible x1, x4, x8 or x16 slot.
Bus Connection
Use the nine-pin female Sub-D RS485 interface with the required PROFIBUS or MPI cable and termination.
Product Overview
Siemens 6GK1562-2AA00 is a SIMATIC NET CP 5622 communication processor that connects a programming device, PC or industrial PC to a PROFIBUS or MPI network through a PCI Express x1 host interface.
The network interface supports transmission rates from 9.6 kbit/s through 12 Mbit/s. Compatible SIMATIC engineering software can communicate with automation devices on an MPI network. The compact PCI Express card receives its operating power from the host computer without a separate external supply.
Key Functions
High-Speed PROFIBUS Access
The network interface supports transmission rates from 9.6 kbit/s through 12 Mbit/s.
MPI Engineering Connectivity
Compatible SIMATIC engineering software can communicate with automation devices on an MPI network.
Host-Powered PC Integration
The compact PCI Express card receives its operating power from the host computer without a separate external supply.
Official Specifications
| PROFIBUS Electrical Connections | 1 |
|---|---|
| Supported PROFIBUS Rates | 9.6, 19.2, 45.45, 93.75, 187.5 and 500 kbit/s; 1.5, 3, 6 and 12 Mbit/s |
| PROFIBUS Connector | 9-pin D-sub female connector with screw locking |
| RS485 Electrical Design | Floating interface signals within SELV limits with grounded cable shield |
| Host Bus Interface | PCI Express x1 V2.0 plug and play; usable in x4, x8 and x16 slots |
| Devices per Bus Segment | Up to 32 PCs, PGs, SIMATIC S7 or ET 200 devices |
| Maximum Nodes with Repeaters | 64 |
| Direct PLC Coupling Rate | Up to 187.5 kbit/s for the additional interface signals |
| Backplane Supply | 3.3 V DC and 12 V DC |
| Permitted Supply Ranges | 3.0 to 3.6 V DC and 11.0 to 13.0 V DC |
| Maximum Backplane Current | 0.3 A at 3.3 V DC and 0.25 A at 12 V DC |
| Power Loss | 4 W |
| Storage and Transport Temperature | −20 to +60 °C |
| Degree of Protection | IP00 |
| Dimensions and Weight | 18 × 112 × 101 mm; 87 g |
| Identical Plug-In Cards per PC | 1 |
| Operating Vibration | 0.075 mm at 10–58 Hz and 10 m/s² at 58–500 Hz; 10 cycles per axis |
| Operating Shock | 50 m/s² half-sine for 30 ms; 100 shocks per axis |
| Emission Class | Class B according to EN 55022 and FCC |
| Signal-Cable Immunity | ±2 kV surge and ±2 kV burst |
Frequently Asked Questions
Which PCI Express slot can I use for 6GK1562-2AA00?
The short card uses a PCI Express x1 interface and can also operate in x4, x8 or x16 slots.
Which fieldbus connector should I use with 6GK1562-2AA00?
The network connection uses a nine-pin female Sub-D RS485 socket.
What PROFIBUS speed range can I configure on 6GK1562-2AA00?
The selectable transmission range extends from 9.6 kbit/s through 12 Mbit/s.
Can I connect 6GK1562-2AA00 to an MPI network?
The card supports MPI access when it is used with compatible Siemens communication software.
How many devices can share one segment with 6GK1562-2AA00?
One segment can contain up to 32 PCs, programming devices, SIMATIC S7 stations or ET 200 devices.
What power must the host provide for 6GK1562-2AA00?
The PCI Express backplane must provide 3.3 V DC and 12 V DC within the stated permitted ranges.
What should I verify before selecting an operating system for 6GK1562-2AA00?
Match the 32-bit or 64-bit operating-system release to the compatibility list for the installed SIMATIC NET PC Software version.