Siemens SIMATIC ET 200PA SMART 6ES7650-8AR60-1AA0 AI 8 TC/4 RTD Module

Manufacturer: Siemens
Condition: Brand New
Lead Time: In Stock
Origin: Germany
Warranty: 12 Months

  • Overview
  • Hot Selling Models
  • Recommended Products
Overview

Siemens · SIMATIC ET 200PA SMART

6ES7650-8AR60-1AA0 AI 8 x TC/4 x RTD Conformal-Coated Analog Input Module

Siemens 6ES7650-8AR60-1AA0 is the protective-coated execution of the SIMATIC ET 200PA SMART AI 8 x TC/4 x RTD analog input module. It accepts thermocouple, resistance, resistance-thermometer and voltage measurements in four parameter groups, with selectable resolution, interference suppression and diagnostic behavior.

At a Glance

Brand Siemens
Model 6ES7650-8AR60-1AA0
Product Type Conformal-Coated Temperature Analog Input Module
Core Function Provides configurable grouped acquisition with channel diagnostics
Application or Compatible Series SIMATIC ET 200PA SMART process I/O stations

Exact Coated Variant

Match the complete -1AA0 suffix because it identifies the conformal-coated execution rather than the standard -0AA0 module.

Channel-Group Planning

Configure channels in fixed pairs and reserve channels 0, 2, 4 and 6 when four RTD measurements are required.

Signal and Noise Setup

Select the measuring range, integration time and interference-frequency suppression for each channel group before commissioning.

Product Overview

Siemens 6ES7650-8AR60-1AA0 is the protective-coated execution of the SIMATIC ET 200PA SMART AI 8 x TC/4 x RTD analog input module. It accepts thermocouple, resistance, resistance-thermometer and voltage measurements in four parameter groups, with selectable resolution, interference suppression and diagnostic behavior.

Handles thermocouple, thermal-resistance, resistance and voltage measurements and allows mixed TC and RTD use in one module. Offers three resolution and integration-time combinations so conversion speed can be balanced against noise rejection. Provides configurable diagnostics, diagnostic interrupts and wire-break supervision for field troubleshooting.

Ordering focus: Confirm the full -1AA0 coated article number, the required TC and RTD channel mix, every paired-channel parameter, input addressing and the installed ET 200PA SMART hardware configuration before ordering..

Key Functions

Flexible Temperature Acquisition

Handles thermocouple, thermal-resistance, resistance and voltage measurements and allows mixed TC and RTD use in one module.

Selectable Conversion Performance

Offers three resolution and integration-time combinations so conversion speed can be balanced against noise rejection.

Channel Diagnostics

Provides configurable diagnostics, diagnostic interrupts and wire-break supervision for field troubleshooting.

Official Specifications

Input Architecture 8 inputs arranged in 4 channel groups
Channel-Group Assignment CH0/CH1, CH2/CH3, CH4/CH5 and CH6/CH7
Parameter Scope Measurement parameters apply to both channels in the selected group
Selectable Resolution 9 bits + sign, 12 bits + sign or 15 bits + sign
Conversion Profiles 2.5 ms at 400 Hz; 16.67/20 ms at 60/50 Hz; 100 ms at 10 Hz
Measurement Selection Voltage, resistance, thermal resistance or thermocouple by channel group
Measuring-Range Selection User-selectable for every channel group
RTD Channel Positions CH0, CH2, CH4 and CH6 for four RTD signals
RTD Address Spacing Two-byte gaps between the active RTD channel addresses
Mixed-Signal Configuration Thermocouple and RTD measurements can be combined within one module
Diagnostic Configuration Channel diagnostics are parameterizable
Diagnostic Interrupt Parameterizable at module level
Wire-Break Supervision Configurable for the measurement ranges defined by the module
CPU Isolation Analog input circuits are electrically isolated from the CPU
Channel Common-Mode Limit Less than 60 V between channels
Product Version Baseline Supported from product version 01
Approximate Dimensions 40 x 125 x 117 mm (W x H x D)
Approximate Weight 250 g

Frequently Asked Questions

Can 6ES7650-8AR60-1AA0 measure thermocouples and RTDs in the same station?

Yes, mixed TC and RTD operation is possible when each fixed channel group is parameterized for its connected signal.

Which channels should carry RTDs on 6ES7650-8AR60-1AA0?

Use channels 0, 2, 4 and 6 and preserve the two-byte gaps in the address layout.

How do I choose the conversion setting for 6ES7650-8AR60-1AA0?

Select 400, 60, 50 or 10 Hz interference suppression according to the required balance between response time and noise rejection.

Does 6ES7650-8AR60-1AA0 allow independent settings on every channel?

Settings are applied by channel group, so each paired channel set shares its measurement parameters.

What should I check for wire-break diagnostics on 6ES7650-8AR60-1AA0?

Enable the wire-break check for the chosen range and confirm that the installed sensor circuit matches the configured measurement type.

Can I replace a -0AA0 module directly with 6ES7650-8AR60-1AA0?

The electrical function is the coated counterpart, but the exact hardware configuration, channel assignment and project catalog entry must still be verified.

What project data should I preserve before exchanging 6ES7650-8AR60-1AA0?

Record every channel-group range, interference setting, diagnostic enable and input address before removal.

Compatibility & Ordering Notes

Before ordering 6ES7650-8AR60-1AA0: Confirm the full -1AA0 coated article number, the required TC and RTD channel mix, every paired-channel parameter, input addressing and the installed ET 200PA SMART hardware configuration before ordering..

Compatibility Checklist

  • Confirm an ET 200PA SMART station and the matching interface and bus-module arrangement.
  • Match the complete -1AA0 coated suffix rather than the standard -0AA0 execution.
  • Verify the fixed CH0/1, CH2/3, CH4/5 and CH6/7 grouping in the saved project.
  • Use CH0, CH2, CH4 and CH6 for RTDs and retain the documented address gaps.
  • Match each sensor type and measuring range to its configured channel group.
  • Restore the selected interference suppression, diagnostic interrupts and wire-break settings.
  • Check terminal wiring, shielding and the plant potential-difference limits before energizing.
Hot Selling Models
P1DILEM
7000-40321-6530500
Z1-57
CH10.A221-600.FT2
A620/5 GHG 127 0000 A 9101
II5742 IIK3015BBPKG/US
7DM465.7 DM465
ZB5 AZ103
3RT2024-1AB00
IN3002LBPOG
XVBC4B8 084517
P1533B016001
SK3105000
VDE0435 OIH3W