Siemens SIMADYN D 6DD1688-0AE2 SS52 PROFIBUS-DP Communication Module
Manufacturer: Siemens
Condition: Brand New
Lead Time: In Stock
Origin: Germany
Warranty: 12 Months
Email: [email protected]
whatsApp: +86-18150117685
- Overview
- Hot Selling Models
- Recommended Products
Overview
- Use only with a supported SIMADYN D station and CS7 carrier.
- Keep the number of communication modules within the carrier limit.
- Preserve the configured PROFIBUS master or slave role and station address.
- Verify the isolated RS 485 cable, connector and termination arrangement.
- Retain SYNC, FREEZE and shared-input settings where used.
- Back up the COM PROFIBUS project and dual-port-memory data mapping.
- Confirm the separate MPI or optical-link wiring when those functions are installed.
Siemens · SIMADYN D
6DD1688-0AE2 SS52 PROFIBUS-DP Communication Module
Siemens 6DD1688-0AE2 is the SIMADYN D SS52 communications module for PROFIBUS-DP and MPI connectivity. It plugs into a CS7 carrier and exchanges controller data through the carrier module dual-port memory.
At a Glance
| Brand | Siemens |
|---|---|
| Model | 6DD1688-0AE2 |
| Product Type | SIMADYN D PROFIBUS Communication Module |
| Core Function | Links a SIMADYN D station to PROFIBUS-DP as a master or slave |
| Application or Compatible Series | SIMADYN D systems using a CS7 carrier module |
Exact Module Identity
Confirm the SS52 article number and the installed CS7 carrier before replacement.
Bus Configuration
Preserve the PROFIBUS address, master or slave role, baud rate, termination and configured SYNC or FREEZE behavior.
Service Connection
Retain the X5 cabling for isolated RS 485 communication and the RS 232 parameterization path used by the project.
Product Overview
Siemens 6DD1688-0AE2 is the SIMADYN D SS52 communications module for PROFIBUS-DP and MPI connectivity. It plugs into a CS7 carrier and exchanges controller data through the carrier module dual-port memory.
Operates on PROFIBUS-DP in either master or slave configurations. Supports shared-input, SYNC and FREEZE functions for coordinated process-data transfer. Uses the CS7 dual-port memory to exchange data with the SIMADYN D processor.
Key Functions
Master and Slave Communication
Operates on PROFIBUS-DP in either master or slave configurations.
Deterministic Data Exchange
Supports shared-input, SYNC and FREEZE functions for coordinated process-data transfer.
Carrier-Based Integration
Uses the CS7 dual-port memory to exchange data with the SIMADYN D processor.
Official Specifications
| Communication System | PROFIBUS-DP / SINEC L2-DP |
|---|---|
| PROFIBUS Roles | Master or slave |
| Additional Interface | MPI for SIMATIC S7 and M7 communication |
| Supported Coordination Functions | Shared input, SYNC and FREEZE |
| Carrier Module | CS7 |
| Maximum Communication Modules per CS7 | 3 |
| Controller Data Exchange | 16 KB dual-port RAM on the CS7 carrier |
| PROFIBUS Electrical Interface | Isolated RS 485 at connector X5 |
| Service Interface | RS 232 for COM PROFIBUS parameterization and diagnostics |
| Optical Link Supply | Isolated 5 V supply available for an optical link module |
Frequently Asked Questions
Can 6DD1688-0AE2 operate as a PROFIBUS master?
Yes, the module can be configured for either master or slave operation.
Which carrier is required for 6DD1688-0AE2?
Install it in a CS7 carrier and verify that the available communication-module position is supported.
How does 6DD1688-0AE2 exchange data with the controller?
Process data is transferred through the 16 KB dual-port memory on the carrier module.
Can 6DD1688-0AE2 use an optical PROFIBUS link?
Yes, the interface provides an isolated 5 V supply intended for a suitable optical link module.
Which connector carries PROFIBUS on 6DD1688-0AE2?
Use the isolated RS 485 connection at X5 and preserve the project cable and termination arrangement.
How should I parameterize 6DD1688-0AE2 during commissioning?
Use the RS 232 service connection with COM PROFIBUS and restore the saved bus configuration.
What must be backed up before replacing 6DD1688-0AE2?
Save the station project, master or slave role, address, baud rate, data mapping and synchronization settings.