Overview
SIMATIC ET 200S FC

6SL3244-0SA01-1AA0 ET 200S FC ICU24F Inverter Control Module

ICU24F module with STOP 0, STOP 1 and safely reduced speed, motor-temperature inputs and HTL encoder evaluation for the original ET 200S FC drive assembly.

At a Glance

Brand Siemens
Model 6SL3244-0SA01-1AA0
Product Type Fail-safe frequency-converter control module
Core Function Controls IPM25 and evaluates safety shutdown groups
Application Decentralized ET 200S motor-control assemblies

Original ICU24F safety functions

The control module supports STOP 0 safe halt, STOP 1 safe braking ramp and safely reduced speed.

Motor regulation and monitoring

The control module evaluates motor-temperature and HTL speed-feedback signals while commanding the IPM25 power section.

Stored parameters and diagnostics

The module supports MMC-PS parameter transfer, STARTER commissioning over RS232 and front-panel status indication.

Product Overview

6SL3244-0SA01-1AA0 is an ICU24F control module for the original ET 200S FC converter assembly. Together with the associated IPM25 power module, it forms a distributed converter integrated into the ET 200S station.

This revision provides safe halt, safe braking ramp and safely reduced speed functions. The module also manages motor regulation, temperature monitoring, parameter storage and station diagnostics through its dedicated control and feedback interfaces.

Ordering focus: Match the original ICU24F revision, configured safety groups and parameter set to the installed ET 200S FC assembly, and retain the correct TM-ICU15/IPM25 combination.
Key Functions

Original ICU24F safety functions

The control module supports STOP 0 safe halt, STOP 1 safe braking ramp and safely reduced speed.

Motor regulation and monitoring

The control module evaluates motor-temperature and HTL speed-feedback signals while commanding the IPM25 power section.

Stored parameters and diagnostics

The module supports MMC-PS parameter transfer, STARTER commissioning over RS232 and front-panel status indication.

Official Specifications
Current demand 0.8 A maximum; 0.4 A typical
Installed dimensions (W × H × D) 15 × 220 × 156 mm, including terminal-module depth
Module weight Approximately 250 g
Ambient temperature −10 to +60 °C horizontal; −10 to +40 °C vertical installation
Protection rating IP20
Maximum safety classes SIL 2, IEC 61508; Category 3, EN 954-1
PFH 1.46 × 10⁻7 per hour
Specified service life 10 years
Setpoint and output-frequency resolution 0.01 Hz digital; 0.01 Hz serial
Motor-temperature sensing PTC or KTY84 interface
Speed-encoder interface HTL encoder, 24 V output supply, maximum 200 mA
Serial commissioning port RS232 for PC connection with STARTER
Parameter storage interface MMC-PS slot, with parameter upload/download
Safety shutdown groups G1–G6
Front-panel indicators 10 LEDs: SF, RY, SH, OL and G1–G6
Frequently Asked Questions

Which safety functions are documented for 6SL3244-0SA01-1AA0?

The supported functions are STOP 0 safe halt, STOP 1 safe braking ramp and safely reduced speed.

May standard and fail-safe units share the potential group containing 6SL3244-0SA01-1AA0?

Standard and fail-safe potential groups may coexist in one station, but their modules must not be mixed within one potential group.

What does the SH indicator on 6SL3244-0SA01-1AA0 show?

The SH LED identifies safe halt, while SH and OL together indicate safely reduced speed.

How does 6SL3244-0SA01-1AA0 exchange data with the IM151?

The backplane bus connects the control module to the station interface module.

Can 6SL3244-0SA01-1AA0 read parameters from an MMC-PS?

The drive can be configured to read its parameter settings from MMC-PS or from the control module EEPROM.

What motor-temperature sensors can 6SL3244-0SA01-1AA0 accept?

The temperature interface supports a PTC sensor or KTY84 sensor.

Does changing 6SL3244-0SA01-1AA0 to a standard ICU24 preserve the specified safety hardware?

No; a fail-safe ICU24F must not be exchanged for a standard ICU24.

Compatibility & Ordering Notes
Before ordering 6SL3244-0SA01-1AA0: Match the original ICU24F revision, configured safety groups and parameter set to the installed ET 200S FC assembly, and retain the correct TM-ICU15/IPM25 combination.

Before installation

  • Check the existing order number and original revision before choosing a replacement or transferring parameters.
  • Mount the module on TM-ICU15, retain the associated IPM25 connection and keep the fail-safe potential-group arrangement.
  • Include the maximum 0.8 A control-module demand and all other loads in the 24 V group calculation.
  • Use the original connector assignments and complete drive and machine safety commissioning after installation.
Hot Selling Models
676210 - 4000-67000-0676210
64087000
VR15SB11AV313A
FAZ-K40/3 278915 + FAZ-XHIN11
0820 024 080
NZ2HS-2131
1200658972
Allen-Bradley 100-C16E*10
5SH318
3RV2011-4AA25
PRMY-5-1/8-6
BL49-25BG
SC-0Y/G 4GC0F0M10Y
6EC1652-3A
3RV2 011-1FA25

Get a Free Quote

Our representative will contact you soon.
Email
Name
Company Name
Message
0/1000
email goToTop

Evolo Automation is not an authorized distributor unless otherwise specified, representative, or affiliate of the manufacturer of this product. All trademarks and documents are the property of their respective owners and are provided for identification and informational.