Siemens 6SL3244-0SA01-1AA0 ET 200S FC ICU24F Inverter Control Module
Manufacturer: Siemens
Condition: Brand New
Lead Time: In Stock
Origin: Germany
Warranty: 12 Months
Email: [email protected]
whatsApp: +86-18150117685
- Overview
- Hot Selling Models
- Recommended Products
Overview
- Check the existing order number and original revision before choosing a replacement or transferring parameters.
- Mount the module on TM-ICU15, retain the associated IPM25 connection and keep the fail-safe potential-group arrangement.
- Include the maximum 0.8 A control-module demand and all other loads in the 24 V group calculation.
- Use the original connector assignments and complete drive and machine safety commissioning after installation.
6SL3244-0SA01-1AA0 ET 200S FC ICU24F Inverter Control Module
ICU24F module with STOP 0, STOP 1 and safely reduced speed, motor-temperature inputs and HTL encoder evaluation for the original ET 200S FC drive assembly.
At a Glance
| Brand | Siemens |
|---|---|
| Model | 6SL3244-0SA01-1AA0 |
| Product Type | Fail-safe frequency-converter control module |
| Core Function | Controls IPM25 and evaluates safety shutdown groups |
| Application | Decentralized ET 200S motor-control assemblies |
Original ICU24F safety functions
The control module supports STOP 0 safe halt, STOP 1 safe braking ramp and safely reduced speed.
Motor regulation and monitoring
The control module evaluates motor-temperature and HTL speed-feedback signals while commanding the IPM25 power section.
Stored parameters and diagnostics
The module supports MMC-PS parameter transfer, STARTER commissioning over RS232 and front-panel status indication.
Product Overview
6SL3244-0SA01-1AA0 is an ICU24F control module for the original ET 200S FC converter assembly. Together with the associated IPM25 power module, it forms a distributed converter integrated into the ET 200S station.
This revision provides safe halt, safe braking ramp and safely reduced speed functions. The module also manages motor regulation, temperature monitoring, parameter storage and station diagnostics through its dedicated control and feedback interfaces.
Key Functions
Original ICU24F safety functions
The control module supports STOP 0 safe halt, STOP 1 safe braking ramp and safely reduced speed.
Motor regulation and monitoring
The control module evaluates motor-temperature and HTL speed-feedback signals while commanding the IPM25 power section.
Stored parameters and diagnostics
The module supports MMC-PS parameter transfer, STARTER commissioning over RS232 and front-panel status indication.
Official Specifications
| Current demand | 0.8 A maximum; 0.4 A typical |
|---|---|
| Installed dimensions (W × H × D) | 15 × 220 × 156 mm, including terminal-module depth |
| Module weight | Approximately 250 g |
| Ambient temperature | −10 to +60 °C horizontal; −10 to +40 °C vertical installation |
| Protection rating | IP20 |
| Maximum safety classes | SIL 2, IEC 61508; Category 3, EN 954-1 |
| PFH | 1.46 × 10⁻7 per hour |
| Specified service life | 10 years |
| Setpoint and output-frequency resolution | 0.01 Hz digital; 0.01 Hz serial |
| Motor-temperature sensing | PTC or KTY84 interface |
| Speed-encoder interface | HTL encoder, 24 V output supply, maximum 200 mA |
| Serial commissioning port | RS232 for PC connection with STARTER |
| Parameter storage interface | MMC-PS slot, with parameter upload/download |
| Safety shutdown groups | G1–G6 |
| Front-panel indicators | 10 LEDs: SF, RY, SH, OL and G1–G6 |
Frequently Asked Questions
Which safety functions are documented for 6SL3244-0SA01-1AA0?
The supported functions are STOP 0 safe halt, STOP 1 safe braking ramp and safely reduced speed.
May standard and fail-safe units share the potential group containing 6SL3244-0SA01-1AA0?
Standard and fail-safe potential groups may coexist in one station, but their modules must not be mixed within one potential group.
What does the SH indicator on 6SL3244-0SA01-1AA0 show?
The SH LED identifies safe halt, while SH and OL together indicate safely reduced speed.
How does 6SL3244-0SA01-1AA0 exchange data with the IM151?
The backplane bus connects the control module to the station interface module.
Can 6SL3244-0SA01-1AA0 read parameters from an MMC-PS?
The drive can be configured to read its parameter settings from MMC-PS or from the control module EEPROM.
What motor-temperature sensors can 6SL3244-0SA01-1AA0 accept?
The temperature interface supports a PTC sensor or KTY84 sensor.
Does changing 6SL3244-0SA01-1AA0 to a standard ICU24 preserve the specified safety hardware?
No; a fail-safe ICU24F must not be exchanged for a standard ICU24.