Siemens 6SL3210-5BE24-0UV0 SINAMICS V20 4 kW Three-Phase Inverter
Manufacturer: Siemens
Condition: Brand New
Lead Time: In Stock
Origin: Germany
Warranty: 12 Months
Email: [email protected]
whatsApp: +86-18150117685
- Overview
- Hot Selling Models
- Recommended Products
Overview
- Apply the IEC or NEC current rating appropriate to the installation.
- Provide external EMC filtering where required for this unfiltered variant.
- Account for the absence of an integrated braking chopper.
- Observe derating above 40 °C and the 25 m shielded or 50 m unshielded motor-cable limits.
6SL3210-5BE24-0UV0 SINAMICS V20 4 kW Three-Phase Inverter
The V20 inverter provides 4 kW output from a 380–480 V three-phase supply, with USS/Modbus RTU communication and configurable onboard I/O.
At a Glance
| Brand | Siemens |
|---|---|
| Model | 6SL3210-5BE24-0UV0 |
| Product Type | Variable-speed inverter |
| Core Function | AC motor speed control |
| Application | General-purpose machine drives |
4 kW power rating
The drive is rated at 8.8 A under IEC conditions and 8.2 A under the stated NEC voltage conditions.
Serial drive integration
USS and Modbus RTU connect the drive to a serial control network.
Unfiltered power unit
This variant has neither an integrated EMC filter nor an integrated braking chopper.
Product Overview
6SL3210-5BE24-0UV0 is a 4 kW SINAMICS V20 inverter for a three-phase 380–480 V supply. It provides motor speed control with output frequencies up to 550 Hz and USS/Modbus RTU communication.
The FSB housing uses an external cooling fan and provides four digital inputs, relay and transistor outputs, two analog inputs and one analog output for machine control integration.
Key Functions
Adjustable-frequency motor supply
The inverter produces a three-phase output with a frequency range from 0 to 550 Hz and a rated power of 4 kW.
Serial and local I/O control
USS/Modbus RTU and onboard digital and analog signals provide alternative ways to integrate speed commands and machine status.
Load and thermal management
The drive provides defined low- and high-overload duty cycles, with output derating required above 40 °C ambient temperature.
Official Specifications
| Input supply | 3 AC, 380–480 V; −15% / +10% tolerance |
|---|---|
| Input frequency | 47–63 Hz |
| Rated output power | 4 kW; 5 hp under NEC rating |
| Rated output current | 8.8 A IEC; 8.2 A NEC at 440–480 V |
| Output frequency | 0–550 Hz |
| Pulse frequency | 4 kHz |
| Overload duty | Low overload: 110% for 60 s per 300 s; high overload: 150% for 60 s per 300 s |
| Communication | USS / Modbus RTU |
| Digital I/O | 4 inputs; 1 relay changeover output and 1 transistor output |
| Analog I/O | 2 inputs, alternatively usable as digital inputs; 1 output |
| Integrated EMC filter and braking chopper | Neither is integrated |
| Efficiency | 98% |
| Maximum motor cable length | 25 m shielded; 50 m unshielded |
| Protection rating and frame | IP20 / UL open type; FSB |
| Cooling | External fan |
| Operating ambient | −10 to +60 °C; derating above 40 °C |
| Storage temperature | −40 to +70 °C |
| Installation altitude rating | 1000 m |
| Dimensions (W × H × D) | 140 × 160 × 164.5 mm |
| Net weight | 1.6 kg |
Frequently Asked Questions
Can I connect 6SL3210-5BE24-0UV0 directly to an Ethernet control network?
The integrated communication protocols are USS and Modbus RTU rather than Ethernet.
Does 6SL3210-5BE24-0UV0 include an EMC filter?
This drive variant is unfiltered, so any required EMC filtering must be provided separately.
Can I connect a braking resistor straight to an integrated chopper on 6SL3210-5BE24-0UV0?
The drive does not contain an integrated braking chopper.
Do I need to reduce the load on 6SL3210-5BE24-0UV0 above 40 °C?
The permitted operating range extends to 60 °C with derating required above 40 °C.
Which current rating of 6SL3210-5BE24-0UV0 applies to a 460 V NEC installation?
The NEC output current rating at 440–480 V is 8.2 A, compared with the 8.8 A IEC rating.
Can I use the analog inputs on 6SL3210-5BE24-0UV0 for additional digital signals?
The two analog inputs can alternatively be used as digital inputs.
How long can 6SL3210-5BE24-0UV0 supply 150% overload?
High-overload operation permits 150% for 60 seconds in each 300-second duty cycle.