- Connect both optical ports in the correct transmission direction.
- Keep every ring node powered during communication.
- Use external 24 V DC where host-off ring continuity is required.
- Reserve slot C for a sensor board when present and use another suitable slot for SLB.
6SE7090-0XX84-0FJ0 SIMOVERT MASTERDRIVES SLB SIMOLINK Board
The SLB board links MASTERDRIVES units into a fiber-optic SIMOLINK ring for data exchange and synchronization, with external 24 V DC supply support.
At a Glance
| Brand | Siemens |
|---|---|
| Model | 6SE7090-0XX84-0FJ0 |
| Product Type | Drive communication option board |
| Core Function | SIMOLINK drive data exchange |
| Application | Compatible MASTERDRIVES converters and inverters |
Optical ring link
SIMOLINK uses dedicated optical input and output connections.
Dispatcher or transceiver
Parameterization selects the board role in the ring.
External supply input
A 24 V DC supply can keep the ring node active while the converter is powered down.
Product Overview
6SE7090-0XX84-0FJ0 is the SLB SIMOLINK option board for compatible SIMOVERT MASTERDRIVES units. It exchanges drive data and synchronizes participating drives to a common system clock through a closed fiber-optic ring.
The board can operate as a dispatcher or transceiver, reads ring telegrams and stores selected data, while its external supply connection supports ring continuity when the host converter is powered down.
Key Functions
Synchronized drive communication
The SIMOLINK ring transfers data between participating drives and provides a common system clock for synchronization.
Selectable node role
Parameterization selects dispatcher or transceiver operation, with up to 201 nodes permitted on the ring.
Power continuity and diagnostics
The external 24 V DC feed supports operation independently of host converter power, and three LEDs indicate the board operating state.
Official Specifications
| Data transfer rate | 11 MBaud |
|---|---|
| Maximum ring size | 201 nodes |
| Internal supply requirement | 5 V DC, maximum 600 mA |
| External supply requirement | 24 V DC, maximum 200 mA |
| Maximum plastic-fiber node spacing | 40 m |
| Maximum glass-fiber node spacing | 300 m |
| Maximum propagation delay | 3 clock times |
| Board size (length × width) | 90 × 83 mm |
| Cooling | Natural-air cooling |
| Operating temperature | 0 to 70 °C |
| Storage and transport temperature | −25 to +70 °C |
| Relative humidity | Maximum 85% in operation; 95% in storage and transport; no condensation |
| Pollution degree | 2 |
| Operating climate class | 3K3 according to DIN IEC 721-3-3 |
Frequently Asked Questions
Must I connect both optical ports on 6SE7090-0XX84-0FJ0?
Both the optical input and optical output must be connected to complete the closed SIMOLINK ring.
Which optical connector is the input on 6SE7090-0XX84-0FJ0?
The lower dark-gray connection is the input and the upper light-gray connection is the output.
Can 6SE7090-0XX84-0FJ0 keep the ring running when the host converter is off?
An external 24 V DC supply keeps the board operating so ring data transfer can continue with the converter powered down.
Can I remove the external supply from 6SE7090-0XX84-0FJ0 during normal ring operation?
Removing the external supply during bus operation is not permitted because the supply changeover resets the board and loses telegrams.
How do I select dispatcher or transceiver operation on 6SE7090-0XX84-0FJ0?
The operating role is selected through parameterization.
Can I use a 100 m plastic-fiber span between 6SE7090-0XX84-0FJ0 and the next node?
Plastic fiber is limited to 40 m between nodes, while glass fiber permits up to 300 m.
Can I install 6SE7090-0XX84-0FJ0 in slot C when a sensor board already needs that slot?
The sensor board requires slot C, so the SIMOLINK board must use another suitable option slot.